Page 3 - DANGER; NOTICE
Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower / Rack-Mount 2U 1 Important Safety Instructions SAVE THESE INSTRUCTIONS - This manual contains important instructions that should be followed duringinstallation and maintenance of the UPS and batteries. Read the instructions carefully. Become fa...
Page 4 - Safety and General Information; Inspect the package contents upon receipt.; OFF; Electrical safety
Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower / Rack-Mount 2U 2 Safety and General Information Inspect the package contents upon receipt. Notify the carrier and dealer if there is any damage. • Adhere to all national and local electrical codes.• All wiring must be performed by a qualified e...
Page 5 - Battery safety; precautions should be observed when working on batteries:; General information; located on the chassis under the front bezel.; FCC Class A radio frequency warning; CAUTION; RISK OF HYDROGEN SULPHIDE GAS AND EXCESSIVE SMOKE
Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower / Rack-Mount 2U 3 Battery safety • The batteries typically last for two to five years. Environmental factors impact battery life. Elevated ambient temperatures, poor quality utility power, and frequent short duration discharges will shorten batt...
Page 6 - Specifications; Environmental specifications; II
Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower / Rack-Mount 2U 4 Specifications For additional specifications, refer to the APC Web site at www.apc.com. Environmental specifications SMT750RM2UC, SMT750RM2UCNC, and SMT750RMI2UCRack-Mount SMT750C and SMT750IC Tower SMT1000RM2UC, SMT1000RMI2UC,...
Page 7 - Product Overview; Displ
Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower / Rack-Mount 2U 5 Product Overview = SMT750RM2UC, SMT750RM2UCNC and SMT750RMI2UC Rack-Mount SMT750C and SMT750IC Tower SMT1000RM2UC, SMT1000RMI2UC, SMT1500RM2UC, SMT1500RM2UCNC, and SMT1500RMI2UC Rack-Mount SMT1000C and SMT1000IC Tower SMT1500C,...
Page 8 - (located on the front panel; APC By Schneider
Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower / Rack-Mount 2U 6 Front panel display features Rear panel features Online LED UPS ON / OFF key On Battery LED Error Detected LED Replace Battery LED Multi-lingual display screen UP / DOWN Selection arrows ENTER key ESCAPE key ...
Page 10 - Tower
Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower / Rack-Mount 2U 8 SMT750C Tower SMT750IC Tower SMT1000C, SMT1500C and SMT1500CNC Tower SMT1000IC and SMT1500IC Tower SMT2200C and SMT3000C Tower SMT2200IC and SMT3000IC Tower LIN K /AC T N E T WOR K su0986b su0986c LIN K /A C T NE T W O R K su09...
Page 11 - Dimensions and weights; Model
Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower / Rack-Mount 2U 9 Dimensions and weights SMT750C, SMT750IC, SMT1000C, SMT1000IC, SMT1500C, SMT1500CNC and SMT1500IC Tower Models SMT750RM2UC, SMT750RM2UCNC, SMT750RMI2UC, SMT1000RM2UC, SMT1000RMI2UC, SMT1500RM2UC, SMT1500RM2UCNC and SMT1500RMI2U...
Page 12 - Installation; Network Management card; RISK OF DAMAGE TO EQUIPMENT OR PERSONNEL
Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower / Rack-Mount 2U 10 Installation For UPS installation information, refer to the Installation Guide included with the UPS.The Installation Guide is also available on the APC by Schneider Electric Web site, www.apc.com. Network Management card For ...
Page 15 - Start up Settings; Connect and Install Management Software; Function; Language
Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower / Rack-Mount 2U 13 Start up Settings When the UPS is powered on for the first time the display interface displays the Setup Wizard to configure the start up settings. Configuration can also be performed using PowerChute™ software. Note: If the s...
Page 16 - Operation; Using the display; Menu; On Utility
Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower / Rack-Mount 2U 14 Operation Using the display These Smart-UPS models are equipped with an intuitive and configurable LCD display. This display complements the software interface as they convey similar information and either may be used to confi...
Page 17 - Advanced menus; Configuration; Configures UPS settings:; About; View UPS information:; Status; View detailed UPS information:; Control; Configure advanced UPS settings:; Logs
Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower / Rack-Mount 2U 15 Advanced menus The Advanced menus provide additional options for the UPS and are available only if the display interface is configured to use the Advanced menus. Configuration Configures UPS settings: • Language• Green Mode• L...
Page 19 - General configuration settings; Setting; Off
Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower / Rack-Mount 2U 17 Configuration General configuration settings Configuration settings may be changed at any time using the LCD interface or PowerChute software. Setting Factory Default Options Description High Transfer 120 V: 127 Vac 230 V: 253...
Page 20 - Outlet group configuration settings; Outlet Group 1; Turn On Delay
Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower / Rack-Mount 2U 18 Outlet group configuration settings The Main Outlet Group and the Controlled Outlet Group can be configured to independently turn off, turn on, shut down, and reboot connected equipment. The Main and Controlled Outlet Groups c...
Page 22 - Slave ID; Master IP Addr; IP Address; DHCP
Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower / Rack-Mount 2U 20 Modbus settings UPS IP Address settings Setting Factory Default Options Description Slave ID 1 1- 223 Sets the Modbus slave address of UPS Ser+USB Disable • Enable• Disable Enables or disables UPS Modbus protocol over serial a...
Page 23 - Network Management Card Settings; Subnet Mask
Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower / Rack-Mount 2U 21 Network Management Card Settings These settings are available only on units that have a Network Management Card (NMC) and are set in the factory.These settings can only be modified using an external interface, like the NMC web...
Page 24 - Overview; button; Normally open contacts; Secure the wires by tightening the screws.; Normally closed contacts; RISK OF ELECTRIC SHOCK
Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower / Rack-Mount 2U 22 SmartConnect SmartConnect Ethernet Port allows you to monitor the health and status of your UPS from any device connected to the Internet. Availability of features varies by terms of use. Access the terms of use at https://sma...
Page 25 - national and local regulations.; Battery Replacement; Always recycle used batteries.; UPS Model
Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower / Rack-Mount 2U 23 The EPO interface is a Safety Extra Low Voltage (SELV) circuit. Connect the EPO interface only to other SELV circuits. The EPO interface monitors circuits that have no determined voltage potential. SELV circuits are controlled...
Page 26 - Troubleshooting
Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower / Rack-Mount 2U 24 Troubleshooting Problem and Possible Cause Solution The UPS will not turn on or there is no output. The unit has not been turned on. Press the UPS ON / OFF key once to turn on the UPS. The UPS is not connected to AC power. Be ...
Page 27 - Limited Factory Warranty
Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower / Rack-Mount 2U 25 Limited Factory Warranty Schneider Electric IT Corporation (SEIT), warrants its products to be free from defects in materials and workmanship for a period of three (3) years excluding the batteries, which are warranted for two...
Page 28 - Transport the Unit; Service; specific instructions.; transit is not covered under warranty.
Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower / Rack-Mount 2U 26 Transport the Unit 1. Shut down and disconnect all connected equipment.2. Disconnect the unit from utility power.3. Disconnect all internal and external batteries (if applicable).4. Follow the shipping instructions outlined in...
Page 30 - APC by Schneider Electric; Worldwide Customer Support; Knowledge Base and to submit customer support requests.
04/2023 EN 990-5442E APC by Schneider Electric Worldwide Customer Support Customer support for this or any other APC by Schneider Electric product is available at no charge in any of the following ways: • Visit the APC by Schneider Electric web site to access documents in the APC by Schneider Electr...