2 00831.0000 00657.0000 USER NOTICES The notices on this dispenser should be kept in good condition. Replace unreadable or damaged labels. 10052 060700
3 ELECTRICAL REQUIREMENTS CAUTION - The dispenser must be unplugged until specified in Initial Set-Up. The Model HW2 has an attached cordset and requires 2-wire, grounded service rated 120V ac, 15 amp, single phase, 60 Hz. The Model Hw2A requires 2-wire grounded service rated 240V ac, 8 amp, single ...
4 1700W TANK HEATER 1 4 LIMIT THERMOSTAT BLK 10261.0000E 5/98 © 1987 BUNN-O-MATIC CORPORATION SCHEMATIC WIRING DIAGRAM HW2 L1 N BLK BLK WHI SOL GREEN 3 2 BLU/BLK WHI WHI BLK BLK LIQUID LEVEL BOARD SAFETY SW (PROBE) P NK WHI WHI WHI WHI KEEP WARM HEATER 40W SW. & THERMOSTAT KEEP WARM HEATER 40W 1...