Air King 4C631P/9016P - Manual

Air King 4C631P/9016P

Air King 4C631P/9016P – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
Page: / 4

Table of Contents:

  • Page 2 – ASSEMBLY; GARANTÍA LIMITADA
  • Page 3 – VENTILADORES OSCILANTES DE MONTAJE EN PARED; CONSERVE ESTAS; INFORMACIÓN GENERAL DE SEGURIDAD; LEA Y GUARDE ESTAS INSTRUCCIONES; GUARDE LAS INSTRUCCIONES PARA REFERENCIAS FUTURAS.; MANUAL DE INSTRUCCIONES DE OPERACIÓN Y PARTES
  • Page 4 – LIMITED WARRANTY; INSTALACIÓN
Loading the manual

4

29

1

2

3

31

32

33

34

35

36

37

35

9

30

8

6

12

11

7

28

26

7

13

14

15

16

4

17

18

22

21

22

20

25

4 24

23

18

19

10

27

5

DESCRIPTION

AirKing 12" (30.4 cm) and 16" (40.6 cm) Wall Mounted Oscillating
Fans offer pull cord speed control, variable oscillation, a permanent
split capacitor motor and OSHA-complying front steel mesh grill with
a 6 ft (1.8m) 18/3 cord set.

SPECIFICATIONS

Motor ................................. 120V, 60 Hz (12", 30.4 cm)

120V, 60 Hz (16", 40.6 cm)

Blade diameter .................. 12" ( 30.4 cm) Model 4C630N/9012N

16" (40.6 cm) Model 4C631P/9016P

Speeds .............................. 3
Control .............................. Pull Cord
Air flow distribution ........... 90

°

Approvals .......................... UL Listed. Close mesh Fan Guard

meets OSHA requirements.

1

2084060A

Rev. P 3/05

WALL MOUNTED
OSCILLATING FANS

12" (30.4 cm) MODEL 4C630N/9012N
16" (40.6 cm) MODEL 4C631P/9016P

MODEL

4C630N/9012N

4C631P/9016P

SPEED

HIGH

MED

LOW

HIGH

MED

LOW

CFM

930

780

620

1710

1500

1330

M

3

/s

0.44

0.37

0.29

0.80

0.71

0.63

RPM

1450

1300

1090

1545

1394

1244

Amps

0.40

0.30

0.27

0.71

0.54

0.48

Watts

39

35

32

77

65

57

dBA

45

41

36

53

49

44

8

2084060A

Rev. P 3/05

MODELO 4C630N/9012N y 4C631P/9016P

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precau-
tions should always be followed to reduce the
risk of fire, electric shock and injury to person,
including the following:

1. Read all instructions before using Fan.
2. Make certain that the power source conforms to the electrical

requirements of the Fan.

3. Use this Fan only as described in this manual. Any other use not

recommended by the manufacturer may cause fire, electrical
shock, or injury to persons.

4. Unplug power cord before installing, servicing, or moving the Fan.

WARNING:

DO NOT DEPEND UPON THE ON-OFF

SWITCH AS THE SOLE MEANS OF DISCONNECTING
POWER WHEN INSTALLING OR SERVICING THE FAN.
ALWAYS UNPLUG THE POWER CORD.

5. T h i s F a n m u s t N O T b e u s e d i n p o t e n t i a l l y d a n g e r o u s

l o c a t i o n s s u c h a s f l a m m a b l e , e x p l o s i v e , c h e m i c a l - l a d e n
o r w e t a t m o s p h e r e s .

6. D O N O T u s e F a n i n or near a w i n d o w . R a i n m a y c r e a t e a n

e l e c t r i c a l h a z a r d .

7. The power cord is equipped with a three-prong grounded plug

that must be inserted into a matching receptacle. Under no

circumstances must the grounding prong be cut off the plug.
Where a two-prong wall receptacle is encountered, it must be
replaced with a properly grounded three-prong receptacle in-
stalled in accordance with the National Electrical Code (NEC)
and all applicable local codes and ordinances. This work must
be done only by a qualified electrician, using copper wire only.

WARNING:

USE OF A THREE-PRONG TO TWO-PRONG

ADAPTER IS NOT RECOMMENDED. IMPROPER CON-
NECTION MAY CREATE THE RISK OF ELECTROCUTION.
USE OF SUCH ADAPTERS IS NOT PERMITTED IN CANADA.

WARNING:

THIS PLUG IS A SAFETY FEATURE. TO

REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND
P E R S O N A L I N J U RY, D O N OT R E M OV E , R E P L AC E ,
REPAIR OR TAMPER WITH THE ORIGINALLY SUPPLIED
PLUG. IF THE FAN DOES NOT FUNCTION PROPERLY, IT
MAY BE DUE TO THE SAFETY DEVICE INCORPORATED
IN THIS PLUG. RETURN TO AN AUTHORIZED SERVICE
CENTER OR CALL 800-233-0268, MONDAY - FRIDAY,
BETWEEN 8:30 AM AND 4:00 PM EST. IF THE PLUG
WARNING LABEL IS MISSING OR DAMAGED, CALL THE
TOLL FREE NUMBER FOR A REPLACEMENT LABEL.

8. Where possible, avoid the use of extension cords. If they must be

used, minimize the risk of overheating by ensuring that they are
UL listed. Never use a single extension cord to operate more
than one Fan.

9. Do not operate any Fan with a damaged cord or plug or after the

Fan malfunctions, has been dropped or damaged in any manner.
Return Fan to authorized service facility for examination, electrical
or mechanical adjustment or repair.

