Page 2 - Owner's Manual Contents
D1265 | Owner's Manual Contents 2 Bosch Security Systems, Inc. | 9/10 | F01U169130-02 This system includes a telephone line seizure feature. The system might be programmed to communicate with a central monitoring station to report system events. You cannot use your phone while the system is communic...
Page 3 - Contents; Silencing Fire Trouble and Fire Supervisory conditions
D1265 | Owner's Manual | Contents Bosch Security Systems, Inc. | 9/10 | F01U169130-02 3 Contents Introduction..................................................................... 6 Your Keypad..................................................................... 6 Part I: Security System Basics ........
Page 4 - Working with Multiple Areas from a Single Keypad . 60
D1265 | Owner's Manual | Contents 4 Bosch Security Systems, Inc. | 9/10 | F01U169130-02 Change Time/Date (CMD + 4 + 5) ............................. 37 Door Control (CMD + 4 + 6) ....................................... 39 Description .....................................................................
Page 6 - Introduction; Your Keypad; CMD
D1265 | Owner's Manual | Introduction 6 Bosch Security Systems, Inc. | 9/10 | F01U169130-02 Introduction Your security system helps to secure life, property, and investments against fire, theft, and bodily harm. The D1265 Touchscreen Keypad is an SDI compatible device that works with GV2/GV3 Series ...
Page 7 - Part I: Security System Basics; Using the keypad; Command ENTER buttons; Points; What is a Point
D1265 | Owner's Manual | Part I: Security System Basics Bosch Security Systems, Inc. | 9/10 | F01U169130-02 7 Part I: Security System Basics Using the keypad Your security system provides quick access to functions by pressing the CMD button and one or two additional buttons. Another way to access fu...
Page 9 - Your Custom Display; The
D1265 | Owner's Manual | Part I: Security System Basics Bosch Security Systems, Inc. | 9/10 | F01U169130-02 9 Your Custom Display “At an idle state” means that the system is not currently performing a function entered by a user. There are three idle states the system might be in: Turned on (Armed)...
Page 10 - View Faulted or Bypassed Points; To Scroll Faulted or Bypassed Points; Warning Displays and Tones; Keypad Quiets for Button presses
D1265 | Owner's Manual | Part I: Security System Basics 10 Bosch Security Systems, Inc. | 9/10 | F01U169130-02 View Faulted or Bypassed Points To properly arm your system, all the exterior points (doors and windows) and interior points (motion sensors, inside doors, and so on) in the system must be ...
Page 11 - Fire Alarms; Silencing Fire Alarms
D1265 | Owner's Manual | Part I: Security System Basics Bosch Security Systems, Inc. | 9/10 | F01U169130-02 11 Fire Alarms Fire alarms are the highest priority events. When a fire point activates, your keypad emits a pulsating high-pitched fire tone. Evacuate all occupants and investigate for smoke ...
Page 12 - Burglary Alarms; Silencing Burglary Alarms; Fire Trouble and Fire Supervisory Events; Special Fire Trouble and Fire Supervisory Display
D1265 | Owner's Manual | Part I: Security System Basics 12 Bosch Security Systems, Inc. | 9/10 | F01U169130-02 Burglary Alarms Burglary alarms are the second priority. When a burglary point activates while your system is armed, your keypad emits a steady high-pitched burglary tone. The tone sounds f...
Page 13 - shows if this occurs.; Silencing an Alarm
D1265 | Owner's Manual | Part I: Security System Basics Bosch Security Systems, Inc. | 9/10 | F01U169130-02 13 Non-Fire Trouble and Supervisory Events When a trouble event occurs, your keypad might be programmed to emit three warble tones, then a pause (repeatedly). If the system was armed, the keyp...
Page 14 - How Your System Reports Alarms; Comm
D1265 | Owner's Manual | Part I: Security System Basics 14 Bosch Security Systems, Inc. | 9/10 | F01U169130-02 How Your System Reports Alarms Your security system might be programmed to automatically seize your telephones when sending reports to your security company. Once the report is completed, y...
Page 15 - Part II: System Commands; shows on the keypad.
D1265 | Owner's Manual | Part II: System Commands Bosch Security Systems, Inc. | 9/10 | F01U169130-02 15 Part II: System Commands Some of these functions might not be available in your system. Please consult your security company to determine which commands have been made available to you. If you at...
