Amtrol HM-41Z - Manual

Amtrol HM-41Z

Amtrol HM-41Z – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – IMPORTANT STEPS AND DECISIONS REQUIRED BEFORE INSTALLATION
  • Page 3 – Required Components And
  • Page 4 – Plumbing; DOMESTIC WATER PIPING
  • Page 5 – Wiring
  • Page 6 – Oil Burner Controls
  • Page 7 – Control Setup & Adjustment
  • Page 8 – Mechanical Aquastat Wiring Diagrams; Boiler Controls
  • Page 10 – General Safety Information
  • Page 11 – REPLACEMENT PARTS
Loading the manual

IMPORTANT GENERAL SAFETY INFORMATION - ADDITIONAL SPECIFIC SAFETY ALERTS APPEAR IN THE

FOLLOWING INSTRUCTIONS.

DO NOT LIFT OR CARRY WATER HEATER BY THE TOP COVER. WATER HEATER DAMAGE OR PERSONAL

INJURY MAY OCCUR IF THE COVER BECOMES DETACHED.
READ CAREFULLY THE PRODUCT INSTALLATION, OPERATING AND MAINTENANCE MANUAL. FAILURE

TO FOLLOW THE INSTRUCTIONS AND WARNINGS IN THE MANUAL MAY RESULT IN SERIOUS OR FATAL

INJURY AND/OR PROPERTY DAMAGE, AND WILL VOID THE PRODUCT WARRANTY. THIS PRODUCT MUST BE INSTALLED

BY A QUALIFIED PROFESSIONAL. FOLLOW ALL APPLICABLE LOCAL AND STATE CODES AND REGULATIONS. IN THE

ABSENCE OF SUCH CODES, FOLLOW THE CURRENT EDITIONS OF THE NATIONAL PLUMBING CODE AND NATIONAL

ELECTRIC CODE, AS APPLICABLE.

THIS IS THE SAFETY ALERT SYMBOL. IT IS USED TO ALERT YOU TO POTENTIAL PERSONAL INJURY AND OTHER

HAZARDS. OBEY ALL SAFETY MESSAGES THAT FOLLOW THIS SYMBOL TO REDUCE THE RISK OF PERSONAL

INJURY AS WELL AS PROPERTY DAMAGE.

The heat transfer medium must be water or other nontoxic fluid having a toxicity rating or class of 1, as

listed in Clinical Toxicology of Commercial Products, 5th edition. The pressure of the heat transfer

medium must be limited to 30 PSIG by an approved safety or relief valve.

9040-694 (10/11)

1400 Division Road, West Warwick, RI 02893 T: 401.884.6300 F: 401.885.2567 www.amtrol.com

PLEASE READ THE FOLLOWING INSTRUCTIONS CAREFULLY

INSTALLER: LEAVE THIS MANUAL WITH THE OWNER

Models Covered:

HM-41Z & HM-80Z (Mechanical Control)

HM-41L & HM-80L (Ener-G-NET™ Digital Control)

INSTALLATION & OPERATION INSTRUCTIONS

HYDROMAX

INDIRECT-FIRED WATER HEATERS

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - IMPORTANT STEPS AND DECISIONS REQUIRED BEFORE INSTALLATION

❑ THIS PRODUCT MUST BE INSTALLED AND MAINTAINED BY A LICENSED PROFESSIONAL PLUMBER, ELECTRICIAN, AS APPLICABLE. IN ADDITION TO THE INSTRUCTIONS IN THIS MANUAL, FOLLOW ALL APPLICABLE LOCAL AND STATE CODES INCLUDING MA CMR 248 OR IN THE ABSENCE OF SUCH CODES, THE CURRENT EDITIONS OF THE NATIONAL PLUMB...

Page 3 - Required Components And

-3- If a steel hydropneumatic tank is in place, replace it with a properly sized diaphragm expansion tank. Otherwise, significant heat transfer problems can occur by causing air to be trapped in the heat exchanger. If the boiler system has an existing expansion tank and the boiler temperatures are b...

Page 4 - Plumbing; DOMESTIC WATER PIPING

-4- 4. HYDROMAX ™ Plumbing DOMESTIC WATER PIPING 1. Connect the cold water supply to the pipe labeled COLD WATER. 2. Connect the HOT WATER piping to the domestic hot water system. 3. When all domestic water piping is complete, open the cold water supply and allow some water to enter the tank. Look a...