Page 4 - TOOL SPECIFICATIONS; FASTENER SPECIFICATIONS; MAINTAINING THE TOOL
TOOL SPECIFICATIONS All dimensions in inches unless otherwise specified. -4- 651S5 Description 7/16” Crown Stapler Operation Pressure Range 70-120 PSI (4.9 to 8.43kg/cm 2 ) Fastener Type 16S5 & 17S5 Series Staples Fastener Gauge 16 & 17 Gauge Fastener Range 1” to 2” (25mm to 50mm) Magazine C...
Page 5 - OPERATING MODES; HOW TO CHANGE OPERATING MODES:
-5- OPERATING MODES Always disconnect air supply before making adjustments as accidental actuation mayoccur, possibly causing injury. BOSTITCH OFFERS TWO MODES OF OPERATION FOR THIS SERIES TOOL. CONTACT TRIP: The common operation procedure on “Contact Trip” tools is for the operator to contact the w...
Page 6 - AIR SUPPLY AND CONNECTIONS; LUBRICATION; COLD WEATHER OPERATION:
-6- AIR SUPPLY AND CONNECTIONS Do not use oxygen, combustible gases, or bottled gases as a power source for this tool astool may explode, possibly causing injury. FITTINGS: Install a male plug on the tool which is free flowing and which will release air pressure from the tool whendisconnected from t...
Page 7 - LOADING THE 651 STAPLER; LOADING THE 651 SERIES STAPLERS:
-7- LOADING THE 651 STAPLER EYE PROTECTION which conforms to ANSI specifications and provides protection againstflying particles both from the FRONT and SIDE should ALWAYS be worn by the operator andothers in the work area when connecting to air supply, loading, operating or servicing this tool. Eye...
Page 8 - FASTENER DEPTH CONTROL ADJUSTMENT; TO ADJUST THE FASTENER DEPTH CONTROL:
FASTENER DEPTH CONTROL ADJUSTMENT Always disconnect air supply: 1) Before making adjustments; 2) When servicing the tool; 3)When clearing a jam; 4) When tool is not in use; 5) When moving to a different work area, asaccidental actuation may occur, possibly causing injury. The Fastener Depth Control ...
Page 9 - TOOL OPERATION; BEFORE HANDLING OR OPERATING THIS TOOL:; OPERATION
-9- TOOL OPERATION EYE PROTECTION which conforms to ANSI specifications and provides protection againstflying particles both from the FRONT and SIDE should ALWAYS be worn by the operator andothers in the work area when connecting to air supply, loading, operating or servicing thistool. Eye protectio...
Page 10 - JAM CLEARING PROCEDURE
JAM CLEARING PROCEDURE Disconnect tool from air supply before clearing a jam, making adjustments or beforeattempting any part assembly or disassembly. On occasion staples can jam in the nose of a pneumatic stapler. This can be caused by striking a metalplate in the wall, drywall screw, or some other...
Page 11 - TOOL OPERATION CHECK; MAINTAINING THE PNEUMATIC TOOL; ASSEMBLY PROCEDURE FOR SEALS:
-11- TOOL OPERATION CHECK CAUTION: Remove all fasteners from tool before performing tool operation check. 1. CONTACT TRIP OPERATION: A. With finger off the trigger, press the contact trip against the work surface. THE TOOL MUST NOT CYCLE. B. Hold the tool off the work surface, and pull the trigger. ...
Page 12 - TROUBLE SHOOTING; PROBLEM
-12- TROUBLE SHOOTING PROBLEM CAUSE CORRECTION T Trriig gg ge err vva allvve e h ho ou ussiin ng g lle ea akkss a aiirr O-ring cut or cracked . . . . . . . . . . . . . . . . . . . . .Replace O-ring T Trriig gg ge err vva allvve e sstte em m lle ea akkss a aiirr O-ring/seals cut or cracked . . . . . ...
Page 13 - AVAILABLE ACCESSORIES
AVAILABLE ACCESSORIES -13- 651-RB1 651 O-RING KIT TVA6 TRIGGER VALVE KIT PREMOIL-4OZ PREMIUM PNEUMATIC TOOL OIL 16S5 SERIES STAPLES VSA5 VINYL SIDING ADAPTER PRO-3850 & PRO-1450 PREMIUM POLYURETHANE AIR HOSE