Air King 9224 - Manual

Air King 9224

Air King 9224 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
Page: / 4

Table of Contents:

  • Page 2 – GARANTÍA LIMITADA; STAND ASSEMBLY; MAINTENANCE
  • Page 3 – above is made or authorized by AirKing.; LIMITED WARRANTY; MANTENIMIENTO; SIEMBRE DESENCHUFE EL CABLE; A D V E R T E N C I A :; ¡ N O S U M E R J A E L V E N T I L A D O R; ARMADO DEL PEDESTAL
  • Page 4 – ESPECIFICACIONES; MANUAL DE INSTRUCCIONES DE OPERACIÓN Y PARTES; MANTENIMIENTO AL PRODUCTO DESCRITO.; DESEMPACADO; A DV E R T E N C I A :; CONSERVE ESTAS
Loading the manual

Rev. J 9/06

8

5084028

Rev. J 9/06

1

5084028

* Articulo Incluyendo el numero de Empaques 5098012
** Patas de caucho con remache no incluidas

Ref.

NO. DE PARTE

DESCRIPCIÓN

CANT.

1

02084613

Adorno Tipo Ojo de Buey

1

2

5097021BK

Rejilla Delantera

1

3

5081015BKB

Paleta

1

4

5090012

Tornillos 5/16-24

1

5

2091212Z

Tornillos del motor 10-32 x 5/16

5

6

5097020BK

Rejilla Trasera con Placa de

1

Pivote Con Hexagonal

7

*

Perno de 1/4-20 x 1

4

8

5062086BK

Patas

2

9

*

Arandela de Seguridad

2

10

*

Tuerca de 1/4-20

2

11

02030024SK

Perilla del Interruptor

1

12

02030024SW

Interruptor

1

13

02030224

Conjunto del Motor

1

14

02030024CS

Juego de Alambre Flexible

1

15

5062211BK

Manija

1

16

05010051

Empuñadura de la manija

1

17

5090050

Eje tapa Perno

2

18

05010050

Ruedas

2

19

5062215BK

La Barra del Eje

1

20

5062215BK

Escuadra de montaje

1

21

2090058B

Tornillo #8 X 7/16

2

22

02011601

Espaciador de caucho

2

6

5

13

8

9

12

11

10

7

2

3

1

14

9

7

10

4

17

18

21

20

19

17

18

16

15

22

22

SPECIFICATIONS

Motor ................................. 120V , 50/60 Hz
Blade diameter .................. 24" (60.96cm) Model9224
Speeds .............................. 3
Control .............................. Rotary Switch
Air flow distribution ........... 190˚
Approvals .......................... UL Listed. Close mesh fan guard

meets OSHA requirements.

DESCRIPTION

The AirKing 24" (60.96 cm) pivot/floor fan features 3-speed operation
with a 3-paddle fan blade. The fan has an enclosed motor with
permanently lubricated ball bearings with a 10 ft (3.05 m) 18/3 cord set,
and is constructed of sturdy powder coated steel.

24" FLOOR FAN

24" (60.96cm) MODEL 9224

OPERATING INSTRUCTIONS & PARTS MANUAL

MODELO 9224

UNPACKING

When unpacking the unit, inspect carefully for any damage that
may have occurred during transit. Check for loose, missing, or
damaged parts.

GENERAL SAFETY INFORMATION

1. Read all instructions before using Fan.
2. Make certain that the power source conforms to the electrical

requirements of the Fan.

3. Use this Fan only as described in this manual. Any other use not

recommended by the manufacturer may cause fire, electrical
shock, or injury to persons.

4. To reduce the risk of personal injury and electric shock, the Fan should

not be played with or placed where small children can reach it.

5. Unplug power cord before installing, servicing, or moving the Fan.

WARNING:

DO NOT DEPEND UPON THE ON-OFF SWITCH AS

THE SOLE MEANS OF DISCONNECTING POWER WHEN IN-
STALLING OR SERVICING THE FAN. ALWAYS UNPLUG THE
POWER CORD.

6. T h i s F a n m u s t N O T b e u s e d i n p o t e n t i a l l y d a n g e r o u s

l o c a t i o n s s u c h a s f l a m m a b l e , e x p l o s i v e , c h e m i c a l - l a d e n
o r w e t a t m o s p h e r e s .

7. D O N O T u s e F a n i n or near a w i n d o w . R a i n m a y c r e a t e a n

e l e c t r i c a l h a z a r d .

