Air King AK55L - Manual

Air King AK55L

Air King AK55L – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
Page: / 1
Loading the manual

SPECIFICATIONS

EXHAUST FANS

AK55L

1350 watts - 70 CFM/5.0 SONES @ 0.10" wg.

HVI CERTIFIED 120 Volts, 11.2 amps, 60 hz.

Grill

White, polymeric grill (flame retardant ABS UL rated 94-5V)
secured in place using 2 hex nuts that can be easily removed
if necessary, dimensions - 17

1/8

" x 9

7/8

".

Light Lens

Moonstone glass lens, installed in a flip down lens holder.
Secured in place using integral tabs.

• Blower Wheels

Heater blower wheel - one piece metal electronically balanced,

3

11/16

" x 2" with 28 fins.

Ventilation blower wheel - one piece polymeric electronically

balanced, 4

5/8

" x 1" with 10 fins.

• Motors

Heater motor - Heavy duty, plug in 2 pole motor. Life time

lubrication, thermally protected.
Rated 120 volts, 60 hz., 0.90 amps., 2400 rpm.

Ventilation motor - Heavy duty, plug in 2 pole motor. Life time

lubrication, thermally protected.
Rated 120 volts, 60 hz., 1.2 amps.

• Heater Housing

23 gauge galvanized steel housing. Dimensions 14

1/2

" x 8

3/8

" x 6

1/2

".

• Heating Element

Ultra safe ceramic heating element bonded to large heat transfer
surface allows heating at very low operating temperature. Self
regulating design provides 1,350 Watts – 4,600 Btu.

• Duct Collar

4" round, zinc plated metal collar adapter with aluminum
backdraft damper.

CUL/HVI - TYPE IC RATED

Canada:

110 Glidden Road

Brampton, Ontario L6T 2J3
Tel: (905) 456-2033
Fax: (905) 456-1015

U.S.:

820 Lincoln Drive

West Chester, Pennsylvania 19380-4466
Tel: (877)-304-3785
Fax: (610) 696-8048

Updated 5-06

Specifications subject to change without notice.

• Ventilating Area

For bathrooms up to 70 sq. ft. For other rooms up to 85 sq. ft.

• Lamping Information

Up to 100 watt incandescent capacity, type A lamp required.

• Unit Mounting

Designed for ceilings insulated to R-40. Designed to mount in
ceilings with at least 7.5" of clearance. The unit will mount
between joists (with 16" centers) or butted up against a joist.
The housing will mount through drywall thickness up to

3/4

",

with a rough in opening of 14

3/4

" x 8

5/8

".

• Single Pack Shipping Info

Box Dim: 21

1/8

" x 11

1/4

" x 9

3/4

"

UPC: 0-83162901002
Shipping Weight: 16.09 lbs.

C

US

PROJECT

LOCATION

CONTRACTOR

ARCHITECT

ENGINEER

SUBMITTED BY

DATE

FAN

MODEL

CFM

IN

RPM

WATTS

AMPS

SONES

QTY

OPTIONAL EQUIPMENT

NUMBER NUMBER

W.G.

& REMARKS

PERFORMANCE

HVI Sones

Fan Speed

Power

Static Pressure (inches of w.g.)

@ .1 SP

RPM

Watts

0

0.05

0.1

0.15

0.2

0.25

0.3

0.35

Air Flow - CFM

76

73

70

67

64

61

57

53

5.0

2575

54

6

1/2

"

4"

14

1/2

"

9

7/8

"

17

1/8

"

8

3/8

"

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Air King Models

All Air King Other