Page 2 - Have questions or need assistance?; Product Info & Updates; Call our Customer Care Team Toll-Free at:; AN IMPORTANT MESSAGE ABOUT TEMPERATURE:
*We are always working to improve our products. Therefore, the enclosed product may differ slightly from the image on the cover. Have questions or need assistance? Do not return this product to the store ! WE ARE HERE TO HELP! Visit our website: www.championpowerequipment.com for more info: s Produc...
Page 3 - TABLE OF CONTENTS; Electric Start; PORTABLE GENERATOR
41430 TABLE OF CONTENTS Introduction 1 Introduction 1 Portable Power Generator 1 Accessories 1 This Booklet 1 Manual Conventions 2 Safety Rules 3 Controls and Features 5 Generator 5 Power Panel 6 Parts Included 7 Wheel Kit 7 Other 7 Assembly 8 Remove the Generator from the Shipping Carton 8 Install ...
Page 4 - ENGLISH; Introduction; Model Number; INTRODUCTION
1 REV 41430-20130527 ENGLISH 41430 Introduction Congratulations on your purchase of a Champion Power Equipment generator. CPE designs and builds generators to strict specifications. With proper use and maintenance, this generator will bring years of satisfying service. Portable Power Generator This ...
Page 5 - MANUAL CONVENTIONS; CAUTION; CAUTION; DANGER; WARNING
REV 41430-20130527 2 41430 ENGLISH MANUAL CONVENTIONS This manual uses the following symbols to help differentiate between different kinds of information. The safety symbol is used with a key word to alert you to potential hazards in operating and owning power equipment.Follow all safety messages to...
Page 6 - SAFETY RULES; When servicing the generator:
3 REV 41430-20130527 ENGLISH 41430 SAFETY RULES Generator exhaust contains carbon monoxide, a colorless, odorless, poison gas. Breathing carbon monoxide will cause nausea, dizziness, fainting or death. If you start to feel dizzy or weak, get to fresh air immediately. Operate generator outdoors only ...
Page 7 - When adding or removing fuel :
REV 41430-20130527 4 41430 ENGLISH SAFETY RULES Improper treatment or use of the generator can damage it, shorten its life and void your warranty. Use the generator only for intended uses.Operate only on level surfaces.DO NOT expose generator to excessive moisture, dust, or dirt.DO NOT allow any mat...
Page 8 - Generator; CONTROLS AND FEATURES
5 REV 41430-20130527 ENGLISH 41430 Read this owner’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference. (1) Fuel Tank – 5.7 gallon (21.5 L) capacity fuel tank. (2) Choke – Controls choke val...
Page 9 - Power Panel
REV 41430-20130527 6 41430 ENGLISH Power Panel 3 CONTROLS AND FEATURES 1 5 7 4 (1) Ignition Switch – Used to start or stop the generator. (2) Intelligauge™ – Three mode digital meter for displaying running hours, voltage and hertz. (3) Circuit Breakers – Protects the generator against electrical ove...
Page 10 - Parts Included; Wheel Kit; Other
7 REV 41430-20130527 ENGLISH 41430 Parts Included Your 41430 Gasoline Powered Generator ships with the following parts: Wheel Kit – 10 in. Wheel 2 – Pin Roll (16x100 for wheel) 2 – Garter Spring B (for wheel) 2 – Handle 1 – Pin Roll (8x45 for handle) 2 – Garter Spring B (for handle) 2 – Support Leg ...
Page 11 - ASSEMBLY; Remove the Generator from the Shipping Carton; Install the Wheel Kit; Install the Support Leg; Install the Handle; Connect the Battery
REV 41430-20130527 8 41430 ENGLISH ASSEMBLY Your generator requires some assembly. This unit ships from our factory without oil. It must be properly serviced with fuel and oil before operation.If you have any questions regarding the assembly of your generator, call our help line at 1-877-338-0999. P...
Page 12 - Add Engine Oil; NOTE; Add Engine Oil Cont’d.
9 REV 41430-20130527 ENGLISH 41430 1. Place the generator on a flat, level surface. 2. Remove oil fill cap /dipstick to add oil.3. Add 1.16 qt. (1.1 L) of oil (included) and replace oil fill cap/dipstick. DO NOT OVERFILL. 4. Check engine oil level daily and add as needed. The recommended oil type is...
Page 13 - Grounding; Add Fuel
REV 41430-20130527 10 41430 ENGLISH ASSEMBLY Add Fuel Cont’d. Grounding Your generator must be properly connected to an appropriate ground to help prevent electric shock. A ground terminal connected to the frame of the generator has been provided on the power panel. For remote grounding, connect of ...
