Page 2 - Document History
R5976426 Title: C YCLOPS User’s Manual ID-no.: R5976426 Date: 2001-12 main issue update chapter 1 new chapter 2 new chapter 3 new chapter 4 new chapter 5 new chapter 6 new chapter 7 new chapter 8 new chapter 9 new chapter 10 new chapter 11 new chapter 12 new chapter 13 new chapter 14 new chapter 15 ...
Page 4 - Revision sheet; • Web
Revision sheet To: Barco Control Rooms GmbH An der Rossweid 5 • D-76229 Karlsruhe • GermanyPhone (49) (721) 6201-0 • Fax (49) (721) 6201-298E-mail [email protected] , Web www.barcocontrolrooms.de BARCO N.V. Projection Systems Noordlaan 5 • B-8520 Kuurne • BelgiumPhone (32) (56) 36-8211 • Fax (32...
Page 5 - Contents
Contents 1 Introduction .................................................................................................................................. 1-1 1.1 How This Manual Is Organized .......................................................................................... 1-2 1.2 Styles An...
Page 9 - Intro d uction
1 Intro d uction This manual describes design, function, operation and maintenance of the modular rear projectionsystem C YCLOPS of BARCO. C YCLOPS is a modular structure to house a 3-panel Poly-Silicon LCD projector. Cyclops 100S has a screen diagonal of approx. 100" (98"), up to 2 units ca...
Page 10 - How Th i s Manual Is Organized
C YCLOPS (2001-12) R5976426 1-2 1.1 How Th i s Manual Is Organized This manual is divided into fifteen chapters: Preliminary Remarks explains the structure of the manual itself and the used typographic styles and symbols. Safetyinformation is provided concerning the operation of systems from BARCO. ...
Page 11 - Styles A nd Symbols; Labels, menus and buttons are printed in the; Condensed; Courier bold; Courier bold
C YCLOPS (2001-12) R5976426 1-3 1.2 Styles A nd Symbols The typographic styles and the symbols used in this document have the following meaning: Arial bold Labels, menus and buttons are printed in the Arial bold font. Condensed Links to both other chapters of this manual and to sites in the Internet...
Page 12 - Safety I nformation; Safetey; General safety instructions
C YCLOPS (2001-12) R5976426 1-4 1.3 Safety I nformation This section describes safety precautions which must be observed when installing a product fromBARCO. Safetey C YCLOPS is built in accordance with the requirements of the international safety standard IEC950, UL1950 and CSA C22.2 No. 950, which...
Page 13 - Ground
C YCLOPS (2001-12) R5976426 1-5 B. Power cord with ANSI 73.11 plug:The wires of the power cord are colored in accordance with the following code: Green/yellow: Ground White: Neutral Black: Line (live) Do not allow anything to rest on the power cord. Do not locate this product where persons willwalk ...
Page 14 - On Servicing
C YCLOPS (2001-12) R5976426 1-6 On Servicing Do not attempt to service this device yourself, as opening or removing covers may expose you todangerous voltage potential and risk of electric shock! Refer all projector service to a qualifiedBARCO service center.Adjust only those controls that are cover...
Page 15 - Abbr e viated Summary
2 Abbr e viated Summary This chapter provides a summary of the system components and characteristics.
Page 16 - provides optimum solutions which also satisfy the highest; can be combined to achieve an impressive Display Wall. C; is designed for long term op-; Proper t ies of C; High, Constant Reading Accuracy Over the Complete Display Panel
C YCLOPS (2001-12) R5976426 2-2 2.1 Design High-quality and large-area displaying of monitor contents is becoming increasingly important inconference and presentation theaters, at exhibitions, in public areas of insurance companies, banks,hotels or transport services. Personal computers are primaril...
Page 17 - Desig n and Function
3 Desig n and Function This chapter provides a technical description of the equipment listing the fundamental characteris-tics and functional principles. Knowledge of this section is not absolutely essential for operation.
Page 18 - Compo n ents of Cyclops
C YCLOPS (2001-12) R5976426 3-2 3.1 Compo n ents of Cyclops C YCLOPS consists of the following components: Mechanical structure: the metal housing incorporates the projector, mirror and screen. Projector: The projector employed in C YCLOPS is based on most modern 3-panel poly-Silicon LCD technology....
Page 19 - Fresnel-Lenticular Screen; Fresnel Lens
C YCLOPS (2001-12) R5976426 3-3 Figure 3-1 Poly-Silicon TFT-LCD The LCD panels are based on Poly-Silicon technology. Poly-Silicon material consists of nu-merous small crystals leading to small circuitry. The results are a big aperture (ratio of a pixel’sshutter area to it’s total area), high speed a...
