Page 3 - Contents
Contents Switched Rack PDU Installation and Quick Start i Product Description and Inventory . . . . . . . . . . . . . . . . . . . . . . 1 AP7902 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 AP7911 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 5 - Product Description and Inventory
Switched Rack PDU Installation and Quick Start 1 Product Description and Inventory AP7902 and AP7911 are Switched Rack Power Distribution Units (Rack PDUs) that distribute power to devices in the rack. The user can turn on, turn off, or recycle power back to the individually controlled outlets. The ...
Page 6 - User’s Guide; Inventory; Quantity
Product Description and Inventory 2 Switched Rack PDU Installation and Quick Start Additional documentation The Rack PDU User’s Guide and the Rack PDU Addendum are available on the supplied CD and on the APC Web site: www.apc.com . The User’s Guide (.\doc\eng\usrguide.pdf) contains additional inform...
Page 7 - How to Install the Rack PDU; Installation guidelines
Switched Rack PDU Installation and Quick Start 3 How to Install the Rack PDU Installation guidelines • For a Rack PDU installed in an enclosed communications rack, the recommended maximum ambient temperature is 45° C (113º F). • Install the Rack PDU so that it does not reduce the air flow required f...
Page 8 - Attach cords to the tray; or any other standard
How to Install the Rack PDU 4 Switched Rack PDU Installation and Quick Start Attach cords to the tray Attach a cord to the tray by looping the cord and securing it to the tray, using a wire tie (provided). Cords from both banks of outlets may be secured to the bottom tray, or you may attach an addit...
Page 9 - For a recessed placement
How to Install the Rack PDU Switched Rack PDU Installation and Quick Start 5 For a recessed placement : use four flat-head screws (provided) through the last four holes of each bracket. 2. Insert caged nuts (provided with the rack) on the vertical mounting rails above a number at the start of two U-...
Page 10 - Operation; Display interface; Am; Amps; Switched Rack PDU
6 Switched Rack PDU Installation and Quick Start Operation Display interface Link - Rx/Tx 10 /100 Status Serial Port Reset - Warning - OK - Overload B2 B1 TOTAL Am ps Amps Amps Switched Rack PDU Line Indicator LED: Indicates normal (green), warning (yellow), and alarm (red) conditions for bank 1 (B1...
Page 11 - Quick Configuration; Overview
Switched Rack PDU Installation and Quick Start 7 Quick Configuration Overview You must configure the following TCP/IP settings before the Rack PDU can operate on a network: • IP address of the Rack PDU • Subnet mask• Default gateway TCP/IP configuration methods Use one of the following methods to de...
Page 12 - Utility
Quick Configuration 8 Switched Rack PDU Installation and Quick Start APC Management Card Wizard You can use the APC Management Card Wizard at a Windows ® 98, Windows NT ® 4.0, Windows 2000, or Windows XP computer to configure a Rack PDU. 1. Insert the APC Switched Rack PDU Utility CD into a computer...
Page 13 - You can use an RFC951-compliant BOOTP server to configure; BOOT Mode; causes it to discover the BOOTP server.; apc; Addendum
Quick Configuration Switched Rack PDU Installation and Quick Start 9 BOOTP. You can use an RFC951-compliant BOOTP server to configure the TCP/IP settings for the Rack PDU. If the BOOTP server is properly configured, the Rack PDU’s default setting ( DHCP & BOOTP ) for BOOT Mode causes it to disco...
Page 14 - DHCP Cookie Is
Quick Configuration 10 Switched Rack PDU Installation and Quick Start DHCP. You can use a RFC2131/RFC2132-compliant DHCP server to configure the TCP/IP settings for the Rack PDU. 1. The Rack PDU sends a DHCP request that uses the following to identify itself:– Vendor Class Identifier (APC by default...
Page 15 - User Name
Quick Configuration Switched Rack PDU Installation and Quick Start 11 Local access to the control console You can use a local computer to connect to the Rack PDU to access the control console. 1. Select a serial port at the local computer, and disable any service which uses that port. 2. Use the con...
Page 16 - Control console
Quick Configuration 12 Switched Rack PDU Installation and Quick Start 3. Use Telnet to access the Rack PDU at its newly assigned IP address. For example: telnet 156.205.14.141 4. Use apc for both user name and password. 5. See “Control console” on this page to finish the configuration. Control conso...
Page 17 - How to Access a Configured Rack PDU; User’s; Network
Switched Rack PDU Installation and Quick Start 13 How to Access a Configured Rack PDU Overview After the Rack PDU is running on your network, you can use the interfaces summarized here to access the unit. Web interface As your browser, you can use Microsoft ® Internet Explorer 5.0 (and higher) or Ne...
Page 18 - Telnet for basic access.; address; SNMP
How to Access a Configured Rack PDU 14 Switched Rack PDU Installation and Quick Start Telnet/SSH You can access the control console through Telnet or Secure SHell (SSH), depending on which is enabled. An Administrator can enable these access methods through the Telnet/SSH option of the Network menu....
Page 20 - How to Recover From a Lost Password
16 Switched Rack PDU Installation and Quick Start How to Recover From a Lost Password You can use a local computer, a computer that connects to the Rack PDU or other device through the serial port to access the control console. 1. Select a serial port at the local computer, and disable any service t...
Page 21 - How to Download Firmware Updates
Switched Rack PDU Installation and Quick Start 17 How to Download Firmware Updates You can use a local computer that connects to the Rack PDU through the serial port on the front of the unit. 1. Select a serial port at the local computer, and disable any service that uses that port. 2. Use the confi...
Page 22 - Specifications; Electrical
18 Switched Rack PDU Installation and Quick Start Specifications AP7902/AP7911 Electrical AP7902 AP7911 Nominal input voltage 120 V 208 V Acceptable input voltage ± 10% Nominal input voltage Maximum input current 24 A Input frequency 47 – 63 Hz Cord length 12 ft Input connectors NEMA L5-30 plug NEMA...
Page 23 - Warranty and Service; Limited warranty; Except as provided herein,; makes no warranties, express or; Obtaining service
Switched Rack PDU Installation and Quick Start 19 Warranty and Service Limited warranty APC warrants the Rack PDU to be free from defects in materials and workmanship for a period of two years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its ...
Page 24 - General policy; • In life-support applications where failure or malfunction of the
20 Switched Rack PDU Installation and Quick Start Life-Support Policy General policy American Power Conversion (APC) does not recommend the use of any of its products in the following situations: • In life-support applications where failure or malfunction of the APC product can be reasonably expecte...
Page 25 - Radio Frequency Interference; USA — FCC; This Class A digital apparatus complies with Canadian ICES-003.; Japan — VCCI; この装置は、情報処理装置等電波障害自主規制協議会(; VCCI; の基準に基づくクラス
Radio Frequency Interference USA — FCC This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a co...
Page 26 - APC Worldwide Customer Support; • Contact an APC Customer Support center by telephone or e-mail.; product for
*990-1664* APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways: • Visit the APC Web site to find answers to frequently asked questions (FAQs), to access documents in the APC Knowledge Base, and to submit customer su...