Aube CT240 - Manual
Aube CT240 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
The CT240 telephone controller is designed to remotely control your
home’s thermostat. It is possible to command a temperature
decrease (Unoccupied) during a prolonged absence or a temperature
increase (Comfort) before you return home.
Depending on your thermostat’s operating characteristics, it either
connects to the Aube output (for most Aube models) or to the auxil-
iary output.
When the auxiliary output is not used to control a thermostat, it can
be used to simultaneously control a load such as a water heater,
lighting, etc.
) L J X U H
Л нк Я р Ю пϫ К са нсд а тϫ
Any device connected to a telephone line must conform to the coun-
try's standards. The CT240 telephone controller meets:
• FCC68 standards for installation on the North American network.
• FDTBR21 standards for installation on the European network.
2.1 Included Parts
• One CT240 telephone controller
• One power transformer 120 V (North America) or 250 V (Europe)
• One 5 m (16 foot) telephone cable
NOTE:
If you are using an answering machine, position the answer-
ing machine switch to ON before installing the CT240.
Make sure that your answering machine answers after a minimum of
4 rings.
) L J X U H
Ќй о та нд й в ϫ И ЬЮ г д й а ϫ О тд пЮ г
) L J X U H
Пфл д Ю Ь з ϫ Д й о пЬз з Ьпд к й
n
Mount the CT240 near a telephone outlet.
NOTE:
If you plan to connect a load having more that 30 volts on the
auxiliary output, the CT240 must be installed inside a certified electri-
cal box.
o
OPTIONAL. Connect your phone (or answering machine) to the
PHONE connector of the CT240.
p
Connect one end of the telephone cable to the LINE connector of
the CT240 and the other end to the telephone outlet in your
home.
q
Connect the thermostat and load. Both outputs work simulta-
neously.
NOTE:
Refer to your thermostat’s electrical specifications (telephone
interface) for the connection requirements.
•
If your thermostat requires a 12 VDC signal to switch to Vaca-
tion setpoint, use the ABC output (FIGURE 4):
A and C terminals:
• 0 VDC in Comfort mode
• 12 VDC in Vacation mode
NOTE:
50 mA max. for parallel connection of Aube thermostats.
•
If your thermostat requires a dry contact to switch to the Vaca-
tion setpoint, use the 123 output (FIGURE 5):
• Load = terminals 2 and 3 (NC) (open = Vacation)
• Thermostat = terminals 1 and 2 (NO) (closed = Vacation)
r
When all connections have been made, connect the power
transformer to the 9 V outlet of the CT240 and the other end to
the wall electrical outlet. The power indicator light
is ON when
the circuit is powered.
) L J X U H
ϼ Ͻ ϫ СЏ Ў ϫ О д в й Ьз ϫ пк ϫ пг а ни к о пЬ п
) L J X U H
Џ нфϫ Ю к й пЬЮ пϫ пк ϫ пг а ни к о пЬ п
1 . I n tro d u c ti o n
1
Power Indicator.
Indicates the CT240 is powered on. To turn
it off, unplug the power transformer.
2
Communication Indicator.
Indicates the CT240 has
answered and is awaiting a command.
3
Ring Indicator.
This indicator flashes when the phone rings.
4
Reset.
This button can be used to reset the CT240 to its
default values. See section 3.3.
5
Manual Output Activation Button.
Can be used to manually
switch the relay status.
6
Auxiliary Output.
See section 2.
7
12 VDC Output.
See section 2.
2 . I n s tal l a ti o n
CT240 Telephone
Controller
I n s ta l l a ti o n I n s tru c ti o n s a n d U s e r M an u a l
1/2 400-240-001-A
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.