Bertazzoni M93 - Manual
Bertazzoni M93 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – INSTALLER TECHNICAL MANUAL; INSTALLER INFORMATION
- Page 3 – Legs are packed in the top box.; BACKGUARD INSTALLATION INSTRUCTION; Follow the instructions below to change the oven burner nozzle:; to what is indicated in Table 1
- Page 4 – II; BURNER ADJUSTMENT; and adjust the position; Work surface burner adjustment; : follow the instructions below to adjust the minimum:; APPLIANCE ELECTRIC CONNECTION:; ground symbol
- Page 5 – TYPES OF POWER CORDS; Only gas burner
- Page 6 – USE AND MAINTENANCE MANUAL; Burner Dimension; CONTROL PANEL DESCRIPTION
- Page 7 – Tips for using burners correctly:; TABLE N°6; The oven burner can be ignited in different ways:
- Page 8 – USING THE ELECTRIC THERMOSTAT (left oven); indicates that only the oven light is turned on
- Page 10 – TABLE N°7; USING THE VENTILATED ELECTRIC OVEN (left oven); TABLE N°8
- Page 11 – USING THE CONVENTIONAL ELECTRIC GRILL; Grilling on the shelf; USING THE VENTILATED ELECTRIC GRILL; Cleaning the STAINLESS steel parts:
- Page 12 – remove burner fat if used gently.; AFTER-SALES TECHNICAL SERVICE AND SPARE PARTS; Fig. 3 Fig. 4 Fig. 5
INSTALLATION, MAINTENANCE AND USE
INSTRUCTIONS FOR
FREE-STANDING COOKERS
91,5x64
cm (type M93/M93V)Dual oven
READ THE INSTRUCTION BOOKLET BEFORE INSTALLING AND USING
THE APPLIANCE.
The manufacturer will not be responsible for any damage to property or to persons
caused by incorrect installation or improper use of the appliance.
The manufacturer is not responsible for any inaccuracies, due to printing or transcription
errors, contained in this booklet. In addition, the appearance of the figures reported is also
purely indicative.
The manufacturer reserves the right to make changes to its products when considered
necessary and useful, without affecting the essential safety and operating characteristics.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 CONTENTS: INSTALLER TECHNICAL MANUAL ............................................................................................................... pg. 2 Installing the cooker - Installation information .................................................................................................
3 ROOM VENTILATION To ensure that the appliance operate correctly, the room where it is installed must be continuously ventilated. The room volume should not be less than 25 m³ and the quantity of air needed shall be based on the regular combustion of gas and on the ventilation of the room. Natural ...
4 TABLE N°1: Adaption to various types of gas APPLIANCE CATEGORY: II 2H3+ Burner Types of Gas Pressure Nozzle Diameter Rater Capacity Reduced Capacity by-pass Diameter mbar 1/100 mm. g/h l/h kw kcal/h kw kcal/h 1/100 mm. Natural G20 20 72 - 95 1 860 0,48 413 34 reg. Auxiliary Butane G30 30 50 73 - 1...