Page 2 - Pre-Installation Information; Barrier-free and ADA compliant - standard height mounting
Express® Lavatory System - MG Series with Battery Infrared ControlMG-2/BIR3 Installation Instructions 2 8/23/07 Bradley Corporation • 215-1510 Rev. D; ECN 07-815 Pre-Installation Information Barrier-free and ADA compliant - standard height mounting The MG-2/BIR3 Express® Lavatory System with Battery...
Page 3 - MG-2/BIR3 Express® Lavatory System Dimensions
3 Express® Lavatory System - MG Series with Battery Infrared Control Installation Instructions MG-2/BIR3 Bradley Corporation • 215-1510 Rev. D; ECN 07-815 8/23/07 MG-2/BIR3 Express® Lavatory System Dimensions 27" (686) 47" (1194) 54" (1372) 42" (1067) 15" (381) *Subtract 4" f...
Page 4 - TAS Juvenile Height; Grades Pre-K thru 5 or 6
Express® Lavatory System - MG Series with Battery Infrared ControlMG-2/BIR3 Installation Instructions 4 8/23/07 Bradley Corporation • 215-1510 Rev. D; ECN 07-815 Dimensions continued . . . TAS Juvenile Height Grades 6 thru 8 or 9 TAS Juvenile Height Grades Pre-K thru 5 or 6 35-1/2" (902) 30"...
Page 5 - Step 1: Rough in supplies and optional hot water heater; lines will cause the valves to malfunction.; Figure 1; Standard Height Mounting
5 Express® Lavatory System - MG Series with Battery Infrared Control Installation Instructions MG-2/BIR3 Bradley Corporation • 215-1510 Rev. D; ECN 07-815 8/23/07 Installation Instructions Step 1: Rough in supplies and optional hot water heater NOTE: See Figure 1 (below), 1a, 1b (for TAS on page 6) ...
Page 6 - Figure 1a; Figure 1b
Express® Lavatory System - MG Series with Battery Infrared ControlMG-2/BIR3 Installation Instructions 6 8/23/07 Bradley Corporation • 215-1510 Rev. D; ECN 07-815 Figure 1a TAS - Texas AccessibilityStandards: Juvenile Height (gradesPre-K thru 5 or 6) 4" (102 ) FLOOR APPROX. DIMENSION 14" (356...
Page 7 - Step 2: Rough in wall anchors; Figure 2
7 Express® Lavatory System - MG Series with Battery Infrared Control Installation Instructions MG-2/BIR3 Bradley Corporation • 215-1510 Rev. D; ECN 07-815 8/23/07 Installation Instructions continued . . . Step 2: Rough in wall anchors 1. Install six 3/8" wall anchors with a minimum pull-out rati...
Page 8 - Step 3: Mount frame to wall; Loosen, but do not remove the bottom three access panel screws.; Figure 3
Express® Lavatory System - MG Series with Battery Infrared ControlMG-2/BIR3 Installation Instructions 8 8/23/07 Bradley Corporation • 215-1510 Rev. D; ECN 07-815 Installation Instructions continued . . . Step 3: Mount frame to wall 1. Loosen, but do not remove the bottom three access panel screws. 2...
Page 9 - Step 4: Install bowl assembly; to pinch tubing between bowl and frame.; bolts. Overtightening bolts can damage the Terreon® material.; (supplied by the installer) to bolt the bowl to the wall anchors.; Figure 4
9 Express® Lavatory System - MG Series with Battery Infrared Control Installation Instructions MG-2/BIR3 Bradley Corporation • 215-1510 Rev. D; ECN 07-815 8/23/07 Installation Instructions continued . . . Step 4: Install bowl assembly IMPORTANT: See Figure 4 below when installing the bowl assembly. ...
Page 10 - Step 5: Connecting supply; pipe stubbed out of the wall.; Figure 5c
Express® Lavatory System - MG Series with Battery Infrared ControlMG-2/BIR3 Installation Instructions 10 8/23/07 Bradley Corporation • 215-1510 Rev. D; ECN 07-815 Installation Instructions continued . . . Step 5: Connecting supply 1. Loosen but do not remove the two mounting screws holding the valve...
Page 11 - Step 7: Connecting electrical and supply tubing; Align the valve bracket mounting screws; Figure 7b
11 Express® Lavatory System - MG Series with Battery Infrared Control Installation Instructions MG-2/BIR3 Bradley Corporation • 215-1510 Rev. D; ECN 07-815 8/23/07 Installation Instructions continued . . . Step 7: Connecting electrical and supply tubing WARNING: The MG-2/BIR3 must be connected to th...
Page 12 - Cleaning and Maintenance Instructions; Terreon® and panel maintenance; Always use stainless steel wool or stainless steel brushes.; NOTE: Strongly acidic or caustic cleaners may; Terreon® Bowl, Sprayhead and Pedestal End Cap cleaning
Express® Lavatory System - MG Series with Battery Infrared ControlMG-2/BIR3 Installation Instructions 12 8/23/07 Bradley Corporation • 215-1510 Rev. D; ECN 07-815 Cleaning and Maintenance Instructions IMPORTANT: Strong alkaline or acid-based chemicals and cleansers should not be used to clean the MG...
Page 13 - Assembly of Components; Figure 8; Other replacement parts
13 Express® Lavatory System - MG Series with Battery Infrared Control Installation Instructions MG-2/BIR3 Bradley Corporation • 215-1510 Rev. D; ECN 07-815 8/23/07 Assembly of Components SPRAYHEAD BODY(PART NUMBER VARIES WITH COLOR OF UNIT. CONTACT YOUR LOCAL BRADLEY REP. FOR ASSISTANCE). BOWL(PART ...
Page 14 - Sensor assembly and solenoid valve access; • To access solenoids:; Figure 9
Express® Lavatory System - MG Series with Battery Infrared ControlMG-2/BIR3 Installation Instructions 14 8/23/07 Bradley Corporation • 215-1510 Rev. D; ECN 07-815 Assembly of Components continued . . . Sensor assembly and solenoid valve access • To access solenoids: Using a 5/32" Allen socket wr...
Page 16 - Troubleshooting BIR3 Components; CAUTION: Turn off water supplies to unit before troubleshooting.
Express® Lavatory System - MG Series with Battery Infrared ControlMG-2/BIR3 Installation Instructions 16 8/23/07 Bradley Corporation • 215-1510 Rev. D; ECN 07-815 Troubleshooting BIR3 Components CAUTION: Turn off water supplies to unit before troubleshooting. Problem: An individual operating station...
Page 18 - Thermostatic Mixing Valve Maintenance and Troubleshooting; Problem: Limited water flow; Cause: Dirt and debris have built up in the valve or strainer.; Problem: External leaks in the system; Cause: Thermostat is slowly failing or not working at all.; counterclockwise; increase; the temperature or; clockwise; to; decrease
Express® Lavatory System - MG Series with Battery Infrared ControlMG-2/BIR3 Installation Instructions 18 8/23/07 Bradley Corporation • 215-1510 Rev. D; ECN 07-815 Thermostatic Mixing Valve Maintenance and Troubleshooting NOTE: Before attempting to troubleshoot the valve or disassemble the components...