Page 2 - Have questions or need assistance?; Call our Customer Care Team Toll-Free at:; AN IMPORTANT MESSAGE ABOUT TEMPERATURE:
*We are always working to improve our products. Therefore, the enclosed product may differ slightly from the image on the cover. Have questions or need assistance? Do not return this product to the store ! WE ARE HERE TO HELP! Visit our website: www.championpowerequipment.com for more info: • Produc...
Page 3 - TABLE Of CONTENTS; Recoil Start; PORTABLE GENERATOR
100106 TABLE Of CONTENTS Introduction 1 Introduction 1 Portable Power Generator 1 Accessories 1 This Booklet 1 Manual Conventions 2 Safety Rules 3 Controls and Features 5 Generator 5 Power Panel 6 Parts Included 7 Wheel Kit 7 Other 7 Assembly 8 Remove the Generator from the Shipping Carton 8Install ...
Page 4 - ENGLISH; Introduction; Model Number; INTRODUCTION
1 REV 100106-20140822 ENGLISH 100106 Introduction Congratulations on your purchase of a Champion Power Equipment generator. CPE designs and builds generators to strict specifications. With proper use and maintenance, this generator will bring years of satisfying service. Portable Power Generator Thi...
Page 5 - MANUAL CONVENTIONS; CAUTION; DANGER; WARNING
REV 100106-20140822 2 100106 ENGLISH This manual uses the following symbols to help differentiate between different kinds of information. The safety symbol is used with a key word to alert you to potential hazards in operating and owning power equipment.Follow all safety messages to avoid or reduce ...
Page 6 - SAfETy RULES; When servicing the generator:
3 REV 100106-20140822 ENGLISH 100106 SAfETy RULES Generator exhaust contains carbon monoxide, a colorless, odorless, poison gas. Breathing carbon monoxide will cause nausea, dizziness, fainting or death. If you start to feel dizzy or weak, get to fresh air immediately. Operate generator outdoors onl...
Page 7 - When adding or removing fuel :
REV 100106-20140822 4 100106 ENGLISH SAfETy RULES Improper treatment or use of the generator can damage it, shorten its life and void your warranty. Use the generator only for intended uses.Operate only on level surfaces.DO NOT expose generator to excessive moisture, dust, or dirt.DO NOT allow any m...
Page 8 - Generator; CONTROLS AND fEATURES
5 REV 100106-20140822 ENGLISH 100106 Read this owner’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference. (1) Fuel Tank – 6.1 gallon (23 L) capacity fuel tank. (2) Choke Lever – Used to star...
Page 9 - Power Panel
REV 100106-20140822 6 100106 ENGLISH Power Panel CONTROLS AND fEATURES (1) Voltmeter – Displays the output voltage of the generator. (2) Circuit Breaker(s) – Protects the generator against electrical overload. (3) Engine Switch – Flip the switch to the “On” position and pull the recoil starter to st...
Page 10 - Parts Included; Wheel Kit
7 REV 100106-20140822 ENGLISH 100106 Parts Included Your 100106 gasoline powered generator ships with the following parts: Wheel Kit – 8 in. Wheel 2 – Bushing 2 – Flange Bolt (M10x105 for Wheel) 2 – Flat Washer Ø10 2 – Lock Nut (M10) 2 – Support Leg w/ Vibration Mounts 1 – Flange Bolt (M8x16 for Sup...
Page 11 - Remove the Generator from the Shipping Carton; ASSEMBLy; Install the Handle
REV 100106-20140822 8 100106 ENGLISH Your generator requires some assembly. This unit ships from our factory without oil. It must be properly serviced with fuel and oil before operation.If you have any questions regarding the assembly of your generator, call our help line at 1-877-338-0999. Please h...
Page 12 - Add Engine Oil; Add Engine Oil Cont’d.
9 REV 100106-20140822 ENGLISH 100106 ASSEMBLy Add Engine Oil Add Engine Oil Cont’d. 1. Place the generator on a flat, level surface. 2. Remove oil fill cap /dipstick to add oil.3. Add up to 1.2 qt. (1.1 L) of oil and replace oil fill cap/dipstick. DO NOT OVERFILL. 4. Check engine oil level daily and...
Page 13 - Grounding; Add fuel
REV 100106-20140822 10 100106 ENGLISH ASSEMBLy Grounding Your generator must be properly connected to an appropriate ground to help prevent electric shock. A ground terminal connected to the frame of the generator has been provided on the power panel. For remote grounding, connect of a length of hea...
Page 14 - Generator Location; OPERATION; Surge Protection
11 REV 100106-20140822 ENGLISH 100106 Generator Location NEVER operate the generator inside any building, including garages, basements, crawlspaces and sheds, enclosure or compartment, including the generator compartment of a recreational vehicle. Please consult your local authority. In some areas, ...
Page 15 - Connecting Electrical Loads; Stopping the Engine; NOTE; Starting the Engine; NOTE
REV 100106-20140822 12 100106 ENGLISH Connecting Electrical Loads 1. Let the engine stabilize and warm up for a few minutes after starting 2. Plug in and turn on the desired 120/240 Volt AC single phase, 60 Hz electrical loads. – DO NOT connect 3-phase loads to the generator. – DO NOT connect 50 Hz ...