Page 14 - OPERATION; Generator Location; Surge Protection
11 REV 41430-20130527 ENGLISH 41430 OPERATION Generator Location NEVER operate the generator inside any building, including garages, basements, crawlspaces and sheds, enclosure or compartment, including the generator compartment of a recreational vehicle. Please consult your local authority. In some...
Page 15 - Connecting Electrical Loads; Starting the Engine
REV 41430-20130527 12 41430 ENGLISH Connecting Electrical Loads 1. Let the engine stabilize and warm up for a few minutes after starting 2. Plug in and turn on the desired 120/240 Volt AC single phase, 60 Hz electrical loads. – DO NOT connect 3-phase loads to the generator. – DO NOT connect 50 Hz lo...
Page 16 - Do Not Overload Generator; Capacity; Stopping the Engine
13 REV 41430-20130527 ENGLISH 41430 Do Not Overload Generator Capacity Follow these simple steps to calculate the running and starting watts necessary for your purposes. 1. Select the electrical devices you plan on running at the same time. 2. Total the running watts of these items. This is the amou...
Page 17 - Engine Maintenance; Oil; MAINTENANCE AND STORAGE
REV 41430-20130527 14 41430 ENGLISH The owner/operator is responsible for all periodic maintenance. Complete all scheduled maintenance in a timely manner. Correct any issue before operating the generator. Never operate a damaged or defective generator. Tampering with the factory set governor will vo...
Page 18 - Adjustments; Spark Arrester; Generator Maintenance
15 REV 41430-20130527 ENGLISH 41430 Adjustments The air-fuel mixture is not adjustable. Tampering with the governor can damage your generator and your electrical devices and will void your warranty. CPE recommends that you contact our service line at 1-877-338-0999 for all other service and/or adjus...
Page 19 - Storage; Generator Storage; Battery; Disconnect the Battery; Charge the Battery
REV 41430-20130527 16 41430 ENGLISH MAINTENANCE AND STORAGE Storage The generator should be started at least once every 14 days and allowed to run for at least 20 minutes. For longer term storage, please follow these guidelines. Generator Storage 1. Add a properly formulated fuel stabilizer to the t...
Page 20 - SPECIFICATIONS
17 REV 41430-20130527 ENGLISH 41430 Fuel Fuel capacity is 5.7 gallons (21.5 L). Use regular unleaded gasoline with a minimum octane rating of 85 and an ethanol content of less than 10% by volume. Generator Specifications – Model 41430 – Running Wattage 7500 Watts – Starting Wattage 9375 Watts – AC L...
Page 21 - Wiring Diagram
REV 41430-20130527 18 41430 ENGLISH Wiring Diagram SPECIFICATIONS
Page 22 - Parts Diagram
19 REV 41430-20130527 ENGLISH 41430 SPECIFICATIONS Parts Diagram
Page 23 - Parts List
REV 41430-20130527 20 41430 ENGLISH Parts List # Part Number Description Qty 1 TD6120-C03-0002 Fuel Tank Cap 1 2 B057890006002570B Flange Bolt M6 × 25 4 3 91302-9065202500B Washer Ø6.5 × 2 × Ø25 4 4 TD6130-B98-0200 Fuel Level Indication 1 5 TD6100-H59-0001CK Fuel Tank 1 6 TD6040-B93-0101 Fuel Cock 1...
Page 24 - Engine Parts Diagram
21 REV 41430-20130527 ENGLISH 41430 SPECIFICATIONS Engine Parts Diagram
Page 26 - TROUBLESHOOTING; For further technical support :
23 REV 41430-20130527 ENGLISH 41430 TROUBLESHOOTING For further technical support : Technical Service Mon – Fri 8:30 AM – 5:00 PM (PST/PDT)Toll Free: 1-877-338-0999tech@ championpowerequipment.com Problem Cause Solution Generator will not start No fuel Add fuel Faulty spark plug Replace spark plug U...
Page 27 - WARRANTY; Installation, Use and Maintenance Cont’d.
REV 41430-20130527 24 41430 ENGLISH WARRANTY WARRANT Y CHAMPION POWER EQUIPMENT 2 YEAR LIMITED WARRANTY Warranty Qualifications Champion Power Equipment (CPE) will register this warranty upon receipt of your Warranty Registration Card and a copy of your sales receipt from one of CPE’s retail locatio...