Air King BFQ110 - Manual
Air King BFQ110 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – SECTION 3; Existing Construction; SECTION 4; Ducting; INSTALLATION INSTRUCTIONS; MAKE SURE POWER IS SWITCHED OFF AT; SECTION 1; Preparing the Exhaust Fan; SECTION 2; New Construction
- Page 3 – SECTION 7; Use and Care; Finishing the Installation; SECTION 5; Wiring; SECTION 6; Completing the Installation; Troubleshooting Guide; Trouble; Figure 7; Ground; Figure 8
- Page 4 – MONDAY THROUGH FRIDAY, BETWEEN THE HOURS OF 8 AM AND 4:00 PM EST.
- Page 5 – LIRE ET CONSERVER CES INSTRUCTIONS; CONSERVER CES INSTRUCTIONS POUR RÉFÉRENCES FUTURES.; INSTRUCTIONS GÉNÉRALES DE SÉCURITÉ; toujours être suivies pour réduire les risques d’incendie, de choc; CONSERVER CES INSTRUCTIONS; POUR USAGE DE VENTILATION; POUR RÉDUIRE LES RISQUES; NE JAMAIS; NE PAS UTILISER DANS LES CUISINES; INSTRUCTIONS IMPORTANTES –
- Page 6 – Construction Existante; Conduits; INSTRUCTIONS D’INSTALLATION; VOUS ASSURER QUE L’ALIMENTATION; Préparation du Ventilateur d’évacuation; Nouvelle construction
- Page 7 – Utilisation et entretien; Câblage; Complétion de l’installation; Fil de Masse; Alimentation; Guide de dépannage
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
electric shock and injury to person, including the following:
1.
Read all instructions before installing or using exhaust fan.
2.
Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer.
3.
Before servicing or cleaning the unit, switch power off at
service panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When
the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the
service panel.
4.
Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes
and standards, including fire-related construction.
5.
Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent back drafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA)
and the American Society for Heating, Refrigeration, and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
CAUTION:
FOR GENERAL VENTILATING USE ONLY. DO
NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS
AND VAPORS.
Models: BFQ50, BFQ70, BFQ75, BFQ90,
BFQ110, BFQ140, BFQ175
www.airkinglimited.com
2A0572021 Rev. C 6/06
Exhaust Fan
SAVE THESE INSTRUCTIONS
6.
When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
7.
Ducted fans must always be vented to the outdoors.
8.
This unit must be grounded.
9.
To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off
power unit.
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
DO NOT USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL
DEVICE.
10. Acceptable for use over a bathtub or shower when installed
in a GFCI protected branch circuit.
11. NEVER place a switch where it can be reached from a tub or
shower.
WARNING:
DO NOT USE IN KITCHENS
IMPORTANT INSTRUCTIONS -
OPERATING MANUAL
1 of 8
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2. Snap the fan body into the bracket (Figure 4) . The fan can be snapped into position with the duct collar facing to the leftor the right depending which is most convenient. SECTION 3 Existing Construction 1. Position housing against the joist or stud and trace an outlineof the housing onto the ce...
2. Install the grill by squeezing the two ends of the springstogether and installing them up into the slots of the fan’shousing. Push the grill up into position (Figure 9) . 3. Restore power and test your installation. SECTION 7 Use and Care CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL ...
LIMITED WARRANTY All products manufactured by Air King Limited are warranted for one year from the date of purchase against defects in workmanshipand/or material. In addition, all ventilating/exhaust fans, heaters, combination fan lights and/or heaters, and range hoods areguaranteed for five years f...