8. Completely assemble Fan, according to instructions, before

connecting to power supply.

9. The power cord is equipped with a three-prong grounded plug

that must be inser ted into a matching receptacle. Under no cir-
cumstances should the ground prong be cut off the plug. Where
a two-prong wall receptacle is encountered, it must be replaced
with a properly grounded three-prong receptacle installed in ac-
cordance with the National Electrical Code (NEC) and all appli-
cable local codes and ordinances. This work must be done by a
qualified electrician, using copper wires only.

WARNING:

DO NOT USE A THREE-PRONG ADAPTER. IM-

PROPER CONNECTION MAY CAUSE THIS RISK OF ELEC-
TROCUTION. USE OF SUCH ADAPTERS IS NOT PERMITTED
IN CANADA.

10. Where possible, avoid the use of extension cords. If they must be

used, minimize the risk of overheating by ensuring that they are
UL listed. Never use a single extension cord to operate more than
one Fan.

11. Do not operate any Fan with a damaged cord or plug or after the

Fan malfunctions, has been dropped or damaged in any manner.
Return Fan to authorized service facility for examination, electrical
or mechanical adjustment or repair.

12. Do not inser t or allow fingers or foreign objects to enter any

ventilation or exhaust opening as it may cause an electric shock
or fire, or damage the Fan. Do not block or tamper with the Fan
in any manner while it is in operation.

13.Always place the Fan on a stable, flat, level surface when

operating, to avoid the chance of the Fan overturning. Locate the
Power Cord so the Fan or other objects are not resting on it. Do
not run Power Cord under carpeting. Do not cover Power Cord
with throw rugs, runners, or the like. Arrange Power Cord away
from room traffic and where it will not be tripped over.

1 4. T h i s Fa n i s n o t i n t e n d e d fo r u s e i n we t o r d a m p l o c a t i o n s.

N eve r l o c a t e a Fa n w h e r e i t m ay fa l l i n t o a b a t h t u b o r o t h e r
wa t e r c o n t a i n e r.

15. Do not use Fan outdoors.

WARNING:

REDUCE THE RISK OF FIRE OR ELECTRIC

SHOCK – DO NOT USE THIS FAN WITH ANY SOLID STATE
SPEED CONTROL DEVICES.

SAVE THESE

INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.

PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH

INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

MODEL

9224

SPEED

HIGH

MED

LOW

CFM

5130

4490

3670

M

3

/s

2.42

2.12

1.73

RPM

1500

1250

1000

Amps

2.03

1.81

1.63

Watts

229

200

176

dB A

72

69

64

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - GARANTÍA LIMITADA; STAND ASSEMBLY; MAINTENANCE

Rev. J 9/06 2 5084028 Rev. J 9/06 7 5084028 MODEL 9224 MODELO 9224 GARANTÍA LIMITADA DE TRES AÑOS DE AIRKING. AirKing garantiza el producto al usuarlo original, contra defectos de mano de obra o materiales en condiciones de uso normales. El motor está garantizado por tres años y todas las demás part...

Page 3 - above is made or authorized by AirKing.; LIMITED WARRANTY; MANTENIMIENTO; SIEMBRE DESENCHUFE EL CABLE; A D V E R T E N C I A :; ¡ N O S U M E R J A E L V E N T I L A D O R; ARMADO DEL PEDESTAL

Rev. J 9/06 6 5084028 Rev. J 9/06 3 5084028 MODEL 9224 MODELO 9224 AIRKING THREE-YEAR LIMITED WARRANTY. Products are warranted by AirKing to the original user against defects in workmanship or materials under normal use for three years on the motor and one year on all other parts, after date of purc...

Page 4 - ESPECIFICACIONES; MANUAL DE INSTRUCCIONES DE OPERACIÓN Y PARTES; MANTENIMIENTO AL PRODUCTO DESCRITO.; DESEMPACADO; A DV E R T E N C I A :; CONSERVE ESTAS

Rev. J 9/06 4 5084028 Rev. J 9/06 5 5084028 6 5 13 8 9 12 11 10 7 2 3 1 14 9 7 10 4 17 18 21 20 19 17 18 16 15 22 * Items included in Parts Bag 5098012** Rubber feet with rivets not available Key Part Number Description Qty . 1 02084613 Bullseye 1 2 5097021BK Front Grill 1 3 5081015BKB Blade 1 4 509...

Other Air King Models

All Air King Other