Page 2 - Have questions or need assistance?; Call our Customer Care Team Toll-Free at:; AN IMPORTANT MESSAGE ABOUT TEMPERATURE:; to cause cancer, birth defects or other reproductive harm.
*We are always working to improve our products. Therefore, the enclosed product may differ slightly from the image on the cover. Have questions or need assistance? Do not return this product to the store ! WE ARE HERE TO HELP! Visit our website: www.championpowerequipment.com for more info: • Produc...
Page 3 - TABLE OF CONTENTS; Electric Start; DUAL FUEL GENERATOR
100153 TABLE OF CONTENTS Introduction 1 Introduction 1 Portable Power Generator 1 Accessories 1 This Booklet 1 Manual Conventions 2 Safety Rules 3 Fuel Safety 5 Controls and Features 6 Generator 6 Generator Panel 7 Parts Included 8 Wheel Kit 8 Other 8 Assembly 9 Remove the Generator from the Shippin...
Page 4 - ENGLISH; Introduction; Model Number; INTRODUCTION
1 ENGLISH 100153 Introduction Congratulations on your purchase of a Champion Power Equipment generator. CPE designs and builds generators to strict specifications. With proper use and maintenance, this generator will bring years of satisfying service. Portable Power Generator This unit is a gasoline...
Page 5 - MANUAL CONVENTIONS; CAUTION; CAUTION; DANGER; WARNING
2 100153 ENGLISH MANUAL CONVENTIONS This manual uses the following symbols to help differentiate between different kinds of information. The safety symbol is used with a key word to alert you to potential hazards in operating and owning power equipment.Follow all safety messages to avoid or reduce t...
Page 6 - SAFETy RULES; When servicing the generator:
3 ENGLISH 100153 SAFETy RULES Generator exhaust contains carbon monoxide, a colorless, odorless, poison gas. Breathing carbon monoxide will cause nausea, dizziness, fainting or death. If you start to feel dizzy or weak, get to fresh air immediately. Operate generator outdoors only in a well ventilat...
Page 8 - When adding or removing Gasoline :
5 ENGLISH 100153 Gasoline and Gasoline Vapors (Gas) : – GASOLINE IS HIGHLY FLAMMABLE AND ExPLOSIVE. – Gasoline can cause a fire or explosion if ignited. – Gasoline is a liquid fuel but it’s vapors can ignite. – Gasoline is a skin irritant and needs to be cleaned up immediately if spilled on skin or ...
Page 9 - Generator; CONTROLS AND FEATURES
6 100153 ENGLISH Read this owner’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference. Generator CONTROLS AND FEATURES 1 4 5 3 2 8 7 6 9 10 (1) Gas Fuel Tank – 6.1 gallon (23 L) capacity fuel...
Page 10 - Generator Panel
7 ENGLISH 100153 Generator Panel 1 2 3 4 5 8 7 6 9 11 10 (1) Fuel Selector Switch – Used to select and turn on gasoline or LPG fuel source. (2) Ignition Switch – Used to start or stop the generator. (3) Intelligauge – Three mode digital meter for displaying running hours, voltage and hertz. (4) Batt...
Page 11 - Parts Included; Wheel Kit
8 100153 ENGLISH Parts Included Your 100153 dual fuel generator ships with the following parts: Wheel Kit – 9.5 in. (24.1 cm) Wheel 2 – Flange Bolt (M10x120 for Wheel) 2 – Bushing 2 – Flat Washer ø10 2 – Lock Nut (M10) 2 – Support Leg w/ Vibration Mounts 1 – Flange Bolt (M8x16 for Support Leg) 2 – F...
Page 12 - ASSEMBLy; Remove the Generator from the Shipping Carton; Install the Wheel Kit; Connect the Battery
9 ENGLISH 100153 ASSEMBLy Your generator requires some assembly. This unit ships from our factory without oil. It must be properly serviced with fuel and oil before operation.If you have any questions regarding the assembly of your generator, call our help line at 1-877-338-0999. Please have your se...
Page 13 - Add Engine Oil; Add Engine Oil Cont’d.
10 100153 ENGLISH Add Engine Oil ASSEMBLy Add Engine Oil Cont’d. 1. Place the generator on a fl at, level surface. 2. Remove oil fi ll cap /dipstick to add oil.3. Add up to 1.2 qt. (1.1 L) of oil (included) and replace oil fi ll cap/dipstick. DO NOT OVERFILL. 4. Check engine oil level daily and add ...
Page 14 - NOTE
11 ENGLISH 100153 ASSEMBLy Add Fuel (Gasoline) Cont’d. Our engines work well with 10% or less ethanol blend fuels. When using blended fuels there are some issues worth noting: – Ethanol-gasoline blends can absorb more water than gasoline alone. – These blends can eventually separate, leaving water o...
Page 15 - Connecting LPG Cylinder Cont’d.; Grounding; Connecting Liquid Petroleum Gas (LPG) Cylinder
12 100153 ENGLISH ASSEMBLy Do not allow children to tamper or play with the cylinder or hose connections. CAUTION Use approved LPG cylinders equipped with an OPD (overfilling prevention device) valve. Always keep the cylinder in a vertical position with the valve on top and installed at ground level...
Page 16 - OPERATION; Generator Location; Surge Protection
13 ENGLISH 100153 OPERATION Generator Location NEVER operate the generator inside any building, including garages, basements, crawlspaces and sheds, enclosure or compartment, including the generator compartment of a recreational vehicle. Please consult your local authority. In some areas, generators...
