Page 3 - Safety instructions
User manual MIVD 1218 3 Safety instructions Read the safety and operating instructions before operating the apparatus. Retain safety and operating instructions for future reference. Adhere to all warnings on the apparatus and in the operating instructions manual. Follow all instructions for operatio...
Page 4 - Contents
User manual MIVD 1218 4 Contents Safety instructions .............................................................................................. 3 Contents ............................................................................................................. 4 1. Overview.....................
Page 8 - menus and changing values in the menus; Connector not used
User manual MIVD 1218 8 (3) Control wheel for navigating through the on-screen display (OSD) menus and changing values in the menus RS232 DVI VI DEO C S/ HS VS (S E RV ICE ONLY ) Power (4) Control (rs-232) connector Note: To comply to EMC regulations, the used RS-232 cable must be provided with a fe...
Page 13 - Important: When using the display for the first time, perform the
User manual MIVD 1218 13 2.6. Tilt and swivel positioning (model with tilt & swivel foot option) Adjust the position of the panel for best viewing conditions. The display foot allows adjusting the horizontal viewing angle, vertical viewing angle and panel height. 2.7. Starting up Proceed as foll...
Page 15 - To change contrast or brightness manually:
User manual MIVD 1218 15 a) To save the changes, click and hold the control wheel for a few seconds. b) To exit the menus without saving the changes: 1 Turn the control wheel. The check mark in the menu changes into a cross ( 2 ). 2 Click and hold the control wheel for a few seconds. When you make a...
Page 17 - Click and hold the control wheel for a few seconds to exit the; When do you need to calibrate?
User manual MIVD 1218 17 2 Click the control wheel to enter the menu. 3 Turn the control wheel to change the light output value. 4 Click the control wheel to confirm the change of the value. 5 Click and hold the control wheel for a few seconds to exit the menu. Note: Unlike the contrast and brightne...
Page 19 - General information; mode
User manual MIVD 1218 19 Note: The calibration of the video levels determines the calibrated position or default setting of contrast and brightness. The black level calibration determines the brightness, the white level calibration determines the contrast. 3.5. Getting information The Information me...
Page 20 - Timing information; frequency; Required test pattern; Turn the control wheel to display the Geometry menu.
User manual MIVD 1218 20 Lifetime .....................Indicates the total time the display has been operating, including the time in power-saving mode * Not in DVI mode Timing information V.Freq.......................The currently measured vertical sync frequency H.Freq ......................The cu...
Page 22 - Turn the control wheel to select one of the categories: Input; Input Selection
User manual MIVD 1218 22 3 Turn the control wheel to select one of the categories: Input selection, Test Pattern, Synchr. Sampl, Lookup Tables, Filter, Power Led, ALC active, or de-interlacing. 4 Click the control wheel to enter the selected settings menu. 5 Turn the control wheel to change the sett...
Page 23 - display is used to replace a CRT display.; Power Led; ** Only when Portrait Accelerator is installed; Select the desired option:
User manual MIVD 1218 23 DICOM .....................Select a DICOM lookup table for most medical viewing applications. The DICOM function results in more visible grayscales in the images. CRT ..........................Select a CRT (gamma) lookup table in case the display is used to replace a CRT dis...
Page 24 - * Not in DVI mode – Visible only when the input signal is interlaced; and moving parts; CAL options; Here you can change parameters for phase and level calibration
User manual MIVD 1218 24 Auto ..........................The display selects portrait or landscape reproduction automatically, depending on the orientation of the panel. Portrait ......................The image is reproduced in portrait orientation. Landscape: The image is reproduced in landscape ori...
Page 28 - Remove the bezel with glass panel.; Cleaning instructions:; - Do not apply liquid directly to the LCD surface as excess liquid
User manual MIVD 1218 28 4. Maintenance Panel Take care not to damage or scratch the panel. Clean with a soft woolen or cotton towel. Use a watery solution or a mild commercial glass-cleaning product. Cabinet Do not use chemical cleaning products, benzene, toluene, xylene or other solvents. Clean wi...
Page 29 - Calibration not successful; - Check the quality of the signal source and signal cables. Poor; Pixel Faults
User manual MIVD 1218 29 5. Troubleshooting Calibration not successful After an unsuccessful calibration, the message “Failed” appears on the screen. Possible solutions: - Use another test pattern for performing the calibration. The text in § 3.4, Calibrating the display , explains what test pattern...
Page 30 - Technical specifications
User manual MIVD 1218 30 6. Technical specifications GEOMETRY • Screen size: 46 cm (18.1") • Display area: 359 mm x 287 mm (14.1" x 11.3") • Aspect ratio: 5:4 VISUAL PERFORMANCE General • Pixel arrangement: sub- pixel vertical stripes • Pixel pitch: 0.2805 mm x 0.2805 mm (0.011" x 0....
Page 31 - CONTROLS; • On-Screen Display; POWER SUPPLY; • Mains input voltage:; APPROVALS
User manual MIVD 1218 31 CONTROLS • On-Screen Display (OSD) • Rotary / push control wheel to navigate through the OSD • RS232 POWER SUPPLY • Mains input voltage: automatic 90 - 264 Vac Freq. 50/60 Hz APPROVALS CE, IEC601-1, UL 2601-1, CUL 2601-1 DIMENSIONS H x W x D: 371 x 444 x 90 mm (14.6 x 17.5 x...