Attenuators For 25V/70V Speaker Line
Models AT10A and AT35A

Installation and Use Manual

These 10-step plus “off” speaker attenuators allow the volume of a network of 25V or 70V speakers to be controlled from
a remote location. The AT10A attenuator can handle speaker loads of up to 10W (max.) and the AT35A attenuator can
handle speaker loads of up to 35W (max.). The AT10A fits into a single gang electrical box and the AT35A into a double
gang electrical box. Volume reduction takes place in 3 dB increments except for the 2 lowest settings, which provide 6 dB
reduction increments. A speaker “off” (“0”) position is also provided.

Attenuator Wiring

© 2005 Bogen Communications, Inc.
All rights reserved.
Specifications subject to change without notice.
54-2

1

26-0

1

A 050

1

Attenuator Settings

Speaker Installation

Red

Black Green

Hot Lead

COM

Cable Shields

Cable to speakers

Speaker “+”

positive lead

Cable from amp or zone output

Wire Nuts (4)

Note:

Cable shield is not

connected to the speaker -
the shield simply “floats.”

Speaker “-”

(negative) lead

Attenuator

STEP

ATTENUATION

10

0 dB

(Full Volume)

9

-3 dB

8

-6 dB

7

-9 dB

6

-12 dB

5

-15 dB

4

-18 dB

3

-21 dB

2

-27 dB

1

-33 dB

0

Speaker Off