Table of Contents:

  • Page 2 – SECONDARY SUPPORT CABLE; OPERATION; MAINTENANCE; LIMITED WARRANTY
  • Page 3 – LEA Y GUARDE ESTAS INSTRUCCIONES; GUARDE LAS INSTRUCCIONES PARA REFERENCIAS FUTURAS.; MANUAL DE INSTRUCCIONES DE OPERACIÓN Y PARTES; INSTALACIÓN EN PAREDES / TECHOS; DESCRIPCIÓN; VENTILADOR DE ALTA VELOCIDAD Y; CONSERVE ESTAS; INFORMACIÓN GENERAL DE SEGURIDAD; Al usar aparatos eléctricos, las precauciones básicas
  • Page 4 – OPERACIÓN; Este ventilador debe ser usa do solmente en; MANTENIMIENTO; GARANTÍA LIMITADA
Loading the manual

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DE-

SCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY

WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

OPERATING INSTRUCTIONS & PARTS MANUAL

WALL/CEILING INSTALLATION

1.

WOOD STRUCTURES:

Locate the wall or ceiling stud nearest

to the desired Fan location. Attach the Fan to the stud using a
3/8" diameter x 2" long Lag Screw (Not Supplied).

(Figure 1)

NOTE:

ALWAYS INSTALL THE YOKE TO A MINIMUM OF 2 X 4

STUDDING.
2.

STEEL STRUCTURES:

Attach the Fan using a 3/8" bolt of

the appropriate length, with a Flat Washer, Lock Washer and
a 3/8" Nut (Not Supplied).

3.

MASONARY STRUCTURES:

Attach Fan using a 3/8" Lag

Screw, with a Lag Shield of appropriate length (Not Supplied).

(Figure 1)

4. Attach Pull Cord String and Pendant to Switch.

Figure 1

Lag Screw

Wall or Ceiling Stud

Flat Washers

Lag Shield

(Masonary Only)

HIGH VELOCITY

MULTI MOUNT FAN

18" (45.7 cm) MODEL 9318

DESCRIPTION

The Air King® 18" (45.7 cm) Multi Mount Fan features Pull Cord operation and

a 3-paddle Fan Blade. This Fan has a permanently lubricated motor with a 9 ft

(2.74 m) 18/3 cord set and are constructed of sturdy, powder coated steel.

SPECIFICATIONS

Motor ...................................... 120V, 60 Hz

Blade diameter ........................ 18" (45.7 cm)

Speeds .................................... 3

Control ..................................... Pull Cord

Air flow distribution .................. 360°

Approvals................................. UL Listed. Close mesh Fan guard

meets OSHA requirements.

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precau-

tions should always be followed to reduce the

risk of fire, electric shock and injury to person,

including the following:

1. Read all instructions before using Fan.

2. Make certain that the power source conforms to the electrical require-

ments of the Fan.

3. Use this Fan only as described in this manual. Any other use not

recommended by the manufacturer may cause fire, electrical shock, or

injury to persons.

4. Unplug power cord before installing, servicing, or moving the Fan.

WARNING:

DO NOT DEPEND UPON THE ON-OFF SWITCH

AS THE SOLE MEANS OF DISCONNECTING POWER WHEN

INSTALLING OR SERVICING THE FAN. ALWAYS UNPLUG THE

POWER CORD.

5. This Fan must NOT be used in potentially dangerous locations such as

flammable, explosive, chemical-laden or wet atmospheres.

6. The power cord is equipped with a three-prong grounded plug that must be

inserted into a matching receptacle. Under no circumstances should the

grounding prong be cut off the plug. Where a two-prong wall receptacle

is encountered, it must be replaced with a properly grounded three-prong

receptacle installed in accordance with the National Electrical Code (NEC)

and all applicable local codes and ordinances. This work must be done
only by a qualified electrician, using copper wire only.

WARNING: USE OF A THREE-PRONG TO TWO-PRONG ADAPTER

IS NOT RECOMMENDED. IMPROPER CONNECTION MAY CREATE

THE RISK OF ELECTROCUTION. USE OF SUCH ADAPTERS IS

NOT PERMITTED IN CANADA.

