Page 2 - FEATURES AND BENEFITS
2 SAP ORDERING NO. CASING DIMENSIONS (IN.) RATED HEATING OUTPUT† HEATING AIRFLOW COOLING CFM @ 0.5 ESP (in WC) MOTOR HP-SPEED APPROX SHIP WEIGHT (LB) H D W (BTUH) AFUE CFM‡ Heating ESP (in. WC) 915SA30040S14 35 29.5 14.2 39,000 95.5% 820 0.10 625-905 1/2 - 4 123 915SA30060S14 35 29.5 14.2 58,000 95....
Page 3 - SPECIFICATIONS; Heating Capacity and Efficiency; Airflow Capacity and Blower Data
3 SPECIFICATIONS Heating Capacity and Efficiency 30040 30060 42060 48080 60080 42100 60100 60120 60140 Input HighHeat (BTUH) 40,000 60,000 60,000 80,000 80,000 100,000 100,000 120,000 140,000 Output HighHeat (BTUH) 39,000 58,000 58,000 78,000 78,000 97,000 97,000 117,000 135,000 Efficiency AFUE % (I...
Page 4 - MODEL NUMBER NOMENCLATURE; FURNACE COMPONENTS
4 MODEL NUMBER NOMENCLATURE 91 5 S A 30 040 S 14 A -- A S - Single StageT - Two StageM - Modulating 0 --- 90 AFUE3 --- 93 AFUE5 --- 95 AFUE6 --- 96 AFUE7 --- 97 AFUE S - StandardE - Energy EfficientV - Variable Speed 14 - 14.2”17 - 17.5”21 - 21.0”24 - 24.5” 91 - Legacy92 - Preferred98 - Evolution Vo...
Page 5 - ACCESSORIES
5 ACCESSORIES Part Number Used With Notes KGADC0101BVC All 1 KGAVT0701CVT See Venting Tables 1 KGAVT0801CVT See Venting Tables 1 KGAVT0101BRA See Venting Tables 1, 2 KGAVT0201BRA See Venting Tables 1, 2 Part Number Used With Notes KGAHT0201CFP All 7 KGAHT0101CFP All - KGAAD0110PVC All - KGACK0101HCK...
Page 8 - Venting System Length Calculations; FOR EACH; long radius elbows and a concentric vent kit.; EACH
8 MAXIMUM EQUIVALENT VENT LENGTH -- FT. (M) Table 2 – Deductions from Maximum Equivalent Vent Length -- Ft. (M) Pipe Diameter (in): 1-1/2 2 2-1/2 3 4 Mitered 90º Elbow 8 (2.4) 8 (2.4) 8 (2.4) 8 (2.4) 8 (2.4) Medium Radius 90º Elbow 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) Long Radius 90º Elbow 3 (0.9...
Page 11 - RETURN AIR TEMPERATURE; C) db or intermittent operation down to 55; SUPPLY AIR; MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS; ELBOW
11 RETURN AIR TEMPERATURE This furnace is designed for continuous return--air minimum temperature of 60 _ F (15 _ C) db or intermittent operation down to 55 _ F (13 _ C) db such as when used with a night setback thermometer. Return--air temperature must not exceed 80 _ F (27 _ C) db. Failure to foll...
Page 12 - DOWNFLOW SUBBASE; Assembled; FURNACE; Concentric Vent Kit; installed in downflow applications.
12 DOWNFLOW SUBBASE LOCATING TAB LOCATING TAB 1 2 3 4 4 3 2 1 B D C A 1 1 / 4-IN. TYP PLENUMOPENING FACTORY-SUPPLIED FIELD-INSTALLED INSULATION Assembled Disassembled A97427 A88207 DIMENSIONS (IN. / MM) FURNACE CASING WIDTH FURNACE IN DOWNFLOW APPLICATION PLENUM OPENING* FLOOR OPENING HOLE NO. FOR W...
Page 13 - MEDIA FILTER CABINET; B Opening; TYPICAL WIRING SCHEMATIC
13 MEDIA FILTER CABINET Media Filter Cabinet A B 16" (406mm) 20" (508mm)24" (610mm) 17" (432mm) Furnace Side Centerline Screw Slots 23-3/4” 23-3/8” 23-5/8" 5 3 4 Duct Side Opening Opening with Flanges Bent 24-1/4” 25-5/8" B Opening A " (600mm) (594mm) (603mm) (146mm) (651...
Page 14 - DIMENSIONAL DRAWING
Page 15 - GUIDE SPECIFICATIONS; General
15 GUIDE SPECIFICATIONS General System Description Furnish a ______________________ 4--way multipoise gas--fired condensing furnace for use with natural gas or propane (factory--authorized conversion kit required for propane); furnish cold air return plenum; furnish external media cabinet for use wi...