Page 2 - Pre-Installation Information; Barrier-free and ADA compliant - standard height mounting
2 Express® Lavatory System SS-SeriesSS-2/AST/STD, SS-2/AST/JUV Installation Instructions - For Service Only 5/11/04 Bradley Corporation • 215-1244 Rev. C; EN 03-813 Pre-Installation Information Barrier-free and ADA compliant - standard height mounting The SS-2/AST/STD Express® Lavatory System is com...
Page 3 - Dimensions
3 Express® Lavatory System SS-Series Installation Instructions - For Service Only SS-2/AST/STD, SS-2/AST/JUV Bradley Corporation • 215-1244 Rev. C; EN 03-813 5/11/04 8" (203) 22" (559) 34" (864) 6" (152) 50" (1270) 8" (203) Radius 30" (762) 8.5" (216) 21" (533) 10...
Page 4 - Standard Height
4 Express® Lavatory System SS-SeriesSS-2/AST/STD, SS-2/AST/JUV Installation Instructions - For Service Only 5/11/04 Bradley Corporation • 215-1244 Rev. C; EN 03-813 Dimensions continued . . . 38" (965) 34" (864) 29" (737) 11" (279) 9" (229) 6" (152) 4" (102) 30" (762)...
Page 5 - lines can cause the valves to malfunction.; installer) at the locations shown in Figures 1a and 1b.; Installation Instructions
5 Express® Lavatory System SS-Series Installation Instructions - For Service Only SS-2/AST/STD, SS-2/AST/JUV Bradley Corporation • 215-1244 Rev. C; EN 03-813 5/11/04 Installation Instructions Step 1: Rough in Note: See Figure 1a below (for Standard Height) and Figure 1b on page 6 (for Juvenile Heigh...
Page 6 - Juvenile Height Mounting
6 Express® Lavatory System SS-SeriesSS-2/AST/STD, SS-2/AST/JUV Installation Instructions - For Service Only 5/11/04 Bradley Corporation • 215-1244 Rev. C; EN 03-813 Installation Instructions continue . . . Figure 1b (MM) 28" (711) 24-5/8" (625) 21" (533) 11-3/8" (289) (6) 3/8" WA...
Page 7 - Step 2: Mounting frame to wall; behind the frame to ensure that it will not bend when anchored.
7 Express® Lavatory System SS-Series Installation Instructions - For Service Only SS-2/AST/STD, SS-2/AST/JUV Bradley Corporation • 215-1244 Rev. C; EN 03-813 5/11/04 Installation Instructions continue . . . Installation Instructions continued . . . Step 2: Mounting frame to wall 1. Remove the eight ...
Page 8 - Step 3: Installing bowl assembly; Note: Refer to Figure 5 below when installing the bowl assembly.; en bolts. Overtightening bolts can damage the Terreon® material.; by the installer) to bolt the bowl to the wall anchors.
8 Express® Lavatory System SS-SeriesSS-2/AST/STD, SS-2/AST/JUV Installation Instructions - For Service Only 5/11/04 Bradley Corporation • 215-1244 Rev. C; EN 03-813 Installation Instructions continued . . . Step 3: Installing bowl assembly IMPORTANT: Moving and positioning the bowl will require more...
Page 9 - Step 4: Connecting supply and drain; drain pipe stubbed out of the wall.
9 Express® Lavatory System SS-Series Installation Instructions - For Service Only SS-2/AST/STD, SS-2/AST/JUV Bradley Corporation • 215-1244 Rev. C; EN 03-813 5/11/04 Installation Instructions continued . . . Step 4: Connecting supply and drain 1. FOR HOT AND COLD SUPPLY: Connect the flexible hoses i...
Page 10 - Step 5: Connecting plastic tubing
10 Express® Lavatory System SS-SeriesSS-2/AST/STD, SS-2/AST/JUV Installation Instructions - For Service Only 5/11/04 Bradley Corporation • 215-1244 Rev. C; EN 03-813 Installation Instructions continued . . . Step 5: Connecting plastic tubing NOTE: Refer to Figure 8a for hot and cold supplies, and re...
Page 11 - Step 5: Completing installation; Turn on the water supply to the Express® and check for leaks.
11 Express® Lavatory System SS-Series Installation Instructions - For Service Only SS-2/AST/STD, SS-2/AST/JUV Bradley Corporation • 215-1244 Rev. C; EN 03-813 5/11/04 Installation Instructions continued . . . Step 5: Completing installation 1. Turn on the water supply to the Express® and check for l...
