Model PRO 9243

Installation Manual

128-4301

PRE-INSTALLATION NOTES:

This system provides a ground output (300 mA Max) to drive an external relay that can be used to illuminate the dome
light for 30 seconds whenever the system is disarmed.
This circuit will also flash the interior dome light when the alarm is triggered.
Since a relay is required, (not included), this feature can be used with both positive and negative switched dome light
circuits.

REMOTE ENTRY ILLUMINATION: (OPTIONAL RELAY REQUIRED)

As a voltage sensing system, the alarm will trigger any time an entry point that illuminates a courtesy light is opened.
The system is shipped in the voltage sensing mode, therefore, no modifications are required to make this system a voltage
sensing alarm.
As a hardwire system, the alarm will trigger any time a door, hood, trunk, etc. is opened, by wiring directly to the switches.
This means that if the courtesy light is burned out, or the courtesy light fuse is blown, the alarm will continue to protect
all points of entry. To make this system operate as a hardwire alarm, move dip switch number 4 to the off position.
NOTE: When “Passive Arming” and “Voltage Sensing” are selected, you must hardwire the driver’s door pin switch,

or passive arming will never be initiated.

This alarm can be wired to operate as a Voltage Sensing or a Hardwire system.

VOLTAGE SENSE / HARDWIRE SELECTION: DIP SWITCH # 4

This alarm can be programmed to operate as either a “PASSIVE” or “ACTIVE” arming security system.
As a “Passive” alarm, the system will automatically arm itself approximately 30 seconds after the ignition key is turned
off, one door is opened, then all vehicle doors are closed, (arming is suspended until the last door is closed). This feature
protects the vehicle in the event you forget to arm the system using the keychain transmitter. When the optional door lock
interface is installed, the doors will operate according to the position of dip switch number 2.
This system is shipped in the passive mode, therefore no modifications are required to make the system operate as a
“Passive” alarm.
As an “Active” alarm, the system can only be armed using the keychain transmitter. There will be no backup
automatic arming. To make the system operate as an “Active” alarm, move dip switch number 3 to the off position.

PASSIVE / ACTIVE ARMING SELECTION: DIP SWITCH # 3

PASSIVE / ACTIVE DOOR LOCK SELECTION: DIP SWITCH # 2

The system is shipped with this feature activated. Any time the ignition key is turned to the off position, the doors will
automatically unlock. Any time the ignition key is turned to the on position, the doors will automatically lock.
To disable the auto lock / unlock feature, move dip switch number 1 to the "off" position.

AUTO LOCK / UNLOCK: DIP SWITCH # 1

This feature will only affect the operation of the system if the passive arming feature is selected.
When active door lock is selected, the doors will only lock when the transmitter button is pressed. When the alarm is
allowed to arm passively, at the end of the 30 second arming cycle, the doors will not automatically lock. The system
is shipped in the active door lock mode, therefore, no modifications are required for this feature.
When passive door lock is selected, when the alarm is allowed to arm passively, at the end of the 30 second arming cycle,
the doors will automatically lock. To program this feature, move dip switch number 2 to the on position.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INSTALLATION OF MAJOR COMPONENTS:

128-4301 DOOR LOCK / UNLOCK OUTPUTS: This system provides both (+) & (-) pulsed door lock outputs, for direct connection to most OEM factory installed doorlock control relays. These outputs have a maximum current capability of 300 mA , therefore, external relays must be usedon switching circuits...

Page 3 - WIRING OF THE SYSTEM:; BLACK WIRE: CHASSIS GROUND

128-4301 WIRING OF THE SYSTEM: RED w/ WHITE TRACE FUSED WIRE - (VOLTAGE SENSING): + 12 VDC CONSTANT BATTERY SOURCE This wire controls the sensitivity of the voltage sensing circuit, which detects the turning on of an interior light when adoor is opened. It will also detect the switching on of parkin...

Page 5 - WIRE POSITIVE SWITCHED DOOR LOCKS; COMPLETING THE INSTALLATION:; WIRE DRESSING

3 WIRE POSITIVE SWITCHED DOOR LOCKS In this application, the red wire provides a positive pulse during disarming, or the pulsed +12 volt unlock output. Connect the red wire to the wire that provides a low current positive signal from the factory door unlock switch to the factory doorlock control rel...