Page 2 - IMPORTANT NOTES FOR INSTALLATION AND OPERATION; This manual should be retained for future reference.
2 IMPORTANT NOTES FOR INSTALLATION AND OPERATION It is recommended that this manual be read thoroughly and that all instructions be followedcarefully. This is the safety alert symbol. It is used to alert you to potentialpersonal injury hazards. Obey all safety messages that follow thissymbol to avoi...
Page 4 - DIMENSIONS
4 1.0 SERVICE CONNECTIONS – KLS-DS F E CL D WALL SAFETY RELIEF VALVE 2" VALVE: CLOSED 5.13 [130] OPENED 6.88 [175] 3” VALVE: CLOSED 7.88 [200] OPENED 10.13 [257] S 45° 3.5 [89] A B C OPTIONAL FAUCET ALLOW DIMENSION “D” ADDITIONAL 6 [152] S S 7" ON YOKE TYPE HINGES (STANDARD ON 20-40 GALLON K...
Page 5 - SERVICE CONNECTIONS – KPS-DS
5 SERVICE CONNECTIONS – KPS-DS NOTE: DIMENSIONS F AND G ARE BASED ON Ø2" DRAW-OFF VALVE. OTHER VALVES VARY ACCORDINGLY. 4 HOLES Ø 7/16 [11] EQUALLY SPACED FRONT PEDESTAL DETAIL 45° Ø K WALL CLOSED 5.5 [140] OPENED 7.5[191] SAFETY RELIEF VALVE F D E 45° CL S OPTIONAL FAUCET ALLOW DIMENSION "D...
Page 6 - INSTALLATION INSTRUCTIONS; convenient to the kettle.
6 2.0 INSTALLATION INSTRUCTIONS 1. Select a location to provide drainage directly below the tangent Draw-off Valve. 2. Mark hole locations through flanged adjustable feet on KLS-DS models and through pedestal base on KPS-DS models. Remove kettle. 3. On hole locations marked, drill holes and insert e...
Page 8 - Fill kettle with product to desired level.
8 4.0 OPERATING INSTRUCTIONS CAUTION: THE APPLIANCE AND ITS PARTS ARE HOT. USE CAREWHEN OPERATING, CLEANING OR SERVICING THE APPLIANCE. OPERATING PROCEDURE 1. Ensure that draw-off valve is closed. 2. Fill kettle with product to desired level. 3. Slowly turn the steam control valve ON to full open po...
Page 9 - CLEANING INSTRUCTIONS; CAUTION: Do not use cleaning agents that are corrosive.; Wipe the exterior of the kettle with a clean, damp cloth.; DRAW-OFF VALVE CLEANING
9 5.0 CLEANING INSTRUCTIONS CAUTION: Do not use cleaning agents that are corrosive. WARNING: Disconnect the power supply to the appliance beforecleaning or servicing. WARNING: Never spray water into electric controls or components! CAUTION: The equipment and its parts are hot. Use care whenoperating...
Page 10 - Leave the draw-off valve open when the kettle is not in use.; DAIRY DRAW-OFF VALVE CLEANING; Use a soft cloth or soft brush and clean all surfaces.; WHAT TO DO IF SURFACE RUST APPEARS; and allow one hour before using the appliance to cook.
10 3. Leave the draw-off valve open when the kettle is not in use. DAIRY DRAW-OFF VALVE CLEANING 1. Remove the plug by first removing the handle, then turn the plug to line up with the pin and pull with both hands. It is important to use both hands because the plug is heavy. 2. Put the plug in a pla...
Page 12 - If a leak occurs through the valve stem, replace the “O” ring.
12 6.0 TROUBLESHOOTING MAINTENANCE PREVENTIVE MAINTENANCE No preventive maintenance is required other than adhering to the Cleaning Procedureinstructions. DRAW-OFF VALVE LEAKS If a leak occurs through the valve stem, replace the “O” ring. If the leak can be attributed to faulty sealing occurring bet...
Page 13 - VENTING
13 TROUBLESHOOTING MAINTENANCE (continued) VENTING It is recommended that the “optional” steam trap assembly be installed. This should be plumbedto the exit end of the kettle. The thermostatic trap is a mechanical device that closes on hightemperature and opens when the temperature drops, allowing t...