Ariston Ep 10 Ur 2 Kw - Manual

Ariston Ep 10 Ur 2 Kw

Ariston Ep 10 Ur 2 Kw Water Heater – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
Page: / 28

Table of Contents:

  • Page 6 – Access to the heater is not normally needed on a day-to-day basis, but; Please note that turning down the stop-cock will
  • Page 8 – ) The discharge pipe must be installed with a continuous fall.
  • Page 12 – Maintenance; the sacrificial
  • Page 13 – Fault finding
  • Page 14 – This is harmless and the cause is the water and not
  • Page 16 – Merloni TermoSanitari SpA; Commercial subsidiary:; MTS MAKES USE OF
  • Page 17 – Models
  • Page 28 – PART. NOTIFICATION OF CHANGES
Loading the manual
Page 1

Unvented water heater

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

About this manual

Brand
Ariston
Model
Ep 10 Ur 2 Kw
Document type
Manual
Category
Water Heater
Language(s)
English
Pages
28
Format
PDF

Summary

Page 6 - Access to the heater is not normally needed on a day-to-day basis, but; Please note that turning down the stop-cock will

Access to the heater is not normally needed on a day-to-day basis, but 300mm clearance to the front of the water heater sould be kept forservicing and maintenanceA cold water supply pressure between 1 and 5.5 bar is required (if themains pressure is above 5.5 bar a pressure reducing valve will need ...

Page 8 - ) The discharge pipe must be installed with a continuous fall.

The EP 30 R 3KW is covered under the Building Regulations and thereforeit is not possible to accommodate the expansion water within the systempipe work and consequently a set of expansion controls must be installed.Note: The discharge from relief valves must be made in a safe andconspicuous manner; ...

Page 12 - Maintenance; the sacrificial

e) COMMISSIONING - Check that all the necessary components are supplied and for those not factory fitted, that they are the type recommended by the manufacturer for the particular water heater. - Check that the water heater/components are undamaged.- Check that the discharge pipe is plumbed so that ...