Page 17 - Fuel Selector Switch; Gasoline
14 100153 ENGLISH OPERATION The fuel selector switch cover is specifically designed not to slide to either side while a specific fuel has been selected and the valve is in the “ON” position. Only when the fuel valves are in the “OFF” position can the cover slide side to side. NOTE The fuel selector ...
Page 18 - Starting the Engine Cont’d.
15 ENGLISH 100153 OPERATION If the engine starts but does not run make certain that the generator is on a flat, level surface. The engine is equipped with a low oil sensor that will prevent the engine from running when the oil level falls below a critical threshold. NOTE When the battery switch is i...
Page 19 - GFCI; Stopping the Engine
16 100153 ENGLISH OPERATION GFCI Your generator is equipped with two (2) Ground Fault Circuit Interrupter (GFCI) duplexes. In the event of a ground fault, a GFCI trips automatically to stop the flow of electricity and prevent serious injury. The green indicating light on the receptable will also tur...
Page 20 - Operation at High Altitude; Do Not Overload Generator; Capacity; Power Management
17 ENGLISH 100153 Operation using the alternative main jet at elevations lower than the recommended minimum altitude can damage the engine. For operation at lower elevations, the standard main jet must be used. Operating the engine with the wrong engine configuration at a given altitude may increase...
Page 21 - Air Filter; MAINTENANCE AND STORAGE; Engine Maintenance; Oil
18 100153 ENGLISH The owner/operator is responsible for all periodic maintenance. Complete all scheduled maintenance in a timely manner. Correct any issue before operating the generator. Never operate a damaged or defective generator. Tampering with the factory set governor will void your warranty. ...
Page 22 - Adjustments; Maintenance Schedule; Cleaning; Spark Arrester; Generator Maintenance
19 ENGLISH 100153 Adjustments The air-fuel mixture is not adjustable. Tampering with the governor can damage your generator and your electrical devices and will void your warranty. CPE recommends that you contact our service line at 1-877-338-0999 for all other service and/or adjustment needs. Maint...
Page 23 - Generator Storage; Generator Battery; Disconnect the Battery; Charge the Battery
20 100153 ENGLISH MAINTENANCE AND STORAGE Storage The generator should be started at least once every 14 days and allowed to run for at least 20 minutes. For longer term storage, please follow these guidelines. Generator Storage 1. Add a properly formulated fuel stabilizer to the tank.2. Be sure all...
Page 24 - SPECIFICATIONS
21 ENGLISH 100153 Oil Use 10W-30 automotive oil.Oil capacity is up to 1.2 qt. (1.1 L). DO NOT OVERFILL.Please reference the following chart for recommended oil types for use in the generator. Fuel Fuel (Gasoline) capacity is 6.1 gal. (23 L). – Use regular unleaded gasoline with a minimum octane rati...
Page 25 - Wiring Diagram; AVR
22 100153 ENGLISH Wiring Diagram SPECIFICATIONS B Y E N GI N E BLO C K GENERA TO R BLO C K SPARKING P LU G IG N IT IO N C OI L O IL L E VE L S W CONTROL BOX B LO C K COMBINA TI O N S W M W B BATTE R Y S TAR TE R R B 3 4 2 1 6 5 OF F O N S T COMBINATIO N S W IT C H 6 5 4 3 2 1 B/ W B/ W S T O N FU SE...
Page 26 - Parts Diagram
23 ENGLISH 100153 SPECIFICATIONS Parts Diagram 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 34 39 40 41 33 34 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 66 23 82 83 84 85 86 87 88 44 65 1 2 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 5 5 16 59 62 63 64 60 61 67 68 69 70 71 72 73 74 75...
Page 27 - Parts List
24 100153 ENGLISH Parts List # Part Number Description qty 1 2.06.006 Clamp (Ø7× Ø1) 3 2 2.05.001 Clamp (Ø8 ×6.5) 2 3 152.070014.05 Pipe, Reversal Valve (810 mm) 1 4 152.070013.03 Pipe, Air Cleaner (135 mm) 1 5 1.5789.0608 Flange Bolt M6× 8 6 6 152.070018.02 Board, Heat Insulation 1 7 152.070702.06 ...
Page 28 - Engine Parts Diagram
25 ENGLISH 100153 SPECIFICATIONS Engine Parts Diagram 45 64 40 10 2 10 3 10 4 10 5 91 10 6 10 7 11 0 10 9 10 8 85 10 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 17 18 19 20 16 24 25 26 27 28 29 30 31 33 34 35 12 36 30 37 38 23 39 41 42 43 44 46 47 48 49 50 51 52 53 12 54 55 57 58 59 60 61 62 65 66 68 69 70 ...
Page 30 - TROUBLESHOOTING; For further technical support :
27 ENGLISH 100153 TROUBLESHOOTING For further technical support : Technical ServiceMon – Fri 8:30 AM – 5:00 PM (PST/PDT)Toll Free: 1-877-338-0999tech@ championpowerequipment.com Problem Cause Solution Generator will not start No fuel Add fuel Faulty spark plug Replace spark plug Unit loaded during s...
Page 31 - WARRANTy; Installation, Use and Maintenance Cont’d.
28 100153 ENGLISH WARRANTy WARRANT y CHAMPION POWER EQUIPMENT 2 YEAR LIMITED WARRANTY Warranty Qualifications Champion Power Equipment (CPE) will register this warranty upon receipt of your Warranty Registration Card and a copy of your sales receipt from one of CPE’s retail locations as proof of pur...