WARNING: THIS PLUG IS A SAFETY FEATURE. TO REDUCE THE

RISK OF FIRE, ELECTRIC SHOCK AND PERSONAL INJURY,

DO NOT REMOVE, REPLACE, REPAIR OR TAMPER WITH

THE ORIGINALLY SUPPLIED PLUG. IF THE FAN DOES NOT

FUNCTION PROPERLY, IT MAY BE DUE TO THE SAFETY DEVICE

INCORPORATED IN THIS PLUG. RETURN TO AN AUTHORIZED

SERVICE CENTER OR CALL 800-233-0268, MONDAY - FRIDAY,

BETWEEN 8:00 AM AND 5:00 PM EST. IF THE PLUG WARNING

LABEL IS MISSING OR DAMAGED, CALL THE TOLL FREE

NUMBER FOR A REPLACEMENT LABEL.

7. Where possible, avoid the use of extension cords. If they must be used,

minimize the risk of overheating by ensuring that they are UL listed. Never

use a single extension cord to operate more than one Fan.

8. Do not operate any Fan with a damaged cord or plug after the Fan

malfunctions, has been dropped or damaged in any manner. Return

Fan to authorized service facility for examination, electrical or mechanical

adjustment or repair.

9. Do not insert or allow fingers or foreign objects to enter any ventilation

or exhaust opening as it may cause an electric shock, fire, or damage

the Fan. Do not block or tamper with the Fan in any manner while it

is in operation.

10.Always place the Fan on a stable, flat, level surface when operating, to

avoid the chance of the Fan overturning. Locate the Power Cord so

the Fan or other objects are not resting on it. Do not run Power Cord

under carpeting. Do not cover Power Cord with throw rugs, runners,

or the like. Arrange Power Cord away from room traffic and where it

will not be tripped over.

11.This Fan is not intended for use in wet or damp locations. Never locate

a Fan where it may fall into a bathtub or other water container.

12. Do not use Fan outdoors.

13.This Fan is not suitable for use in hazardous locations. Please refer to

National Electric Code (NEC) Article 500 or applicable state or local

codes or standards relating to electrical requirements for Hazardous

locations.

THIS FAN DOES NOT MEET THE REQUIRMENTS OF NEC

ARTICLE 500 (2002).

WARNING:

REDUCE THE RISK OF FIRE OR ELECTRIC

SHOCK – DO NOT USE THIS FAN WITH ANY SOLID STATE

SPEED CONTROL DEVICES.

SAVE THESE

INSTRUCTIONS

1

Rev. B 9/07

5084577

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SECONDARY SUPPORT CABLE; OPERATION; MAINTENANCE; LIMITED WARRANTY

MODEL 9318 CAUTION: THE SECONDARY SUPPORT CABLE PROVIDED SHOULD BE USED ANYTIME THE CIRCULATOR IS MOUNTED OVERHEAD FOR ADDITIONAL SAFETY. SECONDARY SUPPORT CABLE 1. Loop one end of Cable around the Large Diameter Wires of both the Front and Rear Circulator Guard. (Figure 2) 2. Attach a Cable Clamp w...

Page 3 - LEA Y GUARDE ESTAS INSTRUCCIONES; GUARDE LAS INSTRUCCIONES PARA REFERENCIAS FUTURAS.; MANUAL DE INSTRUCCIONES DE OPERACIÓN Y PARTES; INSTALACIÓN EN PAREDES / TECHOS; DESCRIPCIÓN; VENTILADOR DE ALTA VELOCIDAD Y; CONSERVE ESTAS; INFORMACIÓN GENERAL DE SEGURIDAD; Al usar aparatos eléctricos, las precauciones básicas

MANUAL DE INSTRUCCIONES DE OPERACIÓN Y PARTES LEA Y GUARDE ESTAS INSTRUCCIONES LÉALAS CUIDADOSAMENTE ANTES DE INTENTAR ARMAR, INSTALAR, OPERAR O DAR MANTENIMIENTO AL PRODUCTO DESCRITO. PROTÉJASE A SÍ MISMO Y A LOS DEMÁS OBSERVANDO TODA LA INFORMACIÓN SOBRE SEGURIDAD. ¡NO SEGUIR LAS INSTRUCCIONES POD...

Page 4 - OPERACIÓN; Este ventilador debe ser usa do solmente en; MANTENIMIENTO; GARANTÍA LIMITADA

MODELO 9318 3. ESTRUCTURAS DE MAMPOSTERÍA: Fijar el Ventilador de longitud adecuada (No Suministrado). NOTA: EN TODOS LOS CASOS SE RECOMIENDA QUE SE COLOQUE UNA ARANDELA PLANA EN AMBOS LADOS DE LA HORQUILLA DEL VENTILADOR PARA CONTRIBUIR A QUE EL GIRO SEA SUAVE. 4. Fije el cordón accionador y la pie...

Other Air King Models