10.Do not inser t or allow fingers or foreign objects to enter any

ventilation or exhaust opening as it may cause an electric shock
or fire, or damage the Fan. Do not block or tamper with the Fan
in any manner while it is in operation.

11.Always place the Fan on a stable, flat, level surface when

operating, to avoid the chance of the Fan overturning. Locate the
Power Cord so the Fan or other objects are not resting on it. Do
not run Power Cord under carpeting. Do not cover Power Cord
with throw rugs, runners, or the like. Arrange Power Cord away
from room traffic and where it will not be tripped over.

1 2. T h i s Fa n i s n o t i n t e n d e d fo r u s e i n we t o r d a m p l o c a t i o n s.

N eve r l o c a t e a Fa n w h e r e i t m ay fa l l i n t o a b a t h t u b o r o t h e r
wa t e r c o n t a i n e r.

13. Do not use Fan outdoors.

WARNING:

REDUCE THE RISK OF FIRE OR ELECTRIC

SHOCK – DO NOT USE THIS FAN WITH ANY SOLID STATE
SPEED CONTROL DEVICES.

SAVE THESE

INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT

DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO

COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

OPERATING INSTRUCTIONS & PARTS MANUAL

LISTA DE REPUESTOS

1

2010119

2010119

Botón de Oscilación

1

2

02030062GL

02030066GL

Motor

1

3

2010665

2010665

Cubierta del Motor (Frontal)

1

4

02090040

02090040

Tornillo de la Cubierta Tipo B
#7 x 7/16" PTH

3

5

02090140

02090140

Tornillo de Enlace

2

6

2010276

2010276

Enlace

1

7

02010548A

02010548A

Boton Tipo H.C.

2

8

02010163

02010163

Cubierta de la Pieza del Cuello

1

9

02010162B

02010162B

Placa de Trinquete

1

10

2010165

2010165

Bola de Oscilación Doble con
Resorte

1

11

2010252

2010252

Pieza del Cuello

1

12

02090051

02090051

Tornillo Phillips de Cabeza
Reforzada #7 x .390 PTH

1

13

2010131

2010131

Botón del Interruptor (Rotatorio) 1

14

02050009AWFPC

02050009AWFPC

Cordón Eléctrico

1

15

02090744

02090744

Tire Cuerda

1

16

2090539

2090539

Casquillo del Cordón Accionador 1

17

02090272

02090272

Pata de Caucho

2

18

02090045A

02090045A

Tornillo Phillips Tipo 25 #8 x 3/4" 6

19

2010552

2010552

Tapa del Interruptor

1

20

2060202

2060202

Placa Tracera para Colgar

1

21

2060316

2060316

Placa de Montaje

1

22

2090003

2090003

Tornillo Phillips #8 x 1-1/4"

2

23

2090529

2090529

Tuerca para Alambre

2

24

02055047

02055047

Interruptor con Cordón
Accionador

1

25

2010512P

2010512P

Cuerpo

1

26

02090521A

02090521A

Eje de Elevación

1

27

02090518

02090518

Resorte de Elevación

1

28

02090033

02090033

Tuerca Hexagonal

1

29

2010661

2010661

Cubierta del Motor (Trasera)

1

30

07091657

07091657

Vástago del Motor

1

31

02090060

02090060

Tornillo #7 x .8 PPH ZP Tipo B

2

32

2011212

2011200M

Rejilla Plástica Trasera

1

33

2010359

2010359

Tuerca de la Rejilla

1

34

2010008

2011013

Paletas

1

35

2010058

2010059

Tapa

1

36

02096217

02096214I

Rejilla Frontal

1

37

02010381A

02010381A

Ornamento de la Rejilla

1

Ref.

Parte No. for Modelo

No.

4C630M/9012M

4C631N/9016N

Descripción

Cant.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - ASSEMBLY; GARANTÍA LIMITADA

2 MODEL 4C630N/9012N and 4C631P/9016P Rev. P 3/05 7 2084060A Rev. P 3/05 2084060A GARANTÍA LIMITADA MODELO 4C630N/9012N y 4C631P/9016P Motor Detail 1 Rear Grill Plastic Nut Blade Spinner Front Grill Ornament ASSEMBLY (Figure 1) 1. Put Rear Grill on Motor by aligning the tab on the Rear Grill with th...

Page 3 - VENTILADORES OSCILANTES DE MONTAJE EN PARED; CONSERVE ESTAS; INFORMACIÓN GENERAL DE SEGURIDAD; LEA Y GUARDE ESTAS INSTRUCCIONES; GUARDE LAS INSTRUCCIONES PARA REFERENCIAS FUTURAS.; MANUAL DE INSTRUCCIONES DE OPERACIÓN Y PARTES

2084060A Rev. P 3/05 5 2084060A Rev. P 3/05 MODEL 4C630N/9012N and 4C631P/9016P DESCRIPCIÓN Los Ventiladores Oscilantes AirKing de 12" (30.4 cm) y 16" (40.6 cm)para Montaje en Pared cuentan con un control de velocidad accionadopor un cordón, oscilación variable, un motor de condensador dediv...

Page 4 - LIMITED WARRANTY; INSTALACIÓN

6 2084060A Rev. P 3/05 3 2084060A Rev. P 3/05 MODEL 4C630N/9012N and 4C631P/9016P MODELO 4C630N/9012N y 4C631P/9016P AIRKING THREE-YEAR LIMITED WARRANTY. Products are warranted by AirKing to the original user against defects inworkmanship or materials under normal use for three years on the motor an...

Other Air King Models

All Air King Other