- Page 2 – IMPORTANT FOR FUTURE REFERENCE; Model Number Serial Number Date Purchased
- Page 3 – INDEX; I. INSTALLATION INSTRUCTIONS
- Page 4 – BE SURE TO CAP WHICHEVER SIDE IS NOT CONNECTED.; ACCEPTABLE CLEARANCES:; I MASSACHUSETTS; MINIMUM CLEARANCE FROM NON-COMBUSTIBLE CONSTRUCTION
- Page 6 – Wait five minutes before attempting to re-light.; ADDITIONAL INSTALLATION INSTRUCTIONS; INSTALLATION WITH CASTERS
- Page 7 – II. OPERATING INSTRUCTIONS
- Page 9 – III. TROUBLE SHOOTING GUIDE; BURNER FLAME ADJUSTMENT:; IMMEDIATELY; ONE BURNER FAILS TO LIGHT:; If the pilot is not lit
- Page 10 – If the pilot is lit, positioned correctly,; VALVE ASSEMBLY VIEWS: (; FIGURE 2 Air Mixer Cap And Pilot Burners
- Page 11 – Gas Char Broiler; BAKERS; Figure B; Burner / Accessories
- Page 12 – Figure A; Fish Grate
- Page 14 – Exploded View
- Page 16 – V. BAKERS PRIDE LIMITED WARRANTY
BAKERS PRIDE OVEN CO., INC
.
30 Pine Street
New Rochelle, NY 10801
(914) 576-0200 Phone
(914) 576-0605 Fax www.bakerspride.com
Web Address
(800)
431-2745
US & Canada
This equipment has been engineered to provide you with year round dependable service when used
according to the instructions in this manual and standard commercial kitchen practices.
P/N U6023A 3/07
INSTALLATION
AND OPERATING INSTRUCTIONS
Dante
SERIES
GAS CHAR BROILERS
Models:
XX & CH
INTENDED FOR OTHER THAN HOUSEHOLD USE
RETAIN THIS MANUAL FOR FUTURE REFERENCE
BROILER MUST BE KEPT CLEAR OF COMBUSTIBLES AT ALL TIMES
IMPORTANT INSTRUCTIONS
After the gas supply has been connected to your unit, it is extremely important to check piping for possible
leaks. To do this, use soap and water solution or solutions which are expressly made for this purpose. DO
NOT USE matches, candles, flames, or other sources of ignition since these methods are extremely
dangerous.
Post in a prominent location instructions to be followed in the event you smell gas. Obtain these instructions
from your local gas supplier.
!
!
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause
property damage, injury or death. Read the Installation, Operating and
Maintenance Instructions thoroughly before installing or servicing this equipment.
!
!
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
CERTIFIED
R
1
MANIFOLDMANIFOLDAABURNER VALVEMANIFOLDBURNERORIFICEORIFICE HOLDERBURNERORIFICEORIFICE HOLDERBURNER VALVEVALVE EXTENSION(STRAIGHT)
FIG.4 SIDE VIEW XXE SERIESFIG.1 XXE SERIES FRONT VIEWFIG.2 CHE SERIES FRONT VIEW
A- AIR MIXER CAP HOLD-DOWN SCREWVALVE HANDLEVALVE HANDLE
MANIFOLD AND VALVE ASSEMBLY VIEWS
AIR MIXER CAPA
FLAME SENSORPILOT BURNERFLAME SENSORPILOT BURNER
AIR MIXER CAPA
Bakers Pride Oven Co.30 Pine Street, New Rochelle, NY 10801Tel :(914) 576-0200 Fax: (914) 576-0605ILLUSTRATION DGW. # 1008-30 REV. 08-04-99FIG.3 SIDE VIEW CHE SERIES
VALVE EXTENSION(CURVED)MANIFOLDAIR MIXER CAPAIR MIXER CAP
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 IMPORTANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipment. For Warranty Service and/or Parts, this information is required. Model Number Serial Number Date Purchased Notes:
INDEX I. INSTALLATION INSTRUCTIONS SECTION ITEM PAGE 1 General Description 4 2 Installation 4 3 Clearances 4 4 Gas Connection 4 5 Burners 5 6 Radiants 5 7 Top Grates 6 8 Lighting 6 9 Griddle Plates 6 10 Additional Installation Requirements 6 11 Installation with Casters 6 II. OPERATING INSTRUCTIONS ...
4. GAS CONNECTION: The gas pressure regulator supplied must be installed at the gas inlet of each broiler. Each regulator is adjusted to yield a manifold pressure of 5 in. water column for natural gas or 10 in. water column for propane gas. No pressure regulator is required for propane gas in Canada...