Page 2 - D a n G e r
i Delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Safety Procedures and Precautions . . . . . . . . . . . . . 2 Installation Common Specifications . . . . . . . . . . . . . . . . . . . 3Accessori...
Page 3 - D e l I V e r y; c a U t I o n; TO PREVENT PERSONAL INJURY,
A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 1 D e l I V e r y This Alto-Shaam appliance has been thoroughly tested and inspected to ensure only the highest quality unit is provided. Upon receipt, check for any possible shipping damage and report it at once to the deli...
Page 4 - This appliance is intended to cook, hold; n o t e
A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 2 c a U t I o n Used to indicate the presence of a hazard that can or will cause minor personal injury, property damage, or a potential unsafe practice if the warning included with this symbol is ignored. c a U t I o n Used ...
Page 5 - I n s t a l l a t I o n; c o m m o n s p e c I f I c a t I o n s; a c c e s s o r I e s U s a b l e s p a c e ( l x W x D )
A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 3 I n s t a l l a t I o n A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 3 c o m m o n s p e c I f I c a t I o n s a c c e s s o r I e s A R - 6 G Overall height 78-1/8" 1983mm Overall width ...
Page 6 - t e c h n I c a l s p e c I f I c a t I o n s; D I m e n s I o n s
A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 4 I n s t a l l a t I o n A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 4 t e c h n I c a l s p e c I f I c a t I o n s 78-7/8" (2003mm) 8-7/16" (213mm) 18-3/16" (461mm) 54-5/8" ...
Page 7 - Note dimensions required for doorways and; in an upright and level position only. Do not; s I t e I n s t a l l a t I o n; t e c h n I c a l c o m p o n e n t s
A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 5 I n s t a l l a t I o n A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 5 N O T E : Note dimensions required for doorways and aisles for access of the appliance and pallet to the installation si...
Page 8 - mInImUm clearance reQUIrements
A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 6 I n s t a l l a t I o n A N S I / N S F 4 A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 6 s I t e I n s t a l l a t I o n VentIlatIon reQUIrements A ventilation hood is mandatory for the opera...
Page 9 - posItIonInG reQUIrements; NOTE: If adequate service clearance is not provided,
A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 7 I n s t a l l a t I o n A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 7 posItIonInG reQUIrements q In order to ensure proper ventilation, a minimum distance of at least 18" (457mm) must be...
Page 10 - V e n t I l a t I o n I n s t r U c t I o n s; ACCORDANCE WITH NFPA 54 COMMONWEALTH
A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 8 I n s t a l l a t I o n A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 8 V e n t I l a t I o n I n s t r U c t I o n s An adequate ventilation system is required for commercial cooking equipmen...
Page 11 - e l e c t r I c a l; e l e c t r I c a l
A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 9 I n s t a l l a t I o n A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 9 e l e c t r I c a l An electrical wiring diagram is located under the access panel beneath the drip tray of the applianc...
Page 12 - a I r s U p p l y; o p t I o n a l c o n V e r s I o n K I t s
A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 1 0 I n s t a l l a t I o n A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 1 0 a I r s U p p l y aIr sUpply Installation of this appliance must include a provision for an adequate flow of fresh a...
Page 13 - G a s c o n n e c t I o n s; NATURAL GAS PROPANE GAS; InstallatIon reQUIrements; NOTE: If a flexible gas line is used, it must be AGA; Gas pressUre chart; Natural Gas
A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 1 1 I n s t a l l a t I o n A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 1 1 G a s c o n n e c t I o n s This gas appliance has been set to operate with either natural gas or propane as indicat...
Page 14 - Gas IntaKe
A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 1 2 I n s t a l l a t I o n A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 1 2 G a s c o n n e c t I o n s The installation of this appliance must be completed by a qualified installer familiar w...
Page 15 - GAS PIPING MUST NEVER BE INSTALLED TO RUN; W a r n I n G; s e c U r I n G e l e c t r I c a l a c c e s s c o V e r
A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 1 3 I n s t a l l a t I o n A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 1 3 G a s c o n n e c t I o n s The minimum size of the gas piping or flexible connector is 3/4" (19mm). For long ru...
Page 16 - G a s e x h a U s t; neVer Use an open; • If unable to contact your gas supplier,
A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 1 4 I n s t a l l a t I o n A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 1 4 G a s e x h a U s t The appliance is not to be directly connected to a chimney vent system nor directly connected to...
Page 17 - o p e r a t I n G I n s t r U c t I o n s; b U r n e r l I G h t I n G I n s t r U c t I o n s; Verify that the manual gas shut-off valve at the; recommenDeD lIGhtInG seQUence
o p e r a t I n G I n s t r U c t I o n s A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 1 5 A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 1 5 b U r n e r l I G h t I n G I n s t r U c t I o n s Verify appliance connection to the correct gas...
