Air King AK55L - Manual
Air King AK55L – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
SPECIFICATIONS
EXHAUST FANS
AK55L
1350 watts - 70 CFM/5.0 SONES @ 0.10" wg.
HVI CERTIFIED 120 Volts, 11.2 amps, 60 hz.
•
Grill
White, polymeric grill (flame retardant ABS UL rated 94-5V)
secured in place using 2 hex nuts that can be easily removed
if necessary, dimensions - 17
1/8
" x 9
7/8
".
•
Light Lens
Moonstone glass lens, installed in a flip down lens holder.
Secured in place using integral tabs.
• Blower Wheels
Heater blower wheel - one piece metal electronically balanced,
3
11/16
" x 2" with 28 fins.
Ventilation blower wheel - one piece polymeric electronically
balanced, 4
5/8
" x 1" with 10 fins.
• Motors
Heater motor - Heavy duty, plug in 2 pole motor. Life time
lubrication, thermally protected.
Rated 120 volts, 60 hz., 0.90 amps., 2400 rpm.
Ventilation motor - Heavy duty, plug in 2 pole motor. Life time
lubrication, thermally protected.
Rated 120 volts, 60 hz., 1.2 amps.
• Heater Housing
23 gauge galvanized steel housing. Dimensions 14
1/2
" x 8
3/8
" x 6
1/2
".
• Heating Element
Ultra safe ceramic heating element bonded to large heat transfer
surface allows heating at very low operating temperature. Self
regulating design provides 1,350 Watts – 4,600 Btu.
• Duct Collar
4" round, zinc plated metal collar adapter with aluminum
backdraft damper.
CUL/HVI - TYPE IC RATED
Canada:
110 Glidden Road
Brampton, Ontario L6T 2J3
Tel: (905) 456-2033
Fax: (905) 456-1015
U.S.:
820 Lincoln Drive
West Chester, Pennsylvania 19380-4466
Tel: (877)-304-3785
Fax: (610) 696-8048
Updated 5-06
Specifications subject to change without notice.
• Ventilating Area
For bathrooms up to 70 sq. ft. For other rooms up to 85 sq. ft.
• Lamping Information
Up to 100 watt incandescent capacity, type A lamp required.
• Unit Mounting
Designed for ceilings insulated to R-40. Designed to mount in
ceilings with at least 7.5" of clearance. The unit will mount
between joists (with 16" centers) or butted up against a joist.
The housing will mount through drywall thickness up to
3/4
",
with a rough in opening of 14
3/4
" x 8
5/8
".
• Single Pack Shipping Info
Box Dim: 21
1/8
" x 11
1/4
" x 9
3/4
"
UPC: 0-83162901002
Shipping Weight: 16.09 lbs.
C
US
PROJECT
LOCATION
CONTRACTOR
ARCHITECT
ENGINEER
SUBMITTED BY
DATE
FAN
MODEL
CFM
IN
RPM
WATTS
AMPS
SONES
QTY
OPTIONAL EQUIPMENT
NUMBER NUMBER
W.G.
& REMARKS
PERFORMANCE
HVI Sones
Fan Speed
Power
Static Pressure (inches of w.g.)
@ .1 SP
RPM
Watts
0
0.05
0.1
0.15
0.2
0.25
0.3
0.35
Air Flow - CFM
76
73
70
67
64
61
57
53
5.0
2575
54
6
1/2
"
4"
14
1/2
"
9
7/8
"
17
1/8
"
8
3/8
"
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.