Table of Contents:

  • Page 5 – Siting The Appliance
  • Page 7 – NOT; Filling Loop Detail
  • Page 11 – Installing The Appliance
  • Page 13 – – 240mm where one extension is used
  • Page 14 – INTERNAL FITTING OF THE DUCT ASSEMBLY; internal fitting of the flue.
  • Page 16 – Commissioning The Appliance
  • Page 18 – Inspection And Service
  • Page 20 – Replacement Of Parts
  • Page 21 – To set the burner pressure.; Fig. 34. Gas valve pump and air pressure
  • Page 23 – and the earth connection at the back.; Only; Conversion Instructions; Description
  • Page 24 – ational Flo
  • Page 29 – Is pump connector; ATTACH; Is capillary firmly
  • Page 31 – Ignition Check
  • Page 32 – Gas Valve Check
  • Page 34 – Component Parts List
  • Page 36 – Bosch Group
Loading the manual

Bosch Group

24i RSF

WALL MOUNTED COMBINATION BOILER FOR CENTRAL HEATING

AND MAINS FED DOMESTIC HOT WATER

INSTALLATION AND

SERVICING INSTRUCTIONS

GC NUMBERS

N.G. 47 311 37

L.P.G. 47 311 38

BOILER OUTPUT

To Domestic Hot Water – Modulated Control

Minimum 7.5 kW (25,600 Btu/h)

Maximum 23.4 kW (80,000 Btu/h)

To Central Heating – Modulated Control\

Auto Range Rated

Minimum 7.5 kW (25,600 Btu/h)

Maximum 23.4 kW (80,000 Btu/h)

THESE INSTRUCTIONS APPLY IN THE UK ONLY

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE GAS METER

This appliance must be installed by a competent person in accordance

with the Gas Safety (Installation and Use) Regulations 1994

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 5 - Siting The Appliance

4.1 The appliance may be installed in any room although particular attention is drawn to the requirements of the currentIEE Wiring Regulations BS 7671 and, in Scotland, the electricalprovisions of the Building Regulations applicable in Scotland,with respect to the installation of appliances in rooms...

Page 7 - NOT; Filling Loop Detail

See Figs. 4. 7.1 The system must comply with the requirements of BS 6798 and BS 5449. 7.2 The appliance must not be operated without the system being full of water, properly vented and pressurised. 7.3 The pressure relief valve operates at 3 bar (45lb/in 2 ). The discharge must be directed away from...

Page 11 - Installing The Appliance

Technical Helpline. The appliance is only suitable for fitting to a sealed system. 11.1 FLUE OPTIONS. The standard flue length is from 127mm to 350mm measuredfrom the appliance casing to the outer wall.Extension flue kits, a vertical take-off adapter, 45° and 90° fluebends are available to increase ...