System manual MeDis 5MP1HM 3 CONTENTS Introduction ....................................................................................................... 7 Introduction ......................................................................................................... 9 Contents of the packag...
Page 7 - INTRODUCTION
Page 9 - Contents of the package; Preparations before installation
System manual MeDis 5MP1HM 9 INTRODUCTION BARCO MeDis ® 5MP1H is a total display solution for medical applications. This can be a single-head or multi-head system. MeDis comes with everything you need to set-up a complete viewing system, from video cables to displays. Contents of the package Please ...
Page 11 - DISPLAY
System manual MeDis 5MP1HM 11 DISPLAY CONTROLLER INSTALLATION
Page 13 - BarcoMed 5MP1HM Product Overview; Features of the BarcoMed 5MP1HM
System manual MeDis 5MP1HM 13 BarcoMed 5MP1HM Product Overview The BarcoMed 5MP1HM Display Controller delivers a quality 2048 x 2560 pixel image with 1024 simultaneous shades of gray for medical imaging applications. The BarcoMed 5MP1HM includes features specifically designed to meet the demands of ...
Page 15 - HARDWARE INSTALLATION; Familiarizing Yourself With the 5MP1HM; Jumper Location
System manual MeDis 5MP1HM 15 HARDWARE INSTALLATION Notice: Wear a protective ESD strap during installation or handling of the controller. Electrostatic charges can damage the controller. Familiarizing Yourself With the 5MP1HM Prior to installing your 5MP1HM controller(s) in your PC please take a fe...
Page 16 - Examples of PCI Slots
System manual MeDis 5MP1HM 16 should now remove any third party VGA controller from your system or disable the integrated VGA controller.If you decide to use a separate VGA card and monitor as your boot monitor, you must disable the on-board VGA capabilities of the BarcoMed 5MP1HM by moving the jump...
Page 17 - Installing the BarcoMed 5MP1HM Display Controller; Running Multiple BarcoMed Display Controllers in a Single
System manual MeDis 5MP1HM 17 Installing the BarcoMed 5MP1HM Display Controller Install the 5MP1HM into your computer following these steps:1. Turn off the power to your computer and disconnect the power cord. 2. Remove the chassis cover according to the manufacturers instructions. Be sure to obser...
Page 21 - DISPLAY INSTALLATION; Example
System manual MeDis 5MP1HM 21 DISPLAY INSTALLATION Example An example of a correct set-up is shown in figure 5.Please take a good look at the figures, and then read the rest of the text very carefully. #1 #2 Display #1(rear view) Display #2(rear view) Video cable #1 Video cable #2 Remote cable Remot...
Page 22 - Placing and configuring the displays; Connection of the video cables
System manual MeDis 5MP1HM 22 Placing and configuring the displays 1 The last part of this system manual is a copy of the display user manual. Follow the precautions and guidelines from this part. 2 The display(s) from the MeDis system are numbered. E.g., in a quad-head system, the displays are numb...
Page 23 - Connection of the Remote cables; Power up the system
System manual MeDis 5MP1HM 23 Connection of the Remote cables Note : One of the remote cables is packed inside the MediCal box. 1 The Remote cables that come with MeDis are not numbered. It does not matter which cable you connect to which display, as long as you take the Remote inputs and outputs on...
Page 25 - BARCOMED DRIVER
System manual MeDis 5MP1HM 25 BARCOMED DRIVER AND SOFTWARE INSTALLATION
Page 29 - Software; Using the BarcoMed Product Installation Wizard
System manual MeDis 5MP1HM 29 Installing the BarcoMed 5MP2 AURA, 5MP2, 5MP1HM, 5MP1H or 4MP2 Windows 2000 Software SPECIAL NOTE: Prior to installing the BarcoMed drivers and related software you MUST install the BarcoMed Display Controller(s), connect the high resolution display(s) to the card(s), a...
Page 31 - Driver Installation
System manual MeDis 5MP1HM 31 Figure 7 Driver Installation 7. Click Next on the Display Driver Wizards Welcome Screen to continue or Cancel to exit the Display Driver Wizard and return to the Software Install Wizard. 8. The Device Selection Screens dialog box should show only those devices phy...
Page 35 - BARCO DPMS Screen Saver Installation
System manual MeDis 5MP1HM 35 to enable DualView, you will need to reinstall the drivers with the Enable the DualView device? checkbox checked. Figure 12 BARCO DPMS Screen Saver Installation 15. Click Next on the Welcome Screen of the BARCO DPMS InstallShield Wizard to begin the installation. Cl...
Page 38 - Setting the Resolution of Your 5MP1HM
System manual MeDis 5MP1HM 38 Setting the Resolution of Your 5MP1HM 1. To set the resolution for your high resolution display(s), right click on the desktop and select Properties . Select the Settings tab (see figure 16). Now select the rectangle that represents the virtual display of the BarcoM...
