Bradley CRS-3/IR - Manual

Bradley CRS-3/IR

Bradley CRS-3/IR – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
Page: / 14

Table of Contents:

  • Page 2 – Express® Crescent® Lavatory System Dimensions
  • Page 3 – Installation Instructions; Supplies required for installation:; NOTE: Refer to Figure 1 below and Figure 2 on page 4 for Express; supply lines will cause the valves to malfunction.; Figure 1; Standard Height Mounting
  • Page 4 – at the locations marked in Figure 2.; Figure 2
  • Page 5 – Step 3: Install wall anchors; Figure 3
  • Page 6 – Step 6: Install drain spud; Step 7: Connecting Supply; Connect one end of the supply hoses to the; IMPORTANT: The hose attached to the hot; Express; Figure 4; DRAIN ASSEMBLY; Figure 5
  • Page 7 – Electrical and supply connections; Figure 6a
  • Page 8 – Electrical and supply connections, cont’d.; counterclockwise; Figure 6b
  • Page 9 – Step 9: Install the Optional Soap Dispenser; Carefully place the top cover on top of the lavatory system bowl.
  • Page 10 – Cleaning and Maintenance Instructions; Terreon® and trap cover maintenance; cleaners can mar the surface.; remove soil and maintain the glossy finish.; Bowl and cover cleaning; Wipe the unit with a damp cloth and then wipe dry.
  • Page 11 – Solenoid Valve Troubleshooting; CAUTION: Turn off water supplies to unit before troubleshooting.; careful not to lose the armature or spring (see Figure 8 on page 12).; An individual operating station fails to turn on.; valve and reconnect to the adjacent valve.
  • Page 12 – Figure 8
  • Page 13 – Thermostatic Mixing Valve Troubleshooting; connections or leaking stop/check valves.; Problem: Limited water flow; Cause: Dirt and debris have built up in the valve or strainer.; Problem: External leaks in the system; Cause: Thermostat is slowly failing or not working at all.; increase; the temperature or; clockwise; to; decrease
  • Page 14 – Figure 9
Loading the manual

CRS-2/IR, CRS-3/IR

Express® Crescent®
Lavatory System
CRS-Series

Complies with Texas
Accessibility Standards (TAS)
for Juvenile Height applications.

Installation
Instructions

P.O. Box 309, Menomonee Falls, WI 53052-0309
TEL. 1-800-BRADLEY

FAX 262-251-5817

http://www.bradleycorp.com

Table of Contents

Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Installation Instructions . . . . . . . . . . . . . . . . . . . . . 3–9
Cleaning and Maintenance . . . . . . . . . . . . . . . . . . . .10
Solenoid Valve Troubleshooting . . . . . . . . . . . . . . .11
Solenoid Valve Repair Parts . . . . . . . . . . . . . . . . . .12
Vernatherm™ Valve Troubleshooting . . . . . . . . . . .13
Vernatherm™ Valve Repair Parts . . . . . . . . . . . . . .14
Cleaning the Strainer . . . . . . . . . . . . . . . . . . . . .13-14

For soap system installation, refer to installation manual
215-1583

NOTE: 3-station unit is shown throughout. 2-station
is similar.

A

D

A

C

O

M

P LIA NT

IMPORTANT

Read this entire installation manual to ensure proper installation, then
file these instructions with the owner or maintenance department.

Flush all the water supply lines before making connections. Debris in
supply lines will cause the valves to malfunction.

Wall anchors used must have a minimum pull-out rating of 1,000 lbs.

Product warranties may be found under "Product Information" on our
web site at www.bradleycorp.com.

215-1330 Rev. K; EN 06-915
© 2007 Bradley Corporation
Page 1 of 14

2/8/07

TAS

CRS-3/IR/LSD

CRS-2/IR/LSD

U

P

C

R

C

NAHB

NAHB

R E S E A R C H

R E S E A R C H

C E N T E R

C E N T E R

C

E

RT

IFI

ED PROD

U

C

T

3

0

1

-2

4

9

-4

00

0 www.na

hb

rc

.o

rg

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Express® Crescent® Lavatory System Dimensions

Express ® Crescent ® Lavatory System - CRS-Series CRS-2/IR, CRS-3/IR Installation Instructions 2 2/8/07 Bradley Corporation • 215-1330 Rev. K; EN 06-915 Express® Crescent® Lavatory System Dimensions 48" (1219) 26" (660) *34" (864) *20" (508) *37-3/8" (949) 8-1/2" (216) (mm) (...

Page 3 - Installation Instructions; Supplies required for installation:; NOTE: Refer to Figure 1 below and Figure 2 on page 4 for Express; supply lines will cause the valves to malfunction.; Figure 1; Standard Height Mounting

Express ® Crescent ® Lavatory System - CRS-Series Installation Instructions CRS-2/IR, CRS-3/IR 3 Bradley Corporation • 215-1330 Rev. K; EN 06-915 2/8/07 Installation Instructions Supplies required for installation: • (6) 3/8" wall anchors, bolts and washers to mount bowl to wall (min. pull-out f...

Page 4 - at the locations marked in Figure 2.; Figure 2

Express ® Crescent ® Lavatory System - CRS-Series CRS-2/IR, CRS-3/IR Installation Instructions 4 2/8/07 Bradley Corporation • 215-1330 Rev. K; EN 06-915 * ADJUSTMENTS TO VERTICAL DIMENSIONS FOR VARIOUS RIM HEIGHTS Rim Height Application Adjustment 34" Adult Height ADA, TAS Adult Height TAS Adult...

Other Bradley Models

All Bradley Other