Barco RLM W6 - Manual
Barco RLM W6 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – RLM W6 Serial Commands; Operation Commands; Midposition; Get operations command example:; Increase & Decrease operations command examples:; Set operations command example:; Execute command example:
- Page 3 – Barco RLM W6 Operation Commands; Command; contrast
- Page 4 – saturat
- Page 5 – Please refer to
- Page 9 – = Chinese Simplified
- Page 10 – signal
- Page 12 – status; errcode
- Page 13 – Applicable” in some specific conditions.; Not applicable when; picture mute is on.; election “Zoom” is not applicable when aspect ratio is set to Native.; when color space is set to custom.; Note10: Not applicable; Not applicable; when lamp is cooling.; Note13: Only MCU version number will be read back in standby mode.
- Page 14 – Main Select
RLM W6 Serial Commands
Rev. 6d
Page 1 / 14
Barco RLM W6
Serial (RS-232) Command
Protocol
Interface and Requirements
The RS-232 Commands use only ASCII characters which can be entered
using a typical terminal emulator like Windows HyperTerminal with the
following setting:
Bits per second: 38400
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
Note that each input character will be echoed on the terminal by MCU and
there is no need to set the local echo “ON” with the terminal setting.
System Operation commands
.
The Operation commands tell the projector what to do. All commands
start with 2 letters: “op” for operations commands, and a space [SP] then
following a control command then finally the value wants to read, set,
increase or decrease. All commands must end with a carriage return (ASCII
hex 0D), shown as [CR] below. The syntax for operations commands is as
follows:
op
[SP]
<operation command>
[SP]
<Setting Value>[CR]
For all but Execute functions the response from the projector will be the
command and “= <value>” where <value> is the current value or “NA” if the
value is not available. For Execute functions the response will be the same
command. All responses will be in CAPS. Please refer to the following
table for command list and examples:
System Operation command:
Operation Commands
Values
Set
= <value>
Makes the unit take that value.
Get
?
Asks what the current value is.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
RLM W6 Serial Commands Rev. 6d Page 2 / 14 Operation Commands Values Increment + Adds 1 to the current value. Decrement - Subtracts 1 from the current value. Execute (none) Performs an action such as a reset. Motor operation command: For motor control like lens shift, focus and zoom, the parameters ...
RLM W6 Serial Commands Rev. 6d Page 3 / 14 Input: op auto.img [CR] Response: OP AUTO.IMG The list of valid operation commands for Barco RLM W6 are shown in below Table. Barco RLM W6 Operation Commands Command Item Operation Commands Values Notes 1-1 input.sel = ? 0 = HDMI 1 1 = HDMI 2 2 = RGB D-15 3...
RLM W6 Serial Commands Rev. 6d Page 4 / 14 Barco RLM W6 Operation Commands Command Item Operation Commands Values Notes 2-3 saturat = ? + - 0 - 200 Note2; Note4 2-4 tint = ? + - 0 - 200 Note2; Note4 2-5 sharp = ? + - 0 - 200 Note2 2-6 nr = ? + - 0 - 200 Note2 2-7 color.temp = ? 0 = 3200K 1 = 5400K 2...