990-2820A Smart-UPS® VT ISX 30-40 kVA, 400 V Operation 1 About this Manual This manual is intended for the users of the Smart-UPS ® VT ISX. It refers to important safety warnings and instructions, gives an introduction to the display interface, and provides information on operation, load connection,...
Page 5 - Contents
Contents 990-2820A Smart-UPS VT® ISX, 30-40 kVA, 400V, Operation i Safety ................................................................................ 1 Overview........................................................................... 2 System Overview . . . . . . . . . . . . . . . . . . . . ....
Page 7 - Safety
990-2820A Smart-UPS® ISX 30-40 kVA, 400V Operation 1 Safety Warn in g All safety instructions in Safety Sheet 990-2822A shall be read, understood and followed prior to handling/using the system. Failure to do so could result in equipment damage, serious injury, or death.
Page 8 - Overview; System Overview
2 Smart-UPS® ISX 30-40 kVA, 400V Operation 990-2820A Overview System Overview With internal batteries For external batteries Front view Rear view With front panel LOAD ON LOAD ON ON-BA ON-BATT BYP BYPASS ASS FAULT ESC ?
Page 9 - System Components; Opening front and rear doors
990-2820A Smart-UPS® ISX 30-40 kVA, 400V Operation 3 System Components Opening front and rear doors The UPS has a lock mechanism on the front and rear doors. The key is provided with the manual for the Network Management Card. To open the front door, pull out the lower end of the handle and turn i...
Page 10 - Network Management Card with Environmental Monitor
Overview – System Components 4 Smart-UPS® ISX 30-40 kVA, 400V Operation 990-2820A User interface (front) Network Management Card with Temperature Sensor: used for remote system control and monitoring, e-mail notifications etc. For configuration and use, refer to the separate user manual – Network ...
Page 11 - Battery Module; One Battery Module consists of 4 Battery Units.
990-2820A Smart-UPS® ISX 30-40 kVA, 400V Operation 5 User interface area (rear) The Power Distribution Unit is installed behind the rear doors of the UPS. Battery Module One Battery Module consists of 4 Battery Units. Model: Serial: BATTER Y UNIT Model: Serial: BATTER Y UNIT Model: Serial: BATTER Y ...
Page 12 - The Display
6 Smart-UPS® ISX 30-40 kVA, 400V Operation 990-2820A The Display C au tion The display provides access to more functions than described in this manual. In order to avoid unwanted load impacts these functions should not be accessed without the assistance of APC Customer Support. For APC Worldwide Cus...
Page 13 - Menu tree
Overview – The Display 990-2820A Smart-UPS® ISX 30-40 kVA, 400V Operation 7 Menu tree The menu tree provides a quick overview of the user interface functions. If you get beyond the functions des cri bed in the menu tree, do not proceed. Press ESC to go back. Note If you get beyond the functions desc...
Page 14 - Basic display navigation principles; Press; ENTER; to open the; Control functions; Switch the UPS into Bypass/out of Bypass; All illustrated display screens are examples only!; procedure if you need to de-energize the UPS in
Overview – The Display 8 Smart-UPS® ISX 30-40 kVA, 400V Operation 990-2820A Basic display navigation principles On the display, press ESC until you get to the Overview Screen, which provides you with basic system status information.Press UP, DOWN arrows to navigate with the selector arrow and view a...
Page 15 - Switch out of bypass.; Status views; Voltage on all phases.
Overview – The Display 990-2820A Smart-UPS® ISX 30-40 kVA, 400V Operation 9 Switch load ON. 1. From the Main Menu, select Control and press ENTER 2. Use UP/DOWN key to navigate to Turn Load ON , and press ENTER 3. Select YES, Turn Load ON Switch into bypass. 1. From the Main Menu, select Control and...
Page 16 - Date; Logging
Overview – The Display 10 Smart-UPS® ISX 30-40 kVA, 400V Operation 990-2820A Alarm thresholds. Load: An alarm will be set when the load is above the threshold level.Runtime: An alarm will be set when the runtime is below the threshold level. Clock set-up From the Setup screen on the Main Menu, you c...
Page 18 - Alarm threshold
Overview – The Display 12 Smart-UPS® ISX 30-40 kVA, 400V Operation 990-2820A Alarm threshold If the load level exceeds the preprogrammed threshold, the UPS will display a warning. Example: To change the Alarm Thresholds: 1. Select Setup from the Main Menu 2. Select Alarms from the Setup Menu 3. Pres...
Page 19 - Diagnostics screen
Overview – The Display 990-2820A Smart-UPS® ISX 30-40 kVA, 400V Operation 13 To change the beeper setup, select Beep at and press ENTER. You now have the following options: • Never : If you select this setting, the Beeper will be active at internal UPS errors only. • PwrFail+30 : If you select this ...
Page 20 - Operation; Operation Modes; Normal operation
14 Smart-UPS® ISX 30-40 kVA, 400V Operation 990-2820A Operation Operation Modes The UPS has four different operation modes. If the installation includes a Maintenance Bypass Panel, bypass mode and test mode will also be available. Normal operation During normal operation, the UPS converts utility po...
