Page 2 - IMPORTANT NOTES FOR INSTALLATION AND OPERATION; Keep the appliance area free and clear from combustibles.
2 IMPORTANT NOTES FOR INSTALLATION AND OPERATION This is the safety alert symbol. It is used to alert you to potentialpersonal injury hazards. Obey all safety messages that follow thissymbol to avoid possible injury or death. WARNING: Improper installation, operation, adjustment, alteration,service ...
Page 4 - SERVICE CONNECTIONS – SN-5G; WATER QUALITY STATEMENT
4 1.0 SERVICE CONNECTIONS – SN-5G MIN. 4 [102] 16 [406] 1 [25 ] 1. 75 [ 44] 4 [102] 40. 38 [1026 ] 5 [ 127] 12 [30 5] SAFETY RELIEF VALVE 23. 19 [58 9] G C D 16.7 5 [ 425 ] 32 [81 3] 9 [229] 1. 12 [29 ] 24 [610] 5.25 [133] 1.75 [44] 3 [76] SAFETY RELIEF VALVE 3.50 [89] C G D DIMENSIONS ARE IN INCHES...
Page 6 - GENERAL; Natural Gas
6 2.0 INSTALLATION GENERAL Installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 , or the Natural Gas and Propane Installation Code, CSA B149.1 , as applicable. 1. The appliance and its individual shut off valve must be dis...
Page 10 - STRAINERS and FILTERS will NOT remove minerals from the water.
10 COLD WATER CONDENSER The steamer is equipped with a cold water condenser in the rear of the cooking chamberwhich helps to condense the steam prior to discharge into drain. The steamer freelyvents itself by the negative pressure created by the condensate water drainage. Thisnegative pressure preve...
Page 11 - PERFORMANCE CHECK; Check that “Ignition” light comes on and cycles “ON” and “OFF”.
11 3.0 PERFORMANCE CHECK Once the steamer is installed and all mechanical connections have been made,thoroughly test the steamer before operation. 1. Check that proper water, drain and electrical and gas connections have been made. 2. Turn main power switch ON. After approximately 19 minutes, the “R...
Page 13 - LIGHTING; Generator tank will begin filling with water.; SHUTDOWN; Set timer to “OFF” position and leave door slightly open.; COMPLETE SHUTDOWN
13 WARNING: In the event a gas odour is detected, shut down equipment atthe main shut off valve and contact the local gas company or gas supplierfor service. LIGHTING 1. Ensure power, gas and water supply is on. 2. Turn power switch “ON”. 3. Generator tank will begin filling with water. 4. Once wate...
Page 15 - Remove pans and racks from compartment and wash in sink.; Do not apply food; Leave door slightly open when steamer is not in use.
15 5.0 PERIODIC MAINTENANCE NOTICE: As a safety precaution, disconnect the power supply during cleaningor servicing. CLEANING At the end of each day, or between cooking cycles if necessary: 1. Turn main power switch OFF. 2. Remove pans and racks from compartment and wash in sink. 3. Wash compartment...
Page 16 - CLEANING; Clean exterior with a damp cloth and polish with a soft dry cloth.; NOT RECOMMENDED; to use cleaning agents that are corrosive.; NEVER SPRAY WATER INTO ELECTRIC CONTROLS.
16 CLEANING Weekly, or more often if necessary: 1. Clean exterior with a damp cloth and polish with a soft dry cloth. 2. Use a non-abrasive cleaner to remove discolorations. 3. Clean around burner air mixer and orifice if lint has accumulated. Side cover must be removed to clean this area. Monthly: ...
Page 18 - DELIMING PROCEDURE; allow generator to drain.; LEAVE COMPARTMENT DOOR OPEN WHEN NOT; The steamer is now ready for use. Turn off for overnight shutdown.
18 6.0 DELIMING PROCEDURE (For units equipped with this feature) WARNING: Read and follow instructions on the CLR bottle. Use plastic orrubber gloves to avoid skin contact. If CLR comes in contact with skin,rinse with clean water. 1. Drain steam generator by setting power switch to “OFF”, set cookin...
Page 19 - Probe not sensing the water level, will not call for ignition.; Burner produces carbon deposits:
19 7.0 TROUBLESHOOTING ADJUSTMENTS All units are adjusted at the factory. In case of operation problems at initial installation,check type of gas and manifold pressure and compare it with information on rating plate. TROUBLESHOOTING Burner does not come on: 1. Gas supply to unit is “OFF”. 2. Manual ...
Page 20 - Water flows into cooking compartment:; Shortage of circuit at operating probe and body.; Water accumulates in the compartment:; in diaphragm or core tube of valve.; Water not being supplied to generator:; Probes not sensing water, thereby not operating fill solenoid.
20 Water flows into cooking compartment: 1. Shortage of circuit at operating probe and body. 2. Scale build-up on operating probe inside generator. 3. Water fill solenoid valve is open, plugged or defective. These problems are an indication of severe harmful water conditions which should becorrected...