Page 2 - MACHINE DATA LOG/OVERVIEW; YOUR DEALER
MACHINE DATA LOG/OVERVIEW CADET 86038340 04/19/07 2ENG For the name and address of your dealer contact: Windsor Industries YOUR DEALER Name: __________________________________________________________________________________________________ Address: ___________________________________________________...
Page 3 - TABLE OF CONTENTS; HOW TO USE THIS MANUAL
TABLE OF CONTENTS CADET 86038340 04/19/07 3ENG Machine Data Log/Overview (English). ........ 1 Machine Data Log/Overview (German). ....... 2 Table of Contents (English) .......................... 3 Table of Contents (German) ......................... 4 HOW TO USE THIS MANUAL How to use this Manual. ...
Page 5 - IMPORTANT SAFETY INSTRUCTIONS; When using an electrical appliance, basic precaution; READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE.; SAVE THESE INSTRUCTIONS
CADET 86038340 04/19/07 2-1ENG IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precaution must always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE. This machine is for commercial use. To reduce the risk of fire, electric shock, or inju...
Page 6 - HAZARD INTENSITY LEVEL; WARNING; WARNING; WARNING; CAUTION
HAZARD INTENSITY LEVEL CADET 86038340 04/19/07 2-2ENG The following symbols are used throughout this guide as indicated in their descriptions: HAZARD INTENSITY LEVEL There are three levels of hazard intensity identified by signal words - WARNING and CAUTION and FOR SAFETY. The level of hazard intens...
Page 7 - SAFETY LABEL LOCATION
SAFETY LABEL LOCATION CADET 86038340 04/19/07 2-3ENG NOTE: These drawings indicate the location of safety labels on the CDT7//10080230. If, at any time, the labels become illegible contact your Windsor representative for prompt replacement. WARNING DECAL 86242230 PRV NO. 500009
Page 8 - ACCESSORY TOOL USAGE; Turn on Pump and Vacuum Switch.
ACCESSORY TOOL USAGE CADET 86038340 04/19/07 3-10ENG Turn on Pump and Vacuum Switch. Note: Be sure intermittent/continuous switch is in center (off) position and brush is in storage position. Squeeze handle on accessory tool to begin cleaning. STEP 3 STEP 4 STEP 1 STEP 2 Use only one of the followin...
Page 9 - TECHNICAL SPECIFICATIONS; ELECTRIC VACUUM MOTOR:; GENERAL DIMENSIONS/WEIGHT
TECHNICAL SPECIFICATIONS CADET 86038340 04/19/07 3-1ENG POWER TYPE ELECTRICAL: 230-240 V, 7 A, 50 HZ ELECTRIC VACUUM MOTOR: (1) –3 stage, 1 hp, 99 cfm (2.80 cubic meters/min.) Waterlift –117” (297cm) BRUSH: (1) 15” (38.1 cm.) SOLUTION PUMP: 100 PSI, diaphragm style, internal bypass SOLUTION CAPACITY...
Page 10 - CONTROLS/COMPONENT LOCATIONS; Brush Motor Circuit Breaker.
CONTROLS/COMPONENT LOCATIONS CADET 86038340 04/19/07 3-2ENG 1. Main Handle. Used to pull and maneuver machine. 2. Electrical Cord. 3. Pump Switch. Turns on pump and enables spray. 4. Brush/Spray switch. Turns on brush motor and activates electro-valve to dispense solution to floor through jets. Inte...
Page 11 - Solution Accessory Tool Hookup.
CONTROLS/COMPONENT LOCATIONS CADET 86038340 04/19/07 3-3ENG 1 2 3 10 9 1. Solution Accessory Tool Hookup. Used for various auxiliary cleaning tools. 2. Vacuum Hose Door. Used to connect various auxiliary 1-1/2 inch cleaning tool vacuum hoses. 3. Brush Height Adjustment. Used to regulate brush height...
Page 12 - Solution Intake Cover.
CONTROLS/COMPONENT LOCATIONS CADET 86038340 04/19/07 3-4ENG 1. Solution Intake Cover. 2. Vacuum Intake Cover. 3. Float Shut-Off. 4. Clean-Out Opening. 5. Pour Spout. 6. Lift Handle. 2 1 3 4 5 6 6
Page 13 - FILLING OPERATIONS; FILLING THE CADET; RECOVERY TANK
FILLING OPERATIONS CADET 86038340 04/19/07 3-5ENG FILLING THE CADET NOTE: Use clean bucket of water to fill solution tank Do not put defoamer, solvents, spotter or prespray chemicals in the solution tank . Do not allow water to spill into vacuum motor inlet. Dry spillage from top of solution tank be...
Page 14 - OPERATIONS; Adjust brush to proper setting.; CORRECT; INCORRECT
OPERATIONS CADET 86038340 04/19/07 3-6ENG Remove electrical cord and literature from recovery tank. Fill solution tank (see filling operations, page 3-5). Adjust brush to proper setting. Note: For good operation the brush must skim the carpet. If circuit breaker trips raise brush to prevent damage t...
Page 15 - Lower machine to floor.
OPERATIONS CADET 86038340 04/19/07 3-7ENG Select intermittent or continuous switch setting to turn on brush and start solution spray. The intermittent setting requires the operator to hold the switch in the “on” position with the thumb, and is typically used in small areas where short cleaning passe...
Page 16 - CLEANING PROCEDURE; shut down the; OFF
CLEANING PROCEDURE CADET 86038340 04/19/07 3-8ENG 1ft. (30cm) Release intermittent setting or turn off continuous setting on brush/spray switch approximately 1 foot before ending cleaning pass. Push down on handle to raise vacuum shoe and brush before moving to the next cleaning pass. Overlap brush ...
Page 18 - MAINTENANCE; DAILY / REGULAR MAINTENANCE
MAINTENANCE CADET 86038340 04/19/07 4-1ENG PERIODIC MAINTENANCE Twice a month, flush a white vinegar solution (One quart vinegar to two gallons of water) or anti-browning solution (mixed as directed) through the extractor. This will prevent build-up of alkaline residue in the system. If spray jets b...
Page 19 - TO PERFORM THE FOLLOWING REPAIRS.; VACUUM MOTOR REPLACEMENT
MAINTENANCE CADET 86038340 04/19/07 4-2ENG ! WARNING: ONLY QUALIFIED MAINTENANCE PERSONNEL