Page 16 - Do Not Overload Generator; Capacity; Power Management
13 REV 100106-20140822 ENGLISH 100106 Do Not Overload Generator Capacity Follow these simple steps to calculate the running and starting watts necessary for your purposes. 1. Select the electrical devices you plan on running at the same time. 2. Total the running watts of these items. This is the am...
Page 17 - Air filter; Engine Maintenance; Oil; MAINTENANCE AND STORAGE
REV 100106-20140822 14 100106 ENGLISH Air filter 1. Remove the snap-on cover holding the air filter to the assembly. 2. Remove the foam element. 3. Wash in liquid detergent and water. Squeeze thoroughly dry in a clean cloth. 4. Saturate in clean engine oil. 5. Squeeze in a clean, absorbent cloth to ...
Page 18 - Maintenance Schedule; Cleaning; Spark Arrester
15 REV 100106-20140822 ENGLISH 100106 Maintenance Schedule Follow the service intervals indicated in the following maintenance schedule. Service your generator more frequently when operating in adverse conditions. Contact our help line at 1-877-338-0999 to locate the nearest Champion Power Equipment...
Page 19 - Generator Maintenance; Storage; Generator Storage; Generator Storage Cont’d.
REV 100106-20140822 16 100106 ENGLISH MAINTENANCE AND STORAGE Generator Maintenance Make certain that the generator is kept clean and stored properly. Only operate the unit on a flat, level surface in a clean, dry operating environment. DO NOT expose the unit to extreme conditions, excessive dust, d...
Page 20 - SPECIfICATIONS
17 REV 100106-20140822 ENGLISH 100106 Oil Use 10W-30 automotive oil.Oil capacity is up to 1.2 qt (1.1 L).DO NOT OVERFILL.Please reference the following chart for recommended oil types for use in the generator. fuel Fuel capacity is 6.1 gallons (23 L). Use regular unleaded gasoline with a minimum oct...
Page 21 - Wiring Diagram; AVR
REV 100106-20140822 18 100106 ENGLISH Wiring Diagram SPECIfICATIONS AVR L W G B Y R YELL OW BLA CK BLU E GRE EN RE D WHI TE B r WHITE B LU E GREEN YEL LO W WHITE GR EE N BRO WN BLACK WH IT E B/ W W/ L G/ Y W/ G W R G/ Y Y W L L R W + MW 1 F W EX W I n INDI GO ENGINE BL OC K GENERATOR BLOC K EART H T...
Page 22 - Parts Diagram
19 REV 100106-20140822 ENGLISH 100106 Parts Diagram SPECIfICATIONS 16 17 18 19 20 21 22 23 24 26 28 29 30 31 32 33 34 30 35 36 37 29 30 38 39 40 41 42 43 44 45 46 47 48 49 51 52 53 54 40 1 3 5 6 7 8 9 10 11 12 13 14 15 10 93 94 95 4 50 2 58 59 60 65 70 71 72 17 74 75 76 71 79 80 81 82 84 85 86 87 88...
Page 23 - Parts List
REV 100106-20140822 20 100106 ENGLISH Parts List # Part Number Description Qty 1 2.06.006 Clamp (Ø7ר1) 1 2 24.070030.00 Hole, Breather Tube 1 3 2.05.001 Clamp (Ø8×6.5) 2 4 152.070014.06 Pipe, Reversal Valve (730 mm) 1 5 122.070100.07 Fuel Tank Cap 1 6 122.070300.03 Fuel Filter 1 7 24.070800.00 Reve...
Page 24 - Engine Parts Diagram
21 REV 100106-20140822 ENGLISH 100106 Engine Parts Diagram SPECIfICATIONS 4 3 6 2 3 8 9 5 9 6 9 7 9 8 8 9 9 9 10 0 10 3 10 2 10 1 8 3 1 0 1 2 3 4 5 6 7 8 9 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 3 1 3 2 3 3 1 2 3 4 2 8 3 5 3 6 2 1 3 7 3 9 4 0 4 1 4 2 4 4 4 5 4 6 4 7 ...
Page 26 - TROUBLESHOOTING; for further technical support :
23 REV 100106-20140822 ENGLISH 100106 Problem Cause Solution Generator will not start No fuel Add fuel Faulty spark plug Replace spark plug Unit loaded during start up Remove load from unit Generator will not start;Generator starts but runs roughly Low oil level Fill crankcase to the proper levelPla...
Page 27 - Installation, Use and Maintenance Cont’d.; WARRANTy
REV 100106-20140822 24 100106 ENGLISH WARRANT y CHAMPION POWER EQUIPMENT 2 YEAR LIMITED WARRANTY Warranty Qualifications Champion Power Equipment (CPE) will register this warranty upon receipt of your Warranty Registration Card and a copy of your sales receipt from one of CPE’s retail locations as p...