Page 12 - Cleaning and Maintenance Instructions; Terreon® and panel maintenance; Wipe the surface with a damp cloth and wipe dry.; Panel cleaning; If vandals create markings on the panel, Bradley recommends using
12 Express® Lavatory System SS-SeriesSS-2/AST/STD, SS-2/AST/JUV Installation Instructions - For Service Only 5/11/04 Bradley Corporation • 215-1244 Rev. C; EN 03-813 Cleaning and Maintenance Instructions IMPORTANT: Strong alkaline or acid-based chemicals and cleansers should not beused to clean Terr...
Page 13 - Soap Dispenser Maintenance; Step 1: Fill soap dispensers
13 Express® Lavatory System SS-Series Installation Instructions - For Service Only SS-2/AST/STD, SS-2/AST/JUV Bradley Corporation • 215-1244 Rev. C; EN 03-813 5/11/04 Soap Dispenser Maintenance Step 1: Fill soap dispensers The two soap valves will dispense vegetable/coconut oil liquid soaps, synthet...
Page 14 - Step 2: Change soap type; cleaners can mar the surface.; Check Valve Troubleshooting; If water just dribbles or does not flow from sprayhead:
14 Express® Lavatory System SS-SeriesSS-2/AST/STD, SS-2/AST/JUV Installation Instructions - For Service Only 5/11/04 Bradley Corporation • 215-1244 Rev. C; EN 03-813 Soap Dispenser Maintenance continued . . . Step 2: Change soap type 1. Pour out all of the soap from the dispenser. 2. Rinse the soap ...
Page 15 - Assembly of Components; Paneling; VernathermTM Thermostatic Mixing Valve
15 Express® Lavatory System SS-Series Installation Instructions - For Service Only SS-2/AST/STD, SS-2/AST/JUV Bradley Corporation • 215-1244 Rev. C; EN 03-813 5/11/04 SPRAYHEAD COVER/SHELF (part number varies with color ofunit—contact your local Bradleyrepresentative for assistance) ACCESS PANEL Sta...
Page 16 - Other Replacement Parts; Pushbutton assembly
16 Express® Lavatory System SS-SeriesSS-2/AST/STD, SS-2/AST/JUV Installation Instructions - For Service Only 5/11/04 Bradley Corporation • 215-1244 Rev. C; EN 03-813 Other Replacement Parts Assembly of Components continued . . . Pushbutton assembly U-CUP 125-099 PISTON 119-227 NUT 110-115 STREAMFORM...
Page 17 - Metering Air Valve Maintenance; Metering Air Valve Repair Kits and Parts List; Problem: Water is dripping from the streamformers; Solution: Clean and inspect the valve seat.; Metering Air Valve Troubleshooting
17 Express® Lavatory System SS-Series Installation Instructions - For Service Only SS-2/AST/STD, SS-2/AST/JUV Bradley Corporation • 215-1244 Rev. C; EN 03-813 5/11/04 PLASTIC DISK269-664 Metering Air Valve Maintenance Metering Air Valve Repair Kits and Parts List Metering Air Valve Troubleshooting P...
Page 18 - Turn the adjusting screw in all the way but do not force screw.; Problem: Timing can not be adjusted for more than 5 seconds.; Check all tubing and fittings for proper assembly.; Problem: Pushbutton does not work properly.; Cause: Air volume may not be sufficient to operate valve.
18 Express® Lavatory System SS-SeriesSS-2/AST/STD, SS-2/AST/JUV Installation Instructions - For Service Only 5/11/04 Bradley Corporation • 215-1244 Rev. C; EN 03-813 Metering Air Valve Troubleshooting Problem: Valve will not shut off. Cause: Timing mechanism is clogged. Solution: Clean timing mechan...
Page 19 - THEN; VernathermTM Mixing Valve Maintenance and Service; Maintenance Instructions; Disassemble the VernathermTM Valve as shown,; Service Suggestions; NOTE: A red marking indicates the hot side of the valve.; IF
19 Express® Lavatory System SS-Series Installation Instructions - For Service Only SS-2/AST/STD, SS-2/AST/JUV Bradley Corporation • 215-1244 Rev. C; EN 03-813 5/11/04 THEN Valve Position is Hot Supply Cold Supply Valve Delivers Correct Hot Cold Mixed 107° Correct Hot No Water Valve shuts off or drip...