Page 18 - to lIGht the bUrners:; c o n t r o l s; FLAME HEIGHT is used to activate burner ignition; n a t u r a l; D o o r c a t c h
o p e r a t I n G I n s t r U c t I o n s A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 1 6 A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 1 6 to lIGht the bUrners: 1. Select corresponding gas valve knob. Rotate the knob to the ignite positi...
Page 19 - p l a c e m e n t & a D J U s t m e n t o f s p I t s; USING A FROZEN PRODUCT IS NOT RECOMMENDED.
o p e r a t I n G I n s t r U c t I o n s A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 1 7 A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 1 7 p l a c e m e n t & a D J U s t m e n t o f s p I t s To place the spit into the appliance ins...
Page 20 - s K e W e r p r e p a r a t I o n & l o a D I n G; aDDItIonal proDUct
o p e r a t I n G I n s t r U c t I o n s A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 1 8 A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 1 8 43 " (1092mm) 37 " (940mm) 2-3 " (51mm - 76mm) 2-3 " (51mm - 76mm) s K e W e r p r...
Page 21 - c a r e a n D c l e a n I n G; e Q U I p m e n t c a r e; seVere DamaGe or; WARRANTY BECOMES VOID IF
c a r e a n D c l e a n I n G A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 1 9 A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 1 9 1. Turn the burners OFF, disconnect unit from power source and allow the appliance to cool. 2. Using hand prot...
Page 22 - m a I n t e n a n c e; c h a n G I n G o f l I G h t b U l b s; c l e a n I n G & r e s e a s o n I n G c a s t I r o n t I l e s
c a r e a n D c l e a n I n G A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 2 0 A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 2 0 m a I n t e n a n c e c h a n G I n G o f l I G h t b U l b s Prior to opening the various sections, disconnec...
Page 23 - s e r V I c e; t r o U b l e s h o o t I n G G U I D e; Defect obserVeD
s e r V I c e A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 2 1 A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 2 1 t r o U b l e s h o o t I n G G U I D e Defect obserVeD possIble caUse remeDy electrIcal Spits and lamps do not work No power ...
Page 24 - f U l l a s s e m b l y - f r o n t V I e W
s e r V I c e A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 2 2 P a r t n u m b e r s a n d d r a w i n g s a r e s u b j e c t t o c h a n g e w i t h o u t n o t i c e . A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 2 2 f U l l a s s e m ...
Page 25 - f I n a l f l o o r a s s e m b l y - f r o n t V I e W
s e r V I c e A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 2 3 P a r t n u m b e r s a n d d r a w i n g s a r e s u b j e c t t o c h a n g e w i t h o u t n o t i c e . A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 2 3 f I n a l f l o o ...
Page 26 - f I n a l f l o o r a s s e m b l y - f r o n t & b a c K V I e W
s e r V I c e A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 2 4 P a r t n u m b e r s a n d d r a w i n g s a r e s u b j e c t t o c h a n g e w i t h o u t n o t i c e . A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 2 4 f I n a l f l o o ...
Page 27 - m o t o r m o U n t a s s e m b l y
s e r V I c e A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 2 5 P a r t n u m b e r s a n d d r a w i n g s a r e s u b j e c t t o c h a n g e w i t h o u t n o t i c e . A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 2 5 m o t o r m o U n ...
Page 28 - t o p a s s e m b l y
s e r V I c e A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 2 6 P a r t n u m b e r s a n d d r a w i n g s a r e s u b j e c t t o c h a n g e w i t h o u t n o t i c e . A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 2 6 t o p a s s e m b ...
Page 29 - b o t t o m a s s e m b l y
s e r V I c e A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 2 7 P a r t n u m b e r s a n d d r a w i n g s a r e s u b j e c t t o c h a n g e w i t h o u t n o t i c e . A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 2 7 7 8 1 3 10 6 2 4 9...
Page 30 - G a s p l U m b I n G a s s e m b l y
s e r V I c e A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 2 8 P a r t n u m b e r s a n d d r a w i n g s a r e s u b j e c t t o c h a n g e w i t h o u t n o t i c e . A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 2 8 G a s p l U m b I ...
Page 31 - b U l b r e p l a c e m e n t I n s t r U c t I o n s; to replace caVIty bUlbs:
s e r V I c e A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 2 9 P a r t n u m b e r s a n d d r a w i n g s a r e s u b j e c t t o c h a n g e w i t h o u t n o t i c e . A R - 6 G R o t i s s e r i e O p e r a t i o n & C a r e M a n u a l • 2 9 a Remove the four ...
Page 34 - T R A N S P O R T A T I O N D A M A G E a n d C L A I M S; L I M I T E D W A R R A N T Y
T R A N S P O R T A T I O N D A M A G E a n d C L A I M S All Alto-Shaam equipment is sold F.O.B. shipping point, and when accepted by the carrier, such shipments become the property of the consignee. Should damage occur in shipment, it is a matter between the carrier and the consignee. In such case...