Page 40 - Reinstalling or Updating your BarcoMed 5MP2 AURA, 5MP2,
System manual MeDis 5MP1HM 40 Figure 16: The Windows 2000 Display Properties Control Panel Settings Tab after the drivers have been installed and the resolution set. Note: The system shown in figure 16 above is a single BarcoMed Display Controller, no 3 rd party VGA card configuration, your system m...
Page 43 - MP1HM, 5MP1H or 4MP2 Windows XP Software
System manual MeDis 5MP1HM 43 Installing the BarcoMed 5MP2 AURA, 5MP2, 5MP1HM, 5MP1H or 4MP2 Windows XP Software SPECIAL NOTE: Prior to installing the BarcoMed drivers you MUST install the BarcoMed Display Controller(s), connect the high resolution display(s) to the controller(s), and turn the high ...
Page 51 - Setting the Resolution of Your 5MP1HM
System manual MeDis 5MP1HM 51 Setting the Resolution of Your 5MP1HM Once you have completed the installation of the display driver, you need to set the resolution for each display connected to each controller.1. To set the resolution for your high resolution display(s), right click on the desktop an...
Page 55 - BARCOMED
System manual MeDis 5MP1HM 55 BARCOMED CONTROLLER TOOLS
Page 57 - BARCOMED DRIVER TAB; Introduction
System manual MeDis 5MP1HM 57 BARCOMED DRIVER TAB Introduction After the BarcoMed Windows Display Controller Driver is installed, a new Display Properties tab is available for configuring special features of the BarcoMed Display Controller. Please note that you must have logged on to Windows using a...
Page 59 - Status; Graphics Board; Palette Mode; UserModifiable Color Palette
System manual MeDis 5MP1HM 59 Status Displays the current BarcoMed Display Controller, driver, and the currently selected display resolution. Graphics Board This displays the current BarcoMed Display Controller. Driver Version This displays the current BarcoMed driver version. Resolution This displa...
Page 60 - Static Gray Palette with NO system colors
System manual MeDis 5MP1HM 60 index 10 to 245 contain the missing gray values so that the palette has the full 256 gray values within it. Please note that dithering is not permitted while in this mode. The Enable Dithering check box will be grayed-out, and dithering will be automatically disabled re...
Page 61 - Drawing Modes; Enable DirectDraw; Monitor Configuration
System manual MeDis 5MP1HM 61 application requires this Static Gray Palette with NO System colors mode, contact your application provider. Drawing Modes You can choose one or both of the following Drawing Modes: Enable DirectDraw This option allows the user to enable or disable DirectDraw. DirectD...
Page 62 - Languages supported
System manual MeDis 5MP1HM 62 one row option from the pull-down list. This would cause the Windows virtual desktop to be resized to fit on the three monitors, and you can move your cursor horizontally from one screen to the other.If Custom Configuration is displayed, it means that the current mon...
Page 63 - BARCOMED HARDWARE TAB
System manual MeDis 5MP1HM 63 BARCOMED HARDWARE TAB Introduction The BarcoMed Hardware Tab is used for gathering information about BarcoMed Display Controller(s). For all BarcoMed Display Controller(s) it will display PCI information. In addition for BarcoMed Display Controller(s) based on the AURA ...
Page 65 - Using The BarcoMed Hardware Tab; Device
System manual MeDis 5MP1HM 65 Figure 31: BarcoMed Hardware Tab under Windows 2000 and Windows XP Using The BarcoMed Hardware Tab Device Displays the current BarcoMed Display Controller, driver, and the currently selected display resolution. Identify Device: This button is for BarcoView Medical Imagi...
Page 70 - BARCO DPMS Screen Saver Options
System manual MeDis 5MP1HM 70 BARCO DPMS Screen Saver Options From the BARCO DPMS Screen Saver Control Panel you can change many DPMS screen saver elements simultaneously. The DPMS screen saver elements in each scheme are work schedule, work day screen saver, DPMS settings after work day, and many...
Page 72 - Getting started with the BARCO DPMS
System manual MeDis 5MP1HM 72 e t a t S S M P D s g n i v a S r e w o P r o t i n o M e m i T y r e v o c e R n O e n o N A / N y b - d n a t S l a m i n i M t r o h S d n e p s u S l a i t n a t s b u S r e g n o L f f O m u m i x a M t s e g n o L Monitor Settings Select the amount of time the dis...
Page 73 - Using the BARCO DPMS Screen Saver
System manual MeDis 5MP1HM 73 privileges. If a user who does not have administrator privileges tries to save a scheme using an existing default scheme name, an error message is displayed saying you must have administrator rights to modify a default scheme. If an administrator saves a scheme using ...
