Bosch TDL110 - Manual
Bosch TDL110 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Bosch Connected Devices and Solutions GmbH | Datasheet
Transport Data Logger | TDL110
Transparency for your Supply Chain
PART NO | 0 273 600 024
By being attached to the shipment and measuring and recording relevant parameters like temperature,
humidity, tilt, and shock, the TDL makes the delivery process of goods visible and traceable. These
measurements are then documented and visualized through a mobile application. Since the limits
of each parameter can be individually configured, any transgression of these limits is traceable and
clearly assignable to the stations throughout the entire supply chain.
MEASUREMENT PARAMETERS
Shock
Tilt
SCOPE OF DELIVERY
▶
10 devices including built-in battery
▶
Quick Start Guide
OPERATING CONDITIONS
Reference
Range
Operating temperature range -25 °C … +80 °C
Storage temperature range
0 °C … +30 °C
Humidity range
0 % rH … 100 % rH (non
condensing)
Shock / Acceleration range
max. +30°C
±13.8 g three-dimensional
ACCURACY, RESOLUTION
Reference
Accuracy
Resolution
Temperature
± 0.5 °C (0 °C ... +60 °C) / ± 1 °C (-25 °C … +80 °C)
0.5 °C
Humidity
± 5 % rH typical / ± 10 % rH maximum (20 % rH ... 80 % rH at 25 °C)
1% rH
Shock / Acceleration
± 10 %
0.1 g
TARGET MARKETS
European Union Countries: AT, BE, BG, CY, CZ, DE, DK, EE,
ES, FI, FR, GR, HR, HU, IE, IT, LT, LU, LV, MT, NL, PL, PT, RO,
SE, SI, SK
And: AR, AU, BR, CA, CN, IL, JP, KR, MY, PH, SG, TH, TR, US,
VN, ZA
Further on request