APC SUA5000RMT5U - Manual

APC SUA5000RMT5U

This Installation Manual covers the hardware setup for APC Smart-UPS units across multiple voltage and power ratings, focusing on wiring components like terminal blocks, PDU panels, and AC input/output connections. The guide includes detailed instructions for securing hardware–such as terminal block placement, cable routing, and panel attachment–across various UPS models (e.g., 208/230 V systems) while ensuring compatibility with different voltage standards. It emphasizes safety protocols during hardwiring and highlights model-specific variations in wiring diagrams.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
Page: / 4

Table of Contents:

  • Page 1 – Hardware Kit Contents and Hardwiring Safety Instructions
  • Page 2 – Smart-UPS I/O Hardware Installation Procedures
  • Page 3 – Installation Guide for 2200/3000 VA Model I/O Hardware Kit
  • Page 4 – Installation of I/O Hardware Kit for 5000RM5U Models
Loading the manual
Page 1

990

-3239A

7/

2008

Inst

allation Guide Smart-UPS I/O Hardwire Kit

Safety Information - read

these instructions befo

re hardw

irin

g

the UP

S

W

ir

ing m

u

st be perfo

rmed by

qualified electrical personnel.

Adher

e to all national and loc

al el

ectrical codes when wiring this unit.

1.

Disconnect equipment connected to the UPS.

NOTE:

Model 5000RM5U has four internal batter

ies. The two front batteries must be

disconnected.

2.

Press the OFF bu

tton located

on the front of the UPS.

3.

Disconnect batteries from the UPS.

a.

Model 5000RM5U has four internal battery mo

dules. The two front inte

rnal batteries must

be disconnected.

b.

Models 2200/3000XL require the disconnect of

one internal battery module. The XL

models may have external batteries connected

to the UPS. The external batteries must be

disconnected from the UPS.

c.

All other units require the disconn

ect of one internal battery module.

4.

Disconnect the UPS from utility power

.

When r

emoving the panels fr

om the UPS,

note which cable is connected to the AC

input. Ther

e ar

e two 4-pin connectors on

the UPS and they ar

e

not inter

changeable.

APC W

o

rldwide Customer Support

Customer support for this

or any other APC product is

available at no char

ge

in any of the following

ways:

R

ef

er to the APC W

eb s

ite

to

access

documents

in the APC K

nowledge Base and to submit

customer support requests.

www

.apc.com

(Corporate Headquarters)

Connect to localized APC W

eb sites for sp

ecific countries, each of which provides

customer support information.

www

.apc.com/support/

Global support searching APC Know

ledge Base and using e-support.

C

ontact an APC Customer Suppor

t center by telephone or e-mail.

Local, country-specific centers: go to

www

.apc.com/support/contact

for i

nformat

ion.

Contact the APC representative or other distri

butor from whom you purchased your APC product

for information on how to obtain local customer support.

E

ntir

e

con

tents copy

rig

ht 200

8

American Power Co

nver

sion

Co

rp

or

ation.

All r

ights r

eserv

ed

.

Rep

ro

duction

in

wh

ole

or

in par

t with

out per

m

issio

n is pr

ohib

ited

.

APC,

the

APC logo,

and

Sma

rt-U

PS ar

e tr

ade

m

ar

ks

of

Am

eric

an

Pow

er C

on

ver

si

on

C

orp

or

atio

n.

All other

trademarks, product

na

mes,

and

cor

pora

te names ar

e the

pr

op

er

ty of

their r

espective owner

s

an

d ar

e used f

or

in

fo

rm

ati

on

al pu

rp

os

es

on

ly

.

Terminal block

Terminal b

lock label

Screws for securing te

rmin

al block to UP

S

Model 2200/3000 Tower 100/120/230 V

Input and outpu

t panels

Blank panel to cover terminal block

Model 2200/3000XL

120

/208/230

V

Input panel

Output panel

Blank panel to cover terminal block

Model 5000RM5U 208/230 V

Input and output panels

Bla

nk pan

el to cover terminal block

2 wire nuts

8 screws for securing

pan

els to UP

S

4 grounding screws

Pa

cka

ge Conte

n

ts

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

About this manual

Brand
APC
Model
SUA5000RMT5U
Document type
Manual
Language(s)
English
Pages
4
File size
1.3 MB
Format
PDF

Summary

Page 1 - Hardware Kit Contents and Hardwiring Safety Instructions

Details regarding hardware kit contents, including terminal blocks, screws, and blank panels, along with safety instructions for hardwiring the UPS.

Page 2 - Smart-UPS I/O Hardware Installation Procedures

Step-by-step instructions and diagrams for installing and wiring the Smart-UPS I/O Hardware Kit, securing terminal blocks, and attaching hardware panels; notes on model variation exist.

Page 3 - Installation Guide for 2200/3000 VA Model I/O Hardware Kit

Instructions detailing the installation procedure for the Smart-UPS I/O Hardware Kit, focusing on securing the PDU panel, connecting input/output cables, and attaching terminal blocks for 2200/3000 VA models.