Page 78 - Installing or Reinstalling BARCO DPMS
System manual MeDis 5MP1HM 78 10. Save your preferences by pressing the Save As button and entering a new profile name in the Save Profile Setting dialog box. 11. Apply your new scheme by clicking OK. 12. Click OK again to close the Display Properties Control Panel. Installing or Reinstall...
Page 81 - MEDICAL SOFTWARE
System manual MeDis 5MP1HM 81 MEDICAL SOFTWARE INSTALLATION AND USAGE
Page 83 - USING MEDICAL
System manual MeDis 5MP1HM 83 MEDICAL SOFTWARE INSTALLATION Install MediCal on the PC. Follow the instructions from the MediCal User Guide. Important: Do not forget you have to have Administrator privileges to install or uninstall MediCal. OPTICAL SENSOR CONNECTION If you are using an X-Rite DTP92 s...
Page 85 - DISPLAY USER
Page 87 - Trademark information
System manual MeDis 5MP1HM 87 © 2003 BARCO nv. All rights reserved. Trademark information TrueGrey, MediCal, BarcoMed, and MeDis are registered trademarks of BARCO NV.Windows NT is a registered trademark of Microsoft Corporation. Display User Manual
Page 88 - SAFETY INSTRUCTIONS
System manual MeDis 5MP1HM 88 Regulations This apparatus conforms to: IEC601-1, UL2601-1, cUL2601-1, EN 60601-1 This apparatus is classified as Type B without Applied Part. Usage in Hazardous locations Class I equipment Equipment not suitable for use in the presence of a flammable anaestheti...
Page 89 - Overview; Resolution and bandwidths
System manual MeDis 5MP1HM 89 INTRODUCTION Overview Resolution and bandwidths The BARCO MGD 521 M and MGD 521 MKII displays are ultra-high resolution, grayscale portrait displays. Their outstanding visual performance, combining a 5 MegaPixel resolution with a very high brightness, makes them ideal f...
Page 90 - Power saving system; Versions and options
System manual MeDis 5MP1HM 90 adjust and check BARCOs medical displays.A lot of adjustments can also be done on the monitor itself, by means of an extensive on-screen menu system, accessible from the rear panel controls. Power saving system The MGD 521 displays are equipped with a power saving syst...
Page 91 - About the manuals
System manual MeDis 5MP1HM 91 About the manuals This guide is meant for people who want to install and use the MGD 521 displays, as well as people who need to install and adjust the displays. Chapter 4, Adjustments, is meant for this second category only, because it describes actions and procedures ...
Page 92 - INSTALLATION; Precautions
System manual MeDis 5MP1HM 92 INSTALLATION Precautions Keep your original packaging. It is designed for this display and is the ideal protection during transport. Do not lift the display all by yourself to avoid injury. Avoid reflections in the picture tube to reduce eye strain. Place the disp...
Page 93 - Controls and connectors
System manual MeDis 5MP1HM 93 Controls and connectors 1 REMOTE OUT REMOTE IN VIDEO HS / CS VS 2 4 5 6 7 8 91011 3 {1} Optical sensor plug {2} Ambient Light Compensation (ALC) sensor (optional) {3} Green power LED {4} Control knob, combination of a push button and a turning knob. The control knob is ...
Page 94 - Signal connection; a) Connection of video signals
System manual MeDis 5MP1HM 94 Signal connection a) Connection of video signals The connected equipment must comply to all relevant safety demands. Important: The use of low-quality video cables can distort the video signal and influence diagnosis.1. Check the impedance of the imaging board that prod...
Page 96 - d) Connection of power; Positioning the display
System manual MeDis 5MP1HM 96 d) Connection of power 1. Power cord: Utilize a UL-listed detachable power cord, 3-wire, type SJ or equivalent, 18 AWG min., rated 300 V min., provided with a hospital-grade type plug 5-15P configuration for 120V application, or 6-15P for 240V application. 2. Plug one e...
Page 97 - Important considerations
System manual MeDis 5MP1HM 97 Important considerations The best environment for diagnostic imaging is one with controlled and dimmed ambient light. The human eye's sensitivity depends on the ambient light strength. It is most sensitive to small contrast changes (or subtle image details) at limited...
Page 98 - OPERATION: USER CONTROLS
System manual MeDis 5MP1HM 98 OPERATION: USER CONTROLS Important : The best way to adjust and control the display is by using MediCal, which displays the ideal test patterns for correct adjustment. However, in case you do not dispose of MediCal, you can control and adjust the display by means of the...
Page 99 - Contrast and brightness control; To activate the OSD; To put contrast in calibrated position
System manual MeDis 5MP1HM 99 Contrast and brightness control Contrast and brightness can be controlled through the OSD menus. To activate the OSD Turn the control knob {4} from left to right or from right to left. As a result, the OSD main menu appears. Note: The control knob should turn over at le...
Page 100 - To control contrast manually; To put brightness in calibrated position; To control brightness manually
System manual MeDis 5MP1HM 100 To control contrast manually 1 Turn the control knob to select Contrast in the OSD main menu. 2 Press the control knob shortly. The contrast control menu appears.3 In the contrast control menu, select Manual contrast adjustment and press the control knob shortly. The c...
Page 101 - Viewing Status information; To view the status information; Explanation of the Status information menu items
System manual MeDis 5MP1HM 101 STATUS INFORMATION Display Name: MGD 521MKII Serial Number: 5114147 Mode Name: New mode Mode H-frequency: 175.32 kHz Mode V-frequency: 79.94 Hz Software Version: V 1.01 Run time: 50 hours White level: 300 cd/m2 Activity timeout 30s SH compensation OFF Actual H-frequenc...
Page 102 - Other adjustments
System manual MeDis 5MP1HM 102 Software Version: The internal software version. Run time: The total operating time since production, including burn-in time. White level: The displays white level or light output after calibration, in calibrated position. Activity timeout : This is the time, expresse...
Page 103 - To change the settings
System manual MeDis 5MP1HM 103 ADVANCED SETTINGS AND ADJUSTMENTS (FOR SERVICE STAFF ONLY) Important: The functions and controls described in this chapter can have a serious impact on the performance of the display. They should be touched by trained service staff only! Settings SETTINGS INFORMATION -...
Page 104 - Explanation of the Settings menu items; Saving the settings
System manual MeDis 5MP1HM 104 Explanation of the Settings menu items LUC: LUC is short for Luminance Uniformity Control. When switched on, the internal waveform processor will modulate the gain of the video amplifier so that the luminance is equal all over the screen (within a tolerance of +/- 5%)....
Page 105 - a) How to make the adjustments; b) Description of the adjustments
System manual MeDis 5MP1HM 105 ADJUSTMENTS - Geometry - Focus - ALC - Luminance uniformity - Factory reset - Exit Adjustments menu Adjustments a) How to make the adjustments 1 Turn the control knob at the rear from left to right or from right to left to activate the On-Screen Display (OSD) main menu...
Page 109 - Advanced geometry - Corner top right
System manual MeDis 5MP1HM 109 Advanced geometry - Corner top right Advanced geometry - Corner bottom left Advanced geometry - Corner bottom right Advanced geometry - Linearity & S-correction - Horizontal linearity Advanced geometry - Linearity & S-correction - Horizontal S-corr Advanced geo...
Page 110 - Horizontal bowing left
System manual MeDis 5MP1HM 110 Advanced geometry - Advanced bowing & skewing - Horizontal bowing left Advanced geometry - Advanced bowing & skewing - Horizontal bowing right Advanced geometry - Advanced bowing & skewing - Horizontal skewing left Advanced geometry - Advanced bowing & ...
Page 112 - c) How to save changes; What happens upon saving?
System manual MeDis 5MP1HM 112 Luminance uniformity This menu allows you to calibrate the display, including the Luminance Uniformity circuit.Proceed as follows:1 Connect the X-Rite DTP92 sensor and apply the black shield (see chapter "Installation"). 2 Follow the instructions on the screen....
Page 113 - MAINTENANCE; Picture tube
System manual MeDis 5MP1HM 113 MAINTENANCE Picture tube The glass panel of the picture tube is handled with a special coating. Take care not to damage or scratch the coating.Clean the picture tube with a soft woolen or cotton cloth.The cloth should be moist, not wet!Use a watery solution or a mild c...
Page 114 - TROUBLESHOOTING; There appears no image on the picture tube, the green LED at
System manual MeDis 5MP1HM 114 TROUBLESHOOTING There appears no image on the picture tube, the green LED at the front is out Check if the power cord is properly connected to the power outlet and to the display. Check if the power button is switched on. There appears no image, the green LED is on...
Page 115 - BACKGROUND INFORMATION; Luminance Uniformity Correction
System manual MeDis 5MP1HM 115 APPENDIX A: BACKGROUND INFORMATION Luminance Uniformity Correction A characteristic (or limitation) of every picture tube (CRT) is that the luminance decreases towards the edge of the screen surface. The decrease is normally 20 to 30 %.This is caused by the shape of th...
Page 117 - TECHNICAL SPECIFICATIONS
System manual MeDis 5MP1HM 117 Picture tube: Faceplate transmission: 32% Faceplate type: ARC panel Image representation: portrait Phosphor: P45 (standard) or P104 (option for MGD 521 MKII only) Light output: (P45 phosphor) MGD 521: Calibrated: 300 Cd/m2MGD 521M: Calibrated: 400 Cd/m2Peak: 600 Cd/m2 ...