Page 2 - IMPORTANT
2 www.bromicheating.com Head Office: 10 Phiney Place, Ingleburn, Sydney, NSW 2565 Australia T: 1300 276 642 (within Australia) or +61 2 9748 3900 (from overseas) F: +61 2 9748 4289 E: [email protected] W: www.bromic.com.au ! IMPORTANT This manual contains important information about the assembly, op...
Page 3 - CONTENTS
3 www.bromicheating.com CONTENTS IMPORTANT NOTES & WARNINGS 4 PRODUCT OVERVIEW 5 PRODUCT DESCRIPTION 5 SPECIFICATIONS 5 GENERAL INFORMATION 6 PRODUCT FEATURES 6 INSTALLATION REQUIREMENTS 6 GAS REQUIREMENTS 6 INSTALLATION CLEARANCES 7 INSTALLATION INSTRUCTIONS 8 HEATER INSTALLATION INSTRUCTIONS 8...
Page 4 - IMPORTANT NOTES AND WARNINGS; WARNING
4 www.bromicheating.com IMPORTANT NOTES AND WARNINGS WARNING • THIS APPLIANCE SHALL NOT BE INSTALLED OR USEDIN RESIDENTIAL DOMESTIC INDOOR AREAS • DO NOT PLACE ARTICLES ON OR AGAINST THISAPPLIANCE • DO NOT USE OR STORE FLAMMABLE MATERIALSNEAR THIS APPLIANCE • DO NOT SPRAY AEROSOLS OR FLAMMABLE MATER...
Page 5 - PRODUCT OVERVIEW; PRODUCT DESCRIPTION; PLATINUM Smart-Heat 300; PLATINUM SMART-HEAT HEATER DIMENSIONAL DETAILS
5 www.bromicheating.com PRODUCT OVERVIEW PRODUCT DESCRIPTION The Platinum Smart-Heat Gas Radiant Heaters are designed to provide effective outdoor heating to both commercial and residential premises whilst offering a unique and appealing design. Radiant gas burners provide heat which is passed throu...
Page 6 - GENERAL INFORMATION; INSTALLATION REQUIREMENTS
6 www.bromicheating.com PRODUCT OVERVIEW CONTINUED... GENERAL INFORMATION The Platinum Smart-Heat Gas radiant heaters are suitable for outdoor and non-residential indoor spaces. In addition to the installation instructions provided, authorised installers must abide by the Australian installation cod...
Page 7 - INSTALLATION CLEARANCES
7 www.bromicheating.com INSTALLATION CLEARANCES When selecting the installation location for the Platinum Smart-Heat Heaters, the following mounting clearances should be followed. Care should be taken to ensure that the heater is not installed:• Where heat/ignition can cause damage to gas cylinders/...
Page 8 - INSTALLATION INSTRUCTIONS; HEATER INSTALLATION INSTRUCTIONS
8 www.bromicheating.com INSTALLATION INSTRUCTIONS HEATER INSTALLATION INSTRUCTIONS CAUTION Please see specifications for the weight of the Heater. The installer of the Platinum Smart-Heat Series Radiant Heaters must comply with all relevant State Occupational Health & Safety Regulations. ! 1. Mo...
Page 14 - OPERATING INSTRUCTIONS; MAINTENANCE AND SERVICING
14 www.bromicheating.com OPERATING INSTRUCTIONS TURNING THE APPLIANCE ON 1. Ensure that gas installation and power installation has been carried out in accordance with the manufacturers instructions outlined in this document. 2. Turn on gas supply. 3. Ensure correct gas supply pressures are set. 4. ...
Page 15 - OPERATION DATA - HONEYWELL CONTROL BOX; OPTIMUM MOUNTING DISTANCE
15 www.bromicheating.com IMPORTANT Do not apply any additional surface coating to the heater under any circumstances. Use of additional coating other than those applied during manufacture could result in hazardous reactions such as toxic fumes or fires. Additional coatings will void the warranty. ! ...
Page 17 - OPERATION DATA - BRAHMA CONTROL BOX
17 www.bromicheating.com OPERATION DATA - BRAHMA CONTROL BOX The following operation sequence is valid only where the components are installed according to the manufactures assembly and installation instructions. Please do not modify the wiring configuration, gas train or any other part of the heate...
Page 19 - WIRING DIAGRAM - HONEYWELL CONTROL, HONEYWELL GAS VALVE; HONEY WELL; ELECTRICAL DIAGRAM; SEE INSTRUCTION MANUAL FOR DETAILS ON HOW
19 www.bromicheating.com WIRING DIAGRAM - HONEYWELL CONTROL, HONEYWELL GAS VALVE 12 11 10 9 8 7 6 5 4 3 2 1 N L E Blue Brown 230 V N/A Yellow/Green Y ello w/G reen Y ello w/G reen Green White Black Ignition + Ionisation HONEY WELL Red 230 V Blue P ur ple P ur ple ELECTRICAL DIAGRAM SEE INSTRUCTION M...
Page 20 - WIRING DIAGRAM
20 www.bromicheating.com WIRING DIAGRAM F2a L N E + Orange Brown Blue Y ello w/G reen Y ello w/G reen Yellow/Green Black White Blue Purple Brahma Control Box CE11U Gas Valve Ignition + Ionisation C 1 ELECTRICAL DIAGRAM SEE INSTRUCTION MANUAL FOR DETAILS ON HOW TO CONNECT THE ELECTRICAL COMPONENTS.
Page 21 - REPLACEMENT PARTS
21 www.bromicheating.com REPLACEMENT PARTS 8 13 16 7 1 2 1 4 5 6 9 10 15 30 14 29 12 18 24 28 19 23 17 22 27 26 21 17 20 25 White Rodger Honeywell
Page 23 - POST-INSTALLATION REPORT; FOR PLATINUM GAS RADIANT HEATERS
23 www.bromicheating.com POST-INSTALLATION REPORT Customer Business Name: Date: dd / mm / yyyy Site Address: Suburb: State: Postcode: Customer Contact Details: Name: Position: Ph: ( ) Fax: ( ) Mobile: Installer Contact Details: Name: Position: Ph: ( ) Fax: ( ) Mobile: POST-INSTALLATION REPORT FOR PL...
Page 24 - TROUBLESHOOTING; SYMPTOM
24 www.bromicheating.com TROUBLESHOOTING SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION Heater will not turn on 1. No power2. No gas 1. Have authorised electrician check power supply 2. Have authorised gas fitter check gas supply Heater turns on, but then cycles on and off 1. Insufficient flame on ionisat...
Page 25 - APPENDIX A