Air King ESZ368ADA - User Manual

Air King ESZ368ADA

Air King ESZ368ADA Range Hood – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – INSTALLATION INSTRUCTIONS; SECTION 1; SECTION 2; SECTION 3; SECTION 4; Figure 2; Horizontal
  • Page 3 – SECTION 5; Figure 6; Keyhole; SECTION 6; Tab; Figure 5; Damper; Figure 7
  • Page 4 – Troubleshooting Guide; Trouble; SECTION 9; Figure 9
  • Page 5 – LIMITED WARRANTY
  • Page 6 – REPLACEMENT PARTS DIAGRAM
  • Page 7 – CONSERVER CES INSTRUCTIONS; Hotte de cuisinière; Séries ESZ ADA; LIRE ET CONSERVER CES INSTRUCTIONS; CONSERVER CES INSTRUCTIONS POUR RÉFÉRENCES FUTURES.; INSTRUCTIONS GÉNÉRALES DE SÉCURITÉ; choc électrique et de blessures corporelles, incluant ce qui suit:
  • Page 8 – INSTRUCTIONS D’INSTALLATION; Figure 3
  • Page 9 – SECTION 7
  • Page 10 – Guide de dépannage; SECTION 8
  • Page 11 – GARANTIE LIMITÉE; SERVICE À LA CLIENTÈLE :
  • Page 12 – DIAGRAMME DES PIÈCES DE REMPLACEMENT
Loading the manual

IMPORTANT INSTRUCTIONS -

OPERATING MANUAL

SAVE THESE INSTRUCTIONS

www.airkinglimited.com

6728046 Rev. G 11-16

1 of 12

Range Hood

ESZ ADA Series

WARNING:

TO REDUCE THE RISK OF FIRE,

ELECTRIC SHOCK AND INJURY TO PERSON, OBSERVE THE

FOLLOWING:

a) Use this unit only in the manner intended by the manufacturer.If you have questions,

contact the manufacturer.

b) Before servicing or cleaning the unit, switch power off at service panel and lock the

service disconnecting means to prevent power from being switched on accidentally.

When the service disconnecting means cannot be locked, securely fasten a prominent

warning device, such as a tag, to the service panel.

WARNING:

TO REDUCE THE RISK OF FIRE,

ELECTRIC SHOCK AND INJURY TO PERSON, OBSERVE THE

FOLLOWING:

a) Installation work and electrical wiring must be done by qualified person(s) in accordance

with all applicable codes and standards, including fire-related construction.

b) Sufficient air is needed for proper combustion and exhausting of gases through the

flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating

equipment manufacturer’s guideline and safety standards such as those published by

the National Fire Protection Association (NFPA) and the American Society for Heating,

Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local code authorities.

c) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other

hidden utilities.

CAUTION:

FOR GENERAL VENTILATING USE ONLY. DO NOT

USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.

CAUTION:

TO REDUCE THE RISK OF FIRE AND TO

PROPERLY EXHAUST AIR, BE SURE TO DUCT AIR OUTSIDE - DO NOT

VENT EXHAUST AIR INTO SPACES WITHIN WALLS OR CEILINGS OR INTO ATTICS, CRAWL

SPACES, OR GARAGES.

d) Ducted fans must always be vented to the outdoors.

e) This unit must be grounded.

f) To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall

spray, construction dust, etc. off power unit.

g) Read all instructions before installing or using range hood.

WARNING:

TO REDUCE THE RISK OF FIRE, ELECTRIC

SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE SPEED

CONTROL DEVICE.

WARNING:

TO REDUCE THE RISK OF A RANGE TOP

GREASE FIRE:

a) Never leave surface units unattended at high settings. Boil overs cause smoking

and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

b) Always turn hood ON when cooking at high heat or when flambéing food (ie. Crepes

Suzette, Cherries Jubilee, Peppercorn Beef Flambé).

c) Clean ventilating fans frequently. Grease should not be allowed to accumulate on

fan filter.

d) Use proper pan size. Always use cookware appropriate for the size of the surface

element.

WARNING:

TO REDUCE THE RISK OF INJURY TO PERSONS

IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE

FOLLOWING:

a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off

burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately,

EVACUATE AND CALL THE FIRE DEPARTMENT.

b) NEVER PICK UP A FLAMING PAN - You may be burned.

c) DO NOT USE WATER, including wet dishcloths or towels -

a violent steam explosion will result.

d) Use an extinguisher ONLY if:

I.

You know you have a Class ABC extinguisher, and you already know how to

operate it.

II.

The fire is small and contained in the area where it started.

III.

The fire department is being called.

IV.

You can fight the fire with your back to an exit.

WARNING:

TO REDUCE THE RISK OF FIRE, USE ONLY

METAL DUCTWORK.

WARNING:

THE DUCTING FROM THIS FAN TO THE OUTSIDE OF

THE BUILDING HAS A STRONG EFFECT ON THE AIR FLOW, NOISE AND ENERGY

USE OF THE FAN. USE THE SHORTEST, STRAIGHTEST DUCT ROUTING POSSIBLE FOR

BEST PERFORMANCE, AND AVOID INSTALLING THE FAN WITH SMALLER DUCTS THAN

RECOMMENDED. INSULATION AROUND THE DUCTS CAN REDUCE ENERGY LOSS AND

INHIBIT MOLD GROWTH. FANS INSTALLED WITH EXISTING DUCTS MAY NOT ACHIEVE

THEIR RATED AIRFLOW.

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN

THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY

INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY

AND/OR PROPERTY DAMAGE!

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precautions should always

be followed to reduce the risk of fire, electric shock and injury to

person, including the following:

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INSTALLATION INSTRUCTIONS; SECTION 1; SECTION 2; SECTION 3; SECTION 4; Figure 2; Horizontal

INSTALLATION INSTRUCTIONS CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. SECTION 1 Preparing the Range Hood 1. Unpack hood from the carton and confirm that all pieces are present. In addition to the range hood you should have: 1 - Aluminum Grease Filter 1 - G...

Page 3 - SECTION 5; Figure 6; Keyhole; SECTION 6; Tab; Figure 5; Damper; Figure 7

www.airkinglimited.com 6728046 Rev. G 11-16 3 of 12 NOTE : If installing into existing construction and you will not have access to the ductwork once the hood is in place, make ducting connections at this point. Refer to the Ducting Section for instructions. 5. Install the 4 mounting screw at the pr...

Page 4 - Troubleshooting Guide; Trouble; SECTION 9; Figure 9

CAUTION: ALWAYS DUCT THE FAN TO THE OUTSIDE THROUGH A WALL OR ROOF CAP. SECTION 7 Finishing the Installation 1. Install the filter by fitting the filter into the channel on the hood and sliding it back until it stops against the back of the hood (Figure 9). 2. Turn switches to the “OFF” position and...

Other Air King Range Hoods Models