Page 2 - MACHINE DATA LOG/OVERVIEW; YOUR DEALER
MACHINE DATA LOG/OVERVIEW ENSIGN 98635 04/04/03 2 For the name and address of your dealer contact: Windsor Industries YOUR DEALER Name: __________________________________________________________________________________________________ Address: ________________________________________________________...
Page 3 - TABLE OF CONTENTS; HOW TO USE THIS MANUAL
TABLE OF CONTENTS ENSIGN 98635 03/26/04 3 Machine Data Log/Overview. ......................... 1Table of Contents ........................................... 2 HOW TO USE THIS MANUAL How to use this Manual. ................................ 1-1 SAFETY Important Safety Instructions ......................
Page 5 - SAFETY INSTRUCTIONS; IMPORTANT SAFETY INSTRUCTIONS; When using an electrical appliance, basic precaution; READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE.; SAVE THESE INSTRUCTIONS
SAFETY INSTRUCTIONS ENSIGN 98635 04/04/03 2-1 IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precaution must always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE. This machine is for commercial use. To reduce the risk of fire, electric...
Page 6 - HAZARD INTENSITY LEVEL; WARNING; CAUTION; WARNING; WARNING; CAUTION
HAZARD INTENSITY LEVEL ENSIGN 98635 04/04/03 2-2 The following symbols are used throughout this guide as indicated in their descriptions: HAZARD INTENSITY LEVEL There are three levels of hazard intensity identified by signal words - WARNING and CAUTION and FOR SAFETY. The level of hazard intensity i...
Page 7 - SAFETY LABEL LOCATION
SAFETY LABEL LOCATION ENSIGN 98635 04/04/03 2-3 NOTE: These drawings indicate the location of safety labels on the machine. If at any time the labels becomeillegible, promptly replace them. LABEL WARNING 500009
Page 8 - GROUNDING INSTRUCTIONS; GROUNDING INSTRUCTIONS:
GROUNDING INSTRUCTIONS ENSIGN 98635 04/04/03 2-4 THIS PRODUCT IS FOR COMMERCIAL USEONLY. ELECTRICAL: In the USA this machine operates on astandard 15 amp 115V, 60 hz, A.C. powercircuit . The amp, hertz, and voltage are listedon the data label found on each machine.Using voltages above or below those...
Page 9 - TECHNICAL SPECIFICATIONS; ITEM
TECHNICAL SPECIFICATIONS ENSIGN 98635 04/04/03 3-1 ITEM MEASURE Electrical 115 Volt, 60hz Vacuum Motor Single 3 stage Solution Pump 50 psi Solution Capacity 7 gal (26 L) Recovery Capacity 6 gal (22 L) Weight - Empty 50 lbs (110 kg) Weight –Full Solution 105 lbs (230 kg) Height 35 inches (88.90 cm) H...
Page 10 - CONTROLS; Vacuum Switch
CONTROLS ENSIGN 98635 04/04/03 3-2 1. Vacuum Switch 2. Pump Switch ON OFF OFF ON VAC PUMP 1 2
Page 11 - MACHINE OPERATION; For hose fitting lubrication; NOTE; EMPTYING AND CLEANING
MACHINE OPERATION ENSIGN 98635 04/04/03 3-3 GENERAL INFORMATIONAs the carpet is being cleaned, check to seeif there is foam building up in the recoverybucket. Add a little defoaming compound to the recovery tank but never to the solution tank. For infrequent use or long periods ofstorage , flush the...
Page 12 - MAINTENANCE; DAILY MAINTENANCE
MAINTENANCE ENSIGN 98635 04/04/03 4-1 Unplug power cord(s)before servicing ormaking any repairs . DAILY MAINTENANCE 1. Flush the entire system, including floor tool, hand tool, etc., with 1 to 3 gallons of clean, hotwater. 2. Vacuum out the solution tank. 3. Rinse tank with fresh water. Periodically...
Page 13 - perform the following repairs; Turn off all switches and unplug machine.
MAINTENANCE ENSIGN 98635 03/26/04 4-2 Only qualifiedmaintenancepersonnel are to perform the following repairs . VACUUM MOTOR REPLACEMENT 1. Turn off all switches and unplug machine. 2. Remove recovery tank. 3. Locate the vacuum motor wires and disconnect at the connector. 4. Remove the vacuum motor....
Page 14 - Turn off all switches and unplug the
MAINTENANCE ENSIGN 98635 03/26/04 4-3 Only qualifiedmaintenancepersonnel are to perform the following repairs . SOLUTION PUMP REPLACEMENT 1. Turn off all switches and unplug the machine. 2. Remove recovery tank. 3. Remove solution hoses from fittings in pump. 4. Remove the screws that fasten the pum...
Page 15 - TROUBLESHOOTING
TROUBLESHOOTING ENSIGN 98635 03/26/04 4-4 PROBLEM CAUSE SOLUTION Dead electrical circuit Check building circuit breaker or fuse box. Loss of Power Faulty power cord Replace Equipment not grounding Follow grounding instructions exactly Receptacle not grounded Contact an electrician to check building’...
Page 16 - PUMP GROUP
PUMP GROUP ENSIGN 98635 04/04/03 5-1 1 2 3 5 6 7 8 2 3 4
Page 18 - RECOVERY TANK GROUP
RECOVERY TANK GROUP ENSIGN 98635 03/18/05 5-3 3 4 5 6 9 10 11 12 1 4 16 17 18 2 0 21 2 2 23 2 4 13 15 26 15 1 27 7 8 1 9 2 32 25 28 29 30 31
Page 20 - SOLUTION TANK GROUP
SOLUTION TANK GROUP ENSIGN 98635 01/09/07 5-5 * * PARTS INSIDE TANK CONNECT TO PUMP ASM 4 5 7 8 6 6 1 2 9 10 41 6 11 12 6 14 13 15 18 19 22 20 21 17 16 23 24 28 29 30 18 31 32 33 34 35 38 37 39 39 40 36 3 26 27 25 23 42 43
Page 22 - VACUUM MOTOR GROUP
VACUUM MOTOR GROUP ENSIGN 98635 04/04/03 5-7 3 1 2 4 5
Page 24 - WIRING DIAGRAM
Page 25 - SUGGESTED SPARE PARTS
SUGGESTED SPARE PARTS ENSIGN 98635 03/26/04 5-10 PART NO. DESCRIPTION SERIAL NO. FROM NOTES: 34380 FLOAT SHUT OFF 260-64A ACCESS COVER CLEAR 6” W/RIM 11-800444 ELBOW, 1.5 FS X FS 45D PVC 72142 SWITCH SPST 15A EURO ROCKER 320-05 VELCRO STRAPS 35011 GASKET, 3/8T 5.7 VAC FAN SEAL 140-12 KNOB 1/4-20 X 3...
Page 26 - NOTES