Page 2 - Installation; Bradley
Aerada 1000/1100 Series Installation 2 5/21/08 Bradley Corporation • 215-1628 Rev. A; EN 08-201 EXPLANATION OF SYMBOLS Symbol Meaning WARNING Refers to a situation of potential danger that may cause serious injury or death. CAUTION Refers to a situation of potential danger that may cause slight or m...
Page 3 - Bradley Corporation
Installation Aerada 1000/1100 Series Bradley Corporation • 215-1628 Rev. A; EN 08-201 5/21/08 3 COMPONENT PARTSAerada 1100 Series High Arc Components & Bradley Part Nos. 1. Spout with External Mixer opening [269-1960] 2. Shut Off Screw Assembly [269-1944] 3. Outlet Assembly Kit Lavatory Spout (....
Page 4 - INSTALLATION; Mounting of Lavatory and Gooseneck Faucet; Prerequisites
Aerada 1000/1100 Series Installation 4 5/21/08 Bradley Corporation • 215-1628 Rev. A; EN 08-201 INSTALLATION This faucet comes with all the components needed for installation,however, some tools and supplies are not included. • Basin Wrench • Adjustable Wrench • Adjustable Locking Pliers • Plumber´s...
Page 5 - Test Function
Installation Aerada 1000/1100 Series Bradley Corporation • 215-1628 Rev. A; EN 08-201 5/21/08 5 Start-up Operation Prerequisites • Faucet is mounted • Water supply is on • Water supply lines are fl ushed properly • For AC faucets, power outlet is installed. 1 Fully open supply valves. 2 Remove all i...
Page 6 - Enabling “Manual Setting Mode”
Aerada 1000/1100 Series Installation 6 5/21/08 Bradley Corporation • 215-1628 Rev. A; EN 08-201 Enabling “Manual Setting Mode” A battery model is shown in the following example. These instructions apply to all models. After 30 minutes, the “Manual Setting” mode will be disabled automatically and all...
Page 7 - A - Setting Cleaning Mode
Installation Aerada 1000/1100 Series Bradley Corporation • 215-1628 Rev. A; EN 08-201 5/21/08 7 9 Mount mixer handle (only for faucets with external mixer) Result: The faucet is now mounted. A - Setting Cleaning Mode Setting the cleaning mode will make the faucet inactive for 90 seconds. 1 Enable “M...
Page 8 - F - Sensor Range Adjustment
Aerada 1000/1100 Series Installation 8 5/21/08 Bradley Corporation • 215-1628 Rev. A; EN 08-201 D - Setting Scrub Mode (60 seconds) Setting scrub mode for 60 seconds will allow the faucet to activate for 60 seconds from the last hand presence. 1 Enable “Manual Setting” Mode > see “Enabling Manual...
Page 9 - FAUCET ADJUSTMENTS; OPERATING MODES
Installation Aerada 1000/1100 Series Bradley Corporation • 215-1628 Rev. A; EN 08-201 5/21/08 9 FAUCET ADJUSTMENTS Operating modes and sensor ranges can be adjusted with a manual operation through the infrared sensor. Faucet adjustment operations apply to all models. OPERATING MODES In order to set ...
Page 10 - Problem; No water fl ow; TROUBLESHOOTING
Aerada 1000/1100 Series Installation 10 5/21/08 Bradley Corporation • 215-1628 Rev. A; EN 08-201 Problem Possible Cause Solution No water fl ow Supply valves are closed Open supply valves Aerator is blocked or dirty Clean or replace aerator (See "Care and Maintenance") Inlet water line fi lt...
Page 11 - Defective electronics module
Installation Aerada 1000/1100 Series Bradley Corporation • 215-1628 Rev. A; EN 08-201 5/21/08 11 Problem Possible Cause Solution Water runs continuously and stops when object present Connector between electronics module and solenoid valve plug is reversed Plug connector properly Water runs continuou...
Page 12 - CARE AND MAINTENANCE INSTRUCTIONS; Activating Cleaning Mode
Aerada 1000/1100 Series Installation 12 5/21/08 Bradley Corporation • 215-1628 Rev. A; EN 08-201 CARE AND MAINTENANCE INSTRUCTIONS The following instructions are described in this section: • Activating Cleaning Mode • Replacing Battery • Cleaning or Replacing Inlet Filter • Adjusting Water Temperatu...
Page 13 - Cleaning or Replacing Inlet Filter
Installation Aerada 1000/1100 Series Bradley Corporation • 215-1628 Rev. A; EN 08-201 5/21/08 13 7 Install shut-off screw. 8 Install mixer handle (for faucets with external mixer only). Result: The battery is now replaced. Cleaning or Replacing Inlet Filter 1 Close supply valves. 2 Disconnected brai...
Page 14 - Cleaning or Replacing Aerator; The aerator is now cleaned or replaced.; Multi-Faucet Transformer Installaion
Aerada 1000/1100 Series Installation 14 5/21/08 Bradley Corporation • 215-1628 Rev. A; EN 08-201 Cleaning or Replacing Aerator 1 Remove shut-off screw. 2 Remove aerator with vandal resistant wrench supplied with the faucet. Clean or replace aerator, then reinstall. 3 Install shut-off screw. Result: ...