Page 3 - VT and XR Battery; Operation Manual; THIS DOCUMENT CONTAINS IMPORTANT SAFETY INSTRUCTIONS -
Smart-UPS® VT and XR Battery Enclosure 10-30kVA, 208V Operation Guide – 990-1599 1 Smart-UPS ® VT and XR Battery Enclosure10-30 kVA 200/208 V Operation Manual IMPORTANT! THIS DOCUMENT CONTAINS IMPORTANT SAFETY INSTRUCTIONS - PLEASE SAVE THESE INSTRUCTIONS!
Page 5 - Contents
Contents 990-2359A Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide i Safety .....................................................................1 General Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Symbols used in this guide . . . . . . . ...
Page 9 - Safety; General Safety Instructions; Symbols used in this guide
990-2359A Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 1 Safety General Safety Instructions This guide contains important instructions that should be followed when handling the UPS, Battery Enclosures, and Batteries. Symbols used in this guide Environmental symbols Gener...
Page 11 - Operation; Introduction
990-2359A Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 3 Operation Introduction Welcome to the Operation Manual covering the Smart-UPS ® VT UPS and the Extended Run Battery Enclosure (XR Battery Enclosure). This manual provides you with a detailed description of start-up...
Page 12 - The Smart-UPS VT Family Range
4 Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 990-2359A The Smart-UPS VT Family Range 352mm Enclosures 523mm Enclosures Front Rear Front view without front panel 10-15kVA Front Rear Front view without front panel 10-15kVA Front view without front panel 20-30kVA Battery ...
Page 13 - Operation Modes; Normal operation
990-2359A Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 5 Operation Modes In a stand-alone installation, the UPS has four different operating modes. If the installation includes a Maintenance Bypass Panel, bypass mode and test mode will also be available. Normal operation...
Page 14 - The Display
6 Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 990-2359A The Display Introduction The four LEDs to the left of the display indicate the operational status of the UPS. The five navigation keys to the right are used to select and open menu items, to access information, cha...
Page 15 - Navigation
990-2359A Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 7 Navigation The menu tree provides a quick overview of the user interface functions. NOTE! If you get beyond the functions described in the menu tree, do not proceed (not user functions). Press ESC to go back. Overv...
Page 16 - Basic display navigation principles; ENTER; Control functions
Operation – Navigation 8 Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 990-2359A Basic display navigation principles On the display, press ESC until you get to the Overview Screen, which provides you with basic system status information. Press UP, DOWN arrows to navigate ...
Page 17 - Status views
Operation – Navigation 990-2359A Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 9 Switch load OFF (disconnect the UPS output to the load equipment): • From the Main Menu, select Control and press ENTER • Use UP/DOWN key to navigate to Turn Load Off , and press ENTER • Sele...
Page 18 - Date
Operation – Navigation 10 Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 990-2359A Frequencies. Utility frequency, bypass frequency and output frequency in Hertz (Hz). Load and batteries. Load: Percentage of the load in relation to the total UPS capacity.Bat Voltage: shows...
Page 19 - Time
Operation – Navigation 990-2359A Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 11 Time • To change the time, press ENTER (the hour field will become active). Press the UP/DOWN arrow to select the desired time. • Follow the same procedure to change the minute and the secon...
Page 20 - Alarm threshold
Operation – Navigation 12 Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 990-2359A View Statistics (submenu under Logging). From the Logging screen on the Main Menu, you can view the statistics on operation mode changes, inverter time, duration of battery operation. • From...
Page 21 - Diagnostics screen
Operation – Navigation 990-2359A Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 13 To change the language, select Language , and press ENTER. The Language line is now active. Use the UP/DOWN arrows to select the desired language. Press ENTER to confirm your selection. Cont...
Page 23 - Display Messages/Troubleshooting; Display messages
990-2359A Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 15 Display Messages/Troubleshooting This section lists the status and alarm messages that the UPS might display. The messages are listed in alphabetical order, and a suggested corrective action is listed with each al...
Page 26 - Front Panel removal
18 Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 990-2359A Front Panel and Battery Compartment Cover Removal/Installation Front Panel removal Turn screw clockwise to unlocked position. Pull top of Front Panel free of UPS. Lift the Front Panel free of the two slots a...
Page 27 - Remove Battery Compartment Cover
Operation – Front Panel and Battery Compartment Cover Removal/ 990-2359A Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 19 Remove Battery Compartment Cover Unscrew 2 M6 screws (1 in each side of UPS). Pull top free of Enclosure. Lift Battery Compartment Cover free of...
Page 28 - Battery Compartment Cover installation
Operation – Front Panel and Battery Compartment Cover Removal/Installation 20 Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 990-2359A Battery Compartment Cover installation Place protrusions in slots at the bottom of the UPS. Place top protrusions in slots where shown...
Page 29 - Front Panel installation
Operation – Front Panel and Battery Compartment Cover Removal/ 990-2359A Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 21 Front Panel installation Insert the two protrusions at the bottom of the Front Panel into the two slots at the bottom of the Enclosure. Push the F...
Page 31 - Restart Procedure; Power application
990-2359A Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 23 Restart Procedure Power application Set the utility breaker to the ON position. If your installation includes an XR Battery Enclosure with a DC disconnect switch, set the DC disconnect switch to the ON positio...
Page 32 - Voltage confirmation
Operation – Restart Procedure 24 Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 990-2359A Voltage confirmation At the initial start-up, the display will prompt you through the following screens: • When the Confirm Voltage prompt appears on the screen, select desired voltag...
Page 33 - Mechanical Bypass; Mechanical Bypass Lever
990-2359A Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 25 Mechanical Bypass Mechanical Bypass Lever For increased availability, the UPS is equipped with an internal mechanical bypass system providing mains power directly to the output, bypassing all UPS electronics. Turn...
Page 34 - Switch into normal operation (from mechanical bypass operation)
Operation – Mechanical Bypass 26 Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 990-2359A Turn the Mechanical Bypass Lever upwards to activate the internal mechanical bypass switch. Reinstall the Front Panel. The load will now be supported directly by utility power. Sw...
Page 35 - Network Management Card replacement
990-2359A Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 27 Network Management Card with Environmental Monitor The APC Network Management Card with Environmental Monitor (AP9619) is installed in the UPS as default. It is used for remote system control and monitoring, e-mai...
Page 36 - Battery Replacement; General safety prior to module replacement
28 Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 990-2359A Battery Replacement General safety prior to module replacement Battery Module One Battery Module consists of 4 Battery Units (max. 2 Battery Modules shipped in the Enclosures). WARNING! • Only trained personnel fa...
Page 37 - Removal and installation of Battery Lock (if applicable)
Operation – Battery Replacement 990-2359A Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 29 Removal and installation of Battery Lock (if applicable) If your system is equipped with Battery Lock, follow the below procedure to remove the Battery Lock. Remove the M3 screw a...
Page 38 - Battery Module removal
Operation – Battery Replacement 30 Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 990-2359A Battery Module removal Follow the below procedures if you need to change or add a Battery Module, e.g. if you receive a display message reporting a bad battery, or if you need to ad...
Page 40 - How to Obtain Replacement Parts; Orderable parts
32 Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 990-2359A How to Obtain Replacement Parts To obtain a replacement part, contact APC Customer Support (see rear cover). 1. In the event of a Battery Module failure, the display may show additional “fault list” screens. Press...
Page 41 - Appendix; UPS Components and Options
990-2359A Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 33 Appendix UPS Components and Options 352mm Enclosures 523mm Enclosures Front Rear Front view without front panel 10-15A Front Rear Front view without front panel 10-15kVA Front view without front panel 20-30kVA Bat...
Page 42 - Serial number
Appendix – UPS Components and Options 34 Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 990-2359A Serial number The serial number is available on the type label on the rear side of the UPS. Type label 885-2540_rev01 SUVTJF10KB2F SUVTJF10KB4F SUVTJF15KB2F SUVTJF15KB4F SUVTJ...
Page 43 - System sizes, part nos., number of Battery Modules and weights
Appendix – UPS Components and Options 990-2359A Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 35 System sizes, part nos., number of Battery Modules and weights Part number coding Battery Module One Battery Module consists of 4 Battery Units (shipping in the UPS Enclosure)...
Page 44 - Stabilizing Bracket
Appendix – UPS Components and Options 36 Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 990-2359A Stabilizing Bracket Always install the Stabilizing Brackets on the 352mm Enclosure (shipped with the UPS) to enhance the stability of the Enclosure. If the Enclosure needs to ...
Page 45 - User interface
Appendix – UPS Components and Options 990-2359A Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 37 User interface Display: user-control interface used to configure the functionality, monitor the system, set alarm thresholds, and to provide audible and visual alarms. Net...
Page 46 - Foot print
Appendix – UPS Components and Options 38 Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 990-2359A Display port for the connection of display communication cable . Documentation storage. Inlet for communication cables. Battery Compartment Cover. Foot print Levelli...
Page 47 - Options; Extended Run Battery Enclosure (XR Battery Enclosure)
990-2359A Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 39 Options Extended Run Battery Enclosure (XR Battery Enclosure) XR Battery Enclosure weights 2 Battery Modules 409.5kg 6 Battery Modules 793.5kg 837mm 523mm 1490mm XR Battery Enclosure with Front Panel Battery Modul...
Page 48 - Part numbers for XR Battery Enclosures
Appendix – Options 40 Smart-UPS® VT 10-30kVA, 200/208V and XR Battery Enclosure Operation Guide 990-2359A Part numbers for XR Battery Enclosures Part number for Battery Module One Battery Module consists of 4 Battery Units. Battery Module weight 4 units = 1 Battery Module 4x23kg XR Battery Enclosure...
Page 52 - APC Worldwide Customer Support
08/2006 990-2359A *990-2359A* Customer support for this or any other APC product is available at no charge in any of the following ways: • Visit the APC Web site to access documents in the APC Knowledge Base and to submit customer support requests.– www.apc.com (Corporate Headquarters) Connect to lo...