Page 3 - User Manual; English; SURT192XLBP External Battery Pack; For Use With Smart-UPS
990-1387A 09/2003 User Manual English SURT192XLBP External Battery Pack For Use With Smart-UPS ® RT 3000/5000/7500/10000 VA Uninterruptible Power Supply
Page 5 - Introduction; NSTALLATION; Unpacking
1 Introduction The SURT192XLBP connects to the APC Smart-UPS ® RT 3000/5000/7500/10000 VA. Together these units provide extended protection from blackouts, brownouts, sags, and surges for your computer and other critical electronic equipment. 1: I NSTALLATION Refer to the Safety Instruction sheet in...
Page 6 - Installing and Connecting the External Battery Pack(s); NOTE: The external battery packs must be installed to the; right; of the UPS when facing the; front
2 Installing the External Battery Pack(s) Your UPS model may vary from the model depicted in the diagram. The battery installation procedure is identical for all models. Prior to connecting the batteries, and tie brackets (when used), remove the feet (if installed), from the bottom of the UPS. See d...
Page 11 - Setting the UPS to Recognize the Battery Pack(s); UPS P; Business Edition
7 Setting the UPS to Recognize the Battery Pack(s) This configuration affects the accuracy of the runtime calculations that the UPS performs while running on battery power. Settings are made through supplied PowerChute® Business Edition , or PowerChute® Network Shutdown software, optional Smart Slot...
Page 12 - Network Shutdown
8 5000 VA models: Terminal Mode is a menu driven interface that enables enhanced configuration of the UPS. Connect the serial cable to the serial port on the back of the UPS. When using PowerChute ® Network Shutdown software: 1. Open a terminal program. Example: HyperTerminal • From the Desktop, go ...
Page 13 - Storage
9 2: S TORAGE , M AINTENANCE , AND S ERVICE Storage Store the UPS covered and positioned as for proper functioning, in a cool, dry location, with the batteries fully charged. Store at: 50,000 ft (15,000 m) -4 ° to 140 ° F (-20 to 60 ° C) Charge the batteries every 6 months. Replacing the Battery Mod...
Page 14 - APC; AND; Regulatory Agency Approvals
10 3: R EGULATORY I NFORMATION , C ONTACTING APC AND W ARRANTY Regulatory Agency Approvals See User Manuals for SURT3000/5000XL 3U and SURT7500/10000XL 6U models for complete regulatory approval listings. Declaration of Conformity
Page 15 - Contacting APC; In the USA ...; Limited Warranty
11 Contacting APC In the USA … Outside the USA … Refer to the APC web site, www.apc.com/support . Refer to the APC web site, www.apc.com . Select the appropriate country from the country selection field. Select the Support tab at the top of the web page. Limited Warranty American Power Conversion (A...