Thank You! Thank you for selecting the APC SmartSlot 5 Port 10Base-T Hub (AP9615). It has been designed for many years of reliable, maintenance-free service in combination with your American Power Conversion (APC) uninterruptible power supply (UPS). APC is dedi-cated to the development of high-perfo...
Page 3 - Contents
i Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Overview 1 Features of the5 Port 10Base-T Hub 1 Hardware requirements 1 Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Front panel 2 APC Communications Compati...
Page 5 - Introduction; Overview
1 Introduction Overview The SmartSlot ™ 5-Port 10Base-T Hub is an APC accessory that allows you to expand or create a local area network (LAN) by installing it in the SmartSlot of an APC UPS or expansion chassis. Features of the 5 Port 10Base-T Hub The following list shows some of the features of th...
Page 6 - Product Description; Front panel; Communications; Compatibility; The; Communications Compatibility Number (; CCN; for your hub may be different from the; Smart Slot
2 Product Description Front panel This figure shows the front panel of the 5 Port 10Base-T Hub. The features of the front panel are described in the paragraphs that follow. Figure 1: Front Panel and Connector Detail APC Communications Compatibility Number The APC Communications Compatibility Number ...
Page 7 - continued; LEDs; provide important information concerning opera-; LEDs; Continued on next page; Label
3 Product Description continued LEDs The LEDs provide important information concerning opera- tion of the hub and each of its ports. Refer to the table below for a description of the conditions indicated by LEDs . Continued on next page Label Color Activity Description Pwr Green On The hub is receiv...
Page 8 - Station ports; Note: A Station port acts as an Uplink port when it is used; Uplink port; Communication
4 Product Description continued Station ports The Station ports are the first 4 RJ-45 ports, which are labeled 1X – 4X . The Station ports use straight-through UTP cables to connect the hub with: • Workstations or other non-hub devices that you want to include in your network. • The Uplink port of a...
Page 9 - Installing the Hub; Warning; Management Accessories on Critical Systems.; Installation
5 Installing the Hub Warning Do not operate the 5 Port 10Base-T Hub where conditions are outside the limits listed in “Product Specifications” on page 14. Installing on critical systems The installation procedure that follows may involve shut-ting off power from the UPS . However, if your setup requ...
Page 10 - Symmetra; UPS; DP
6 Installing the Hub continued Installation procedure, continued Matrix- UPS ™ a Shut down and power off the connected equipment. b Turn off the circuit breaker on the bottom left side on the back panel of the UPS . Symmetra ™ Power Array ™ a Shut down and power off the connected equipment. b Turn o...
Page 11 - Note: While it is not possible to install the hub
7 Installing the Hub continued Installation procedure, continued 3 Use a #2 Phillips head screwdriver to remove the 2 screws fastening the SmartSlot cover plate to the back panel of the UPS or triple chassis. Keep the screws for Step 5 below. Save the SmartSlot cover plate for future use (e.g. shipp...
Page 12 - power outlet
8 Installing the Hub continued Installation procedure, continued 5 Secure the hub with the screws removed in Step 3. 6 Using straight-through UTP cables, connect the Sta- tion ports ( 1X – 4X , in any order) to each worksta- tion’s 10Base-T port or to the Uplink port of a hub to be connected in casc...
Page 13 - Symmetra Power Array; Triple Chassis for Silcon DP300E Series UPSs
9 Installing the Hub continued Installation procedure, continued Symmetra Power Array a Turn on the System Enable switch on the bottom left side on the back panel of the UPS . b Turn on the UPS via the PowerView display. c Power on the connected equipment. Smart-UPS DP a Turn on the ON/OFF switch on...
Page 14 - Maximum; stations, as shown below in Figure 4. Note
10 Installing the Hub continued Maximum configuration Using a star configuration, you can cascade up to ten 5 Port 10Base-T hubs together to provide network connections for as many as 32 stations, as shown below in Figure 4. Note the use of a crossover cable to connect the Uplink ports of the 2 cent...
Page 15 - Removing the Hub; Removal
11 Removing the Hub Removal procedure To remove the 5 Port 10Base-T Hub, perform the following steps in the order given. 1 Disconnect all cables from the hub. 2 Turn off the UPS or device that houses the hub. (For detailed instructions, see “Installation procedure” on page 5.) 3 Use a #2 Phillips he...
Page 16 - Troubleshooting; Table 2 provides suggestions for troubleshooting your hub.; LED; Col
12 Troubleshooting Troubleshooting suggestions Table 2 provides suggestions for troubleshooting your hub. Continued on next page LED Action Cause Solution Col Blinking Normal data collisions on the network. No action is necessary. Col Blinking excessively Data collisions are occurring because of a h...
Page 17 - Partition
13 Troubleshooting continued Troubleshooting suggestions, continued LED Action Cause Solution Partition On 32 consecutive collisions have caused the port to partition. Check that the correct cable is in use and verify that the connected equipment is set to operate at 10 Mbit and half-duplex mode. As...
Page 18 - Specifications; Product; VDC; Physical
14 Specifications Product specifications The following table shows the product specifications for the 5 Port 10Base-T Hub. Item Specification Power Input voltage range: 18 – 30 VDC Maximum current draw: 45 mA Physical Size (H × W × D): 1.46 × 4.75 × 4.30 in(3.7 × 12.1 × 10.9 cm) Weight: 0.25 lb (0.1...
Page 19 - Warranty Information; American Power Conversion (; ) warrants the 5 Port
15 Warranty Information Limited warranty American Power Conversion ( APC ) warrants the 5 Port 10Base-T Hub to be free from defects in materials and work-manship for a period of 2 years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sol...
Page 20 - Obtaining
16 Warranty Information continued Obtaining service To obtain service for your 5 Port 10Base-T Hub, follow this procedure: 1 Note the serial number and date of purchase of the hub. (The serial number is located on the top, interior surface of the hub’s front panel.) 2 Contact APC Customer Support at...
Page 21 - Declaration of Conformity; – or –
Declaration of Conformity Application of Council Directives 89/336/EEC Standards to Which Conformity is Declared EN55022: 1995, Class BEN50082-1: 1992, including: IEC 1000-4-2: 1995 IEC 1000-4-3: 1995 IEC 1000-4-4: 1995 FCC Part 15, Class B VCCI, Class 2 Manufacturer’s Name and Address American Powe...