Page 21 - Operation Procedures; Turn into mechanical bypass using the Mechanical Bypass Lever; Control
990-2820A Smart-UPS® ISX 30-40 kVA, 400V Operation 15 Operation Procedures Turn into mechanical bypass using the Mechanical Bypass Lever From the Main Menu, select Control and press ENTER Use UP/DOWN key to navigate to UPS into Bypass and press ENTER Use UP/DOWN key to navigate to YES, confirm...
Page 22 - Turn into normal operation (from mechanical bypass operation); YES
Operation – Operation Procedures 16 Smart-UPS® ISX 30-40 kVA, 400V Operation 990-2820A Turn into normal operation (from mechanical bypass operation) Verify the presence of utility supply. The UPS will start up and perform a self test (see Restart Procedure). Ensure that no error messages appea...
Page 23 - Configuration; Connection of Load to the PDU; Connecting load to the PDUs
990-2820A Smart-UPS® ISX 30-40 kVA, 400V Operation 17 Configuration Connection of Load to the PDU Connecting load to the PDUs Connecting 1-phase load to PDU I Set the applicable breaker to the OFF position. Guide the load cable down through the top hole. Insert the plug from the load into the ...
Page 24 - Connecting 3-phase load to PDU II
Configuration – Connection of Load to the PDU 18 Smart-UPS® ISX 30-40 kVA, 400V Operation 990-2820A Connecting 3-phase load to PDU II Set the applicable breaker set to the OFF position. Guide the load cable down through the top hole. Lift up the receptacle cover and connect the load to the CEE...
Page 25 - PDU output breaker ratings
Configuration – Connection of Load to the PDU 990-2820A Smart-UPS® ISX 30-40 kVA, 400V Operation 19 Disconnecting load from the PDU(s) To disconnect the load, set the applicable breaker(s) to the OFF position. PDU output breaker ratings Rear of unit Ambient temperature in front of unit º C Nominal b...
Page 26 - Parts Replacement; How to determine if you need a replacement part; contact APC Customer Support.; How to return parts to APC; Damages sustained in transit are not covered under warranty.
20 Smart-UPS® ISX 30-40 kVA, 400V Operation 990-2820A Parts Replacement How to determine if you need a replacement part To determine if you need a replacement part, contact APC Customer Support and follow the procedure below so that the APC Customer Support representative can assist you promptly. 1....
Page 27 - How to remove Battery Modules; Two people to lift a component weighing between 18 – 32 kg.
Configuration – Parts Replacement 990-2820A Smart-UPS® ISX 30-40 kVA, 400V Operation 21 How to remove Battery Modules Follow the below procedures if you need to change or add a Battery Module, e.g. if you receive a display message reporting a bad battery, or if you need to add batteries for increase...
Page 28 - How to install a Battery Module; Install the Battery Modules in the lowest available bay.; Troubleshooting
Configuration – Parts Replacement 22 Smart-UPS® ISX 30-40 kVA, 400V Operation 990-2820A To release the battery from the lock mechanism, one person gently pushes the battery upwards again and pulls it out, while the other person supports the battery. How to install a Battery Module If additional ba...
Page 29 - How to replace a Network Management Card; Carefully pull out the card.
Configuration – Parts Replacement 990-2820A Smart-UPS® ISX 30-40 kVA, 400V Operation 23 How to replace a Network Management Card Loosen the 2 torx screws (one each side of the card). Carefully pull out the card. Install the new card. Reattach the 2 torx screws. 10/100Base-T Probe AP9619 Netw...
Page 30 - Display messages; Display message
24 Smart-UPS® ISX 30-40 kVA, 400V Operation 990-2820A Troubleshooting This section lists the status and alarm messages that the UPS might display. The messages are listed in alphabetical order, and a suggested corrective action is listed with each alarm message to help you troubleshoot problems. Dis...
Page 33 - Restart; Power application; Set the utility breaker to the ON position.
990-2820A Smart-UPS® ISX 30-40 kVA, 400V Operation 27 Restart Power application Set the utility breaker to the ON position. If your installation includes an XR Battery Enclosure (SUVTBXR2B6/SUVTBXR6B6) with a DC disconnect switch, set the DC disconnect switch to the ON position. After system boo...
Page 34 - Voltage confirmation; Confirm Voltage
Restart – Parts Replacement 28 Smart-UPS® ISX 30-40 kVA, 400V Operation 990-2820A Voltage confirmation At the restart, the display will prompt you through the following screens: When the Confirm Voltage prompt appears on the screen, select desired voltage and press ENTER. When the prompt Apply l...
Page 36 - APC Worldwide Customer Support
05/2006 990-2820A *990-2820A* Customer support for this or any other APC product is available at no charge in any of the following ways: • Visit the APC Web site to access documents in the APC Knowledge Base and to submit customer support requests.– www.apc.com (Corporate Headquarters) Connect to lo...