Page 2 - IMPORTANT NOTES FOR INSTALLATION AND OPERATION; Intended for commercial use only. Not for household use.
2 IMPORTANT NOTES FOR INSTALLATION AND OPERATION It is recommended that this manual be read thoroughly and that all instructions befollowed carefully. This is the safety alert symbol. It is used to alert you to potentialpersonal injury hazards. Obey all safety messages that follow thissymbol to avoi...
Page 4 - SERVICE CONNECTIONS; WATER QUALITY STATEMENT
4 1.0 SERVICE CONNECTIONS REAR FLANGED FOOT DETAIL 7/16" [11mm] HOLES ON 2.5 [63] B.C. 2 EQUALLY SPACED Ø S 6 [152] 5.75 [146] 8.75 [222] 28 [711] 16.75 [425] 23 [584] 55 .5 [1410] SB-6E 68 .50 [ 1740] SB-10E 67 [1 70 2] S B- 16 E DIMENSIONS ARE IN INCHES [MM] 0 [0] 3.5 [89] 8.75 [222] 16 .75 [ ...
Page 5 - INSTALLATION INSTRUCTIONS; Set the unit in place and level using a spirit level.
5 2.0 INSTALLATION INSTRUCTIONS Ideally an exhaust system should be located directly above the appliance to exhauststeam and heat generated by the appliance. 1. Set the unit in place and level using a spirit level. 2. Ascertain that a floor drain (open gap) is convenient to the appliance drain. 3. M...
Page 6 - Turn on water and power supply to appliance.
6 3.0 OPERATING INSTRUCTIONS BOILER SECTION Electrically powered steam generators are available with standard boiler controls orASME CSD-1 compliant controls. In addition to the ON/OFF power switch and indicatorpilot light on the standard controls, the CSD-1 controls come with four more indicatorpil...
Page 7 - Water Fill Cycle; Safety Lockout Conditions; High Temperature Condition, Standard Controls
7 3.0 OPERATING INSTRUCTIONS (Continued) Normal Boiler Operating Cycle Water Fill Cycle On the initial filling of the boiler, units equipped with CSD-1 controls require that the“Reset” switch be pressed to initialize the safety lockout circuit. Once the water inthe boiler has reached proper level, t...
Page 8 - OPERATING INSTRUCTIONS; Low Water Condition, Standard Controls; SHUT DOWN
8 3.0 OPERATING INSTRUCTIONS (Continued) High Pressure Condition, CSD-1 Controls A high pressure safety switch is installed on the boiler. Should the pressure exceedthe limit of this device, the boiler will be shut down and switch to a state of lockout.The “Pressure” pilot light (red), and the “Stan...
Page 9 - COOKER SECTION; Close compartment doors and set timer to “1 minute”.
9 COOKER SECTION CAUTION: Live steam and accumulated hot water in the compartment maybe released when the door is opened. Start-up procedures for your steamer must be completed once daily prior to operation(see instruction plate or above for boiler start up procedures). With ready pilot light on,pre...
Page 10 - PERIODIC MAINTENANCE; Never spray water into electric controls.; Refer to warranty terms.
10 4.0 PERIODIC MAINTENANCE Never spray water into electric controls. Be sure to flush your boiler water level control daily. Failure to follow this procedure cancause the control to malfunction resulting in serious boiler damage. The Boiler Water Level Control installed on your boiler requires peri...
Page 11 - CLEANING; Keep exposed cleanable areas of unit clean at all times.
11 CLEANING 1. Keep exposed cleanable areas of unit clean at all times. 2. Thoroughly wash oven cavities, door liners, and pan racks at the end of each day or as required with a mild detergent and water to prevent bacterial growth and odours. 3. Remove drain screens from inside compartment drains. U...
Page 12 - Complete Step 8 twice to assure boiler is completely rinsed.
12 ADJUSTMENTS DESCALING BOILER It is recommended that the boiler be checked every 90 to 120 days for scale build up.Regular maintenance should be carried out at this time. 1. With boiler empty, close manual blowdown valve. If appliance is equipped withAutomatic Blowdown, turn water supply OFF to ap...