Page 17 - Ensure the display shows
D1265 | Owner's Manual | Part II: System Commands Bosch Security Systems, Inc. | 9/10 | F01U169130-02 17 Turning On the System (Arming) With a Duress Passcode Your passcode might have a special duress feature that can be your personal passcode with its last digit increased by one or two digits. Alte...
Page 20 - Master Arming all Areas
D1265 | Owner's Manual | Part II: System Commands 20 Bosch Security Systems, Inc. | 9/10 | F01U169130-02 Master Arming all Areas If you prefer, you might use the Master Arm command in the function list. Press the Menu button to access the function list configured in the keypad. 1. Ensure your keypad...
Page 26 - Using Watch Mode
D1265 | Owner's Manual | Part II: System Commands 26 Bosch Security Systems, Inc. | 9/10 | F01U169130-02 Watch Mode (CMD + 6) Description With your security system disarmed, you can use watch mode to monitor some points. Each time some points are faulted (door or window is opened) the keypad chimes ...
Page 30 - Part III: Advanced Commands; Advanced Commands; Terms Used in This Section
D1265 | Owner's Manual | Part III: Advanced Commands 30 Bosch Security Systems, Inc. | 9/10 | F01U169130-02 Part III: Advanced Commands Use this section of the manual to perform advanced system functions like add and delete user passcodes, reassign authority levels to user passcodes and operate or c...
Page 33 - Unbypass A Point; Description
D1265 | Owner's Manual | Part III: Advanced Commands Bosch Security Systems, Inc. | 9/10 | F01U169130-02 33 Unbypass A Point ( CMD + 0 + 0) Description Unbypassing a point is a way to return a bypassed point to the security system so that it can once again respond to trouble and alarm conditions. Us...
Page 41 - Access Level
D1265 | Owner's Manual | Part III: Advanced Commands Bosch Security Systems, Inc. | 9/10 | F01U169130-02 41 Access Level This function is used to manually enable/disable access authority levels assigned to users. It can also be used to temporarily disable a user’s access level instead of deleting an...
Page 45 - Table 4: Sked Table
D1265 | Owner's Manual | Part III: Advanced Commands Bosch Security Systems, Inc. | 9/10 | F01U169130-02 45 Table 4: Sked Table SKED # Except on Holiday Time Date Day of Week Function SKED 1 Yes / No S M T W T F S SKED 2 Yes / No S M T W T F S SKED 3 Yes / No S M T W T F S SKED 4 Yes / No S M T W T ...
Page 47 - Change Relay* Relay 123 is
D1265 | Owner's Manual | Part III: Advanced Commands Bosch Security Systems, Inc. | 9/10 | F01U169130-02 47 Change Relay (CMD + 5 + 4) Your security company might program relays for automatic control and/or control from your keypad of devices such as premises lighting or entry gates. Contact them fo...
Page 50 - User 3 is used here as an example.
D1265 | Owner's Manual | Part III: Advanced Commands 50 Bosch Security Systems, Inc. | 9/10 | F01U169130-02 If your system has a door access control available in the control panel, this menu allows the following User items to be changed: Passcode - Press the Passcode button to change the user’s pa...
Page 56 - ENTER
D1265 | Owner's Manual | Part III: Advanced Commands 56 Bosch Security Systems, Inc. | 9/10 | F01U169130-02 4. When the display shows ### points remain to be tested you can begin. (### is the number of points). Test each point by first activating the detection device to fault the point. If you know ...
Page 59 - Keypad Setup Menu
D1265 | Owner's Manual | Part III: Advanced Commands Bosch Security Systems, Inc. | 9/10 | F01U169130-02 59 Using Service Walk Test The Service Walk Test function is only available in the Service Menu for D9412GV3/D9412GV2 control panels. If the control panel model is D7212GV3/D7212GV2, you must ena...
Page 60 - View Area Status
D1265 | Owner's Manual | Part IV: Multi-Area Use 60 Bosch Security Systems, Inc. | 9/10 | F01U169130-02 Part IV: Multi-Area Use Working with Multiple Areas from a Single Keypad Each of the functions described in the preceding section on Advanced Commands is presented as though your system includes o...
Page 61 - View Point Status; Table 5: Screen Area Definitions
D1265 | Owner's Manual | Part IV: Multi-Area Use Bosch Security Systems, Inc. | 9/10 | F01U169130-02 61 View Point Status Use this function to identify the number or location of each point in an area, and to show the current condition of any point you select. 1. Ensure your keypad shows idle disarme...