Page 20 - Diffusion Screen
C YCLOPS (2001-12) R5976426 3-4 Diffusion Screen Diffusion screens distribute the projected light evenly over a wide horizontal and vertical viewingarea. The reflection value (gain) is 1.They are appreciated for their versatility. It is a perfect choicefor any application which requires a wide viewi...
Page 21 - Loca t ion and Functions of Control; This chapter provides an overview about the controls of Cyclops.
4 Loca t ion and Functions of Control This chapter provides an overview about the controls of Cyclops.
Page 23 - Contro l Panel Terminology
C YCLOPS (2001-12) R5976426 4-3 12 IR-AcknowledgedIR-Received IR-Signals are recognizedIR-Signals are received but not recognized by the pro-jector 13 Projector mode indication indicates the status of the projectorLight off: power switch is not pressed Red light: power switch is pressed, projector i...
Page 24 - This remote control unit (; user to control the projector remotely.
C YCLOPS (2001-12) R5976426 4-4 4.3.2 Remote control This remote control unit ( RCU ) includes a battery powered infrared (IR) transmitter that allows the user to control the projector remotely. Figure 4-3 IR Remote Control Unit (RCU) This remote control is used for source selection, control, adapta...
Page 25 - Termino l ogy of keypad and RCU controls
C YCLOPS (2001-12) R5976426 4-5 4.3.3 Termino l ogy of keypad and RCU controls 1 Function keys have no function for this projector 2 ADJ ADJUST key, to enter or exit the adjustment mode. 3 Address key (recessed key), to enter the address of the projector (between 0 and9). Press the recessed address ...
Page 26 - Conn e ctions; This chapter explains the various interfaces of C
C YCLOPS (2001-12) R5976426 5-1 5 Conn e ctions This chapter explains the various interfaces of C YCLOPS .
Page 27 - Power c onnection
C YCLOPS (2001-12) R5976426 5-2 5.1 Power c onnection 5.1.1 AC Pow e r (mains) cord connection I 0 RC RS 232 IN RS 232 OUT Comm. Port IEE 1394 TRIG MOUSE VIDEO S-VIDEO SDI SDO R G B H/C V COMPUTER MONITOR AUDIO IN AUDIO IN AUDIO IN AUDIO OUT A B C 1 2 3 4 5 6 Use the supplied power cord to connect y...
Page 29 - Installation Mode
C YCLOPS (2001-12) R5976426 5-4 5.1.9 Set up o f the input selection: Press ENTER to start up the adjustment mode. Press the cursor key up or down to select 'Installation' . Press ENTER to display the Installation menu . Press the cursor key up or down to select 'Input Slots' . Press ENTER to displa...
Page 30 - Configuration of the 5-cable input
C YCLOPS (2001-12) R5976426 5-5 Configuration of the 5-cable input The configuration has to be done on the 'Input slot' menu. To change the signal format: Press ADJUST or ENTER to start up the Adjustment mode. Push the cursor key up or down to select Installation Press ENTER . Press the cursor key u...
Page 33 - Set up of the Baud Rate for Communication with a Computer:
C YCLOPS (2001-12) R5976426 5-8 5.1.16 Commu n ication Connections The following communication connections are available: RS232 in / RS232 out. Comm port for communication with peripheral (switchable between PPM and RC5) RC for remote cable connection with the RCU. MOUSE to control a PC with the pro...
Page 35 - Cont r olling
C YCLOPS (2001-12) R5976426 6-10 6 Cont r olling The projector can be controlled with the RCU the hardwired RCU (cable is not included) the local keypad Controlling the projector with the RCU and the hardwired RCU is equal.
Page 36 - RCU us e d in a hardwired configuration
C YCLOPS (2001-12) R5976426 6-11 6.1 RCU us e d in a hardwired configuration Connections: Plug one end of the remote cable in the connector on the bottom of the RCU Plug the second side in the connector in the front panel of the projector labelled 'RC' . 6.2 How to use the RCU? Point the front of th...
Page 38 - Sound c o ntrols with direct access
C YCLOPS (2001-12) R5976426 6-13 6.3.5 Sound c o ntrols with direct access When a sound control is pressed, a text box with a bar scale, icon and function name of the con- trol, e.g. 'volume ...' appears on the screen (only if TEXT is ON ). The length of the bar scale indi- cates the current memoriz...
Page 39 - Start Up of the Adjustment Mode; or; key to enter the
C YCLOPS (2001-12) R5976426 7-1 7 Start Up of the Adjustment Mode All source parameters, picture and audio tuning, and geometry are made while in the 'Adjustment Mode' . Press the ADJUST or ENTER key to enter the 'Adjustment mode' .
Page 40 - Adjust m ent mode
C YCLOPS (2001-12) R5976426 7-2 7.1 Adjust m ent mode You are now in the 'Adjustment Mode' . The cursor key ( RCU ) or '+ or '-' keys (local keypad ) are used to make menu selections and also for adjustments. The ENTER and EXIT keys are used to move forward and backward through the menu structure. T...
Page 41 - Rand o m Access Adjustment Mode
C YCLOPS (2001-12) R5976426 8-1 8 Rand o m Access Adjustment Mode To start up the Random Access Adjustment Mode: push the cursor key up or down to highlight 'Random Access' and then press ENTER The Random Access menu comprises four submenus each of which gives access to the various settings and comm...
Page 44 - method 3
C YCLOPS (2001-12) R5976426 8-4 8.1.2 Edit File The Edit file menu makes it possible to change the settings of the file according to the real settings of the connected source. Consult the source specification before entering the data.To start up the EDIT menu : Push the cursor key up or down to high...
Page 45 - How to find the correct values for the displayed item?
C YCLOPS (2001-12) R5976426 8-5 How to find the correct values for the displayed item? During the installation of a file with LOAD , the horizontal period, the total number of vertical lines and the interlaced mode are automatically measured and filled in the menu table. These values willbe availabl...
Page 48 - File Sort
C YCLOPS (2001-12) R5976426 8-8 8.1.6 File Opt i ons Push the cursor key up or down to highlight 'File Options' . Press ENTER . The option selection menu will be displayed. File Sort Press ENTER to toggle between [ name ] and [ index ] [ name ]: The files in the file list will be sorted on the file ...
Page 55 - Insta l lation Mode
C YCLOPS (2001-12) R5976426 9-1 9 Insta l lation Mode To start up the Installation Mode , push the cursor key up or down to highlight 'Installation Mode' and then press ENTER . The following items can be selected in the Installation mode : Input slots to set up the input priority 800 Peripheral to s...
Page 57 - Output module selection
C YCLOPS (2001-12) R5976426 9-3 9.2 800 Pe r ipheral Output module selection When a RCVDS05 is connected to the projector, the type of output module of this RCVDS05 has to be defined in the 800 peripheral menu . The type of output module can be: standard output module or 5 cable output module. To de...
Page 58 - Interna l Patterns
C YCLOPS (2001-12) R5976426 9-4 9.5 Interna l Patterns The projector is equipped with different internal patterns which can be used for measurement pur-poses.To select an internal pattern, handle as follow: Push the cursor key up or down to highlight 'Internal Patterns' . Press ENTER to select. The ...
Page 59 - Lens A d justments
C YCLOPS (2001-12) R5976426 9-5 9.6 Lens A d justments All lens adjustments are motorized and can be adjusted with the RCU.The following items can ce adjusted Zoom/Focus Shift When the Selection key is pressed, the zoom/focus/shift menu will be displayed immediately. To focus the image: Push the up ...
Page 60 - Interna l Patterns
C YCLOPS (2001-12) R5976426 9-6 9.8 Interna l Patterns The projector is equipped with different internal patterns which can be used for measurement pur-poses.To select an internal pattern, handle as follow: Push the cursor key up or down to highlight 'Internal Patterns' . Press ENTER to select. The ...
Page 61 - 0 Servi c e Mode
C YCLOPS (2001-12) R5976426 10-1 10 Servi c e Mode To start up the Service Mode : push the cursor key up or down to highlight 'Service' press ENTER . Some items in the Service mode are password protected (when the password function is active). Enter the password to continue. All other password prote...
Page 62 - Identifi c ation; Change Projector; Chang e Password
C YCLOPS (2001-12) R5976426 10-2 10.1 Identifi c ation To display the Identification screen : Push the cursor key up or down to highlight 'Identification' . Press ENTER to display the Identification screen. The Identification screen gives an overview of: type of projector Barcoreality Helios project...
Page 63 - Chang e Language
C YCLOPS (2001-12) R5976426 10-3 10.3 Chang e Language To change the language of the control software: Push the cursor key up or down to highlight 'Change Language' . Press ENTER to display the Change Language menu . Push the cursor key up or down to highlight the desired language. Press ENTER to ch...
Page 64 - Chang e Baudrate PC
C YCLOPS (2001-12) R5976426 10-4 10.5 Chang e Baudrate PC The communication speed between projector and computer, e.g. PC or MAC, has 8 possiblespeeds. The baud rate speed can be software set. Handle as follows: Push the cursor key up or down to highlight 'Change Baudrate PC' . Press ENTER to displa...
Page 65 - Panel A d justment
C YCLOPS (2001-12) R5976426 10-5 10.8 BARCO logo The BARCO logo can be added to the image, in overlay or on a background, on any place on thescreen.To add the BARCO logo or to change a setting in the BARCO logo menu : Push the cursor key up or down to highlight 'BARCO logo' . Press ENTER to display ...
Page 66 - Preset I nput Balance
C YCLOPS (2001-12) R5976426 10-6 10.10 Uniform i ty Changing these settings may seriously affect the performance of the projector Push the cursor key up or down to highlight 'Uniformity' . When Uniformity is selected in the Service Mode selection menu , the following warning will be displayed : Unif...
Page 67 - 1 Main t enance and Servicing
11 Main t enance and Servicing C YCLOPS requires very little maintenance and servicing. Maintenance operations are nevertheless necessary at regular intervals to guarantee good operational performance.This chapter describes maintenance and servicing of C YCLOPS . Only authorized personnel should car...
Page 68 - The following cleaning solutions can be used:
C YCLOPS (2001-12) R5976426 11-2 11.1 Genera l For safety reasons, all servicing, including replacement of the lamp, is restricted to authorized per-sonnel only! Only authorized personnel should carry out maintenance work! Never open the access cover without first disconnecting the power supply cord...
Page 69 - 2 Tech n ical Data
12 Tech n ical Data This chapter provides tabular overviews about the technical details of C YCLOPS .
Page 70 - Techni c al Data of Optical System
C YCLOPS (2001-12) R5976426 12-2 12.1 Genera l Data characteristic specification dimensions screen widthscreen heighttotal depth 98” diagonal1943.5 mm | 76.5 in.1544 mm | 61.2 in.1487 mm | 58.5 in. weighttotal weight(incl. projector, mirror, screen) weight of cladding 166 kg | 366 lbs 25 kg | 55.11 ...
Page 71 - Techni c al Data Of Electrical System
C YCLOPS (2001-12) R5976426 12-3 12.3 Techni c al Data Of Electrical System characteristic specification AC power supply 95VAC .... 230VAC ± 10% mains frequency 50....60 Hz power consumption Max. 300 W with 230VAC Table 12-3 12.3.1 Slot 1: 5 cable input, 5×BNC 1 2 1 Signal 2 Shield Connector name R ...
Page 73 - title
C YCLOPS (2001-12) R5976426 12-5 12.4 Parts L i st 12.4.1 Scope o f Delivery of R9831150 order No. designation R9831150 Cyclops, modular rear projection unit, incl. projector anddouble element screen (fresnel-lenticular) (SXGA resolu-tion), without cladding R9831155 Cyclops, modular rear projection ...
Page 74 - 3 Troub l eshooting; When faults occur with C; which are not described below please contact BARCO.
13 Troub l eshooting When faults occur with C YCLOPS which are not described below please contact BARCO.
Page 75 - Technical Data Of Electrical System
C YCLOPS (2001-12) R5976426 13-2 13.1 Faults Faults cause/steps no display: lamp not ignited and fan of theillumination unit not running The equipment is not connected to power sup-ply. It must be supplied with suitable voltage(see 12.3 Technical Data Of Electrical System )! Power switch is off. Swi...
Page 76 - Feel free to contact us if you have any further questions!
C YCLOPS (2001-12) R5976426 13-3 13.2 Contac t 13.2.1 Hot Lin e Feel free to contact us if you have any further questions! Barco Control Rooms GmbH An der Rossweid 5 • D-76229 Karlsruhe • GermanyPhone (49) (721) 6201-0 • Fa× (49) (721) 6201-298E-mail [email protected] , Web www.barcocontrolroom...
Page 77 - 4 Appe n dix A: Standard Source Set Up Files
14 Appe n dix A: Standard Source Set Up Files Name: name of file, contains the settings Resolution: image resolution, when followed by ...I means interlaced.FVERT/Hz: vertical frame frequency of the sourceFHOR/kHz: horizontal frequency of the source.FPIX/MHz: pixel frequencyPTOT: total pixels on one...
Page 78 - MUSE
C YCLOPS (2001-12) R5976426 14-2 name resolution Fvert/Hz Fhor/kHz Fpix/MHz ptot pact ltot lact MAC_6 832 × 624 74,546 49,722 57,280 1152 832 667 624 MAC_7 1024 × 768 74,907 60,150 80,000 1330 1024 803 768 MAC_LC 640 × 480 66,619 34,975 31,338 896 640 525 480 MAC_POR 640 × 870 74,996 68,846 57,280 8...
Page 80 - Project o r without any 800 peripheral connected.; Select the source between 1 and 6.; Project o r with a 800 peripheral connected.
C YCLOPS (2001-12) R5976426 15-4 15 Appe n dix B: Source Numbers 81 - 86 And 91 - 96 15.1 Project o r without any 800 peripheral connected. The source numbers 81 - 86 and 91 - 96 do not correspond to physical inputs. An additional ad-justment file can be created for these source numbers. This file c...