Industrial Indoor/Outdoor Solar Timer

The TI044 is a heavy-duty indoor/outdoor timer designed to control the
following loads:

The TI044 is equipped with two normally-open (NO) dry contacts
identified as

Load 1

and

Load 2

for connecting two independently

operated loads:

Load 1

follows the schedule that you have programmed into the

timer when placed in automatic mode. The load can also be
activated or deactivated manually similar to the operation of a
regular switch.
A single-pole switch can be connected to the timer to control

Load 1

as in a 3-way installation. For example, the timer can be installed
outside whereas the switch can be located remotely (e.g., inside the
house).

Load 2

always follows the sunset/sunrise program; i.e., it is

activated at sunset and deactivated at sunrise. It is usually used for
night lighting.

n

Cut power at the circuit breaker to avoid electric shock.

o

Connect the power supply between

power line

and

power neutral

terminals.

p

Connect the load and its power supply in series between

Load 1 in

and

Load 1 out

or between

Load 2 in

and

Load 2 out

depending

on the application.

NOTE

: For a 3-way installation, connect a standard single-pole switch to

the

3-way

terminals of the timer as shown on the wiring diagram.

q

Apply power at the circuit breaker.

3.1

Load 1

Load 1 can operate in Manual or Automatic mode. To switch between
the two modes, press and hold the

MODE

button for 3 seconds.

Manual Mode

In Manual mode, the TI044 operates like a regular switch to control
Load 1. Briefly press the

MODE

button to activate or deactivate the

load. (If you have connected a remote switch to the timer for a 3-way
installation, the switch can also be used to activate or deactivate
Load 1.) The mode indicator (

MAN

)

and the state (

ON

or

OFF

) are

displayed.

Automatic Mode

In Automatic mode, the TI044 controls Load 1 according to the
programmed schedule (see section 6). The mode indicator (

AUTO

),

the state (

ON

or

OFF

) and the current program number are

displayed.
To temporarily override the programmed schedule, press the

MODE

button or use the remote switch (if connected). The new state
indicator will flash to show that this state is temporary. The override
remains in effect until you press the

MODE

button (or use the remote

switch) or until the beginning of the next program.

3.2

Load 2

Load 2 follows the sunset/sunrise program (regardless of the
operating mode of the timer). For example, if Load 2 is a light, the
light will turn On at sunset and turns Off at sunrise.

NOTE

: To use Load 2, you first need to enter the city coordinates and

set the date (see section 6).

n

Applications

1.

Load type

Maximum load

Examples

Resistive load

3600 W
(30 A @ 120 V)

incandescent lights

halogen lights

block heaters

Inductive load

1200 W
(10 A @ 120 V)

fluorescent lights

compact fluorescent lights (CFL)

sodium lamps

electronic ballasts

Motor

1.5 hp @ 120 V

pumps

fans

o

Installation

2.

manual or
automatic
operation

night
lighting

120 V
power
supply

Single-pole switch

(for 3-way installation)

p

Operation

3.

• Briefly press the

button to turn the
load On or Off
(applies to Load 1
only).

• Press the button for

3 seconds to switch
between Automatic
mode and Manual
mode (applies to
Load 1 only).

Mode display
(applies to Load 1 only)

On/Off display
(applies to Load 1 only)

Program number

sunset/sunrise program

400-044-001-B ENG.fm Page 1 Tuesday, January 9, 2007 8:12 AM