Page 62 - Turning On the System; Turning on Selected Areas
D1265 | Owner's Manual | Part IV: Multi-Area Use 62 Bosch Security Systems, Inc. | 9/10 | F01U169130-02 Move To Area (CMD + 5 + 0) With this function you can perform tasks in an area other than the one you’re in without having to physically go to that area. Your access to other areas is limited by t...
Page 64 - Turn On the Entire System Without Delays; Turning on All or Selected Areas
D1265 | Owner's Manual | Part IV: Multi-Area Use 64 Bosch Security Systems, Inc. | 9/10 | F01U169130-02 Turn On the Entire System Without Delays You can use this function list function to turn on the entire system, both perimeter and interior, without delays. You might use this function in all of th...
Page 65 - Turning Off the System; Turning Off Multiple Areas with a Passcode
D1265 | Owner's Manual | Part IV: Multi-Area Use Bosch Security Systems, Inc. | 9/10 | F01U169130-02 65 Turning Off the System Turning Off Multiple Areas with a Passcode This function is useful for turning off multiple areas with a few button presses. It is quicker than disarming several areas indep...
Page 66 - Turning Off Selected Areas
D1265 | Owner's Manual | Part IV: Multi-Area Use 66 Bosch Security Systems, Inc. | 9/10 | F01U169130-02 Turning Off Selected Areas If your passcode has the proper authority level this function allows you to turn off areas other than the one you are in. 1. The display initially shows that the system ...
Page 67 - Appendix; User Authority Levels; If you are having trouble understanding; Passcode Worksheet; User Interface
D1265 | Owner's Manual | Appendix Bosch Security Systems, Inc. | 9/10 | F01U169130-02 67 Appendix Supplementary Information for Adding Passcodes Use the information contained in this Supplement to help you add user passcodes. User Authority Levels Your security company uses the information contained...
Page 69 - Product Handler Note
D1265 | Owner's Manual | Appendix Bosch Security Systems, Inc. | 9/10 | F01U169130-02 69 User (Passcode) Worksheet (User 000 to 038) User User Area Authority ### Passcode Group 1 2 3 4 5 6 7 8 User Name 000 1 2 3 __ __ __ 15 15 15 15 15 15 15 15 SERVICE PASSCODE 001 123456 ________ ____ 1_ __ __ __ ...
Page 84 - Security System Limitations
D1265 | Owner's Manual | Appendix 84 Bosch Security Systems, Inc. | 9/10 | F01U169130-02 User (Token) Worksheet (Blank) Master ID ###-0 Sub-User ###-1 Sub-User ###-2 Sub-User ###-3 Use r ### Site Card Data Site Card Data Site Card Data Site Card Data Security System Limitations Not even the most adv...
Page 85 - Fire Safety and Evacuation; Figure 3: Smoke Detector Locations (Elevation
D1265 | Owner's Manual | Appendix Bosch Security Systems, Inc. | 9/10 | F01U169130-02 85 Although having a security system might make you eligible for reduced insurance premiums, the system is no substitute for insurance. Warning devices cannot compensate you for loss of life or property. Fire Safet...
Page 86 - Standard Displays; Shows when you press the
D1265 | Owner's Manual | Appendix 86 Bosch Security Systems, Inc. | 9/10 | F01U169130-02 Standard Displays Your keypad uses standard and custom displays to show the status of the security system. Many standard displays are described below. Your system might not use all of them. Descriptions of your ...
Page 87 - System Trouble Displays
D1265 | Owner's Manual | Appendix Bosch Security Systems, Inc. | 9/10 | F01U169130-02 87 System Trouble Displays If you refer to any of the system trouble displays shown below, contact your security company to determine whether repairs are needed. The Silence button is only shown if a trouble tone i...
Page 89 - Security System Glossary
D1265 | Owner's Manual | Appendix Bosch Security Systems, Inc. | 9/10 | F01U169130-02 89 Security System Glossary Area A group of detection devices connected to your security system. Arm To turn on your controlled points (burglar detection devices). When an area is armed and a controlled point trips...
Page 91 - Notes
D1265 | Owner's Manual | Notes Bosch Security Systems, Inc. | 9/10 | F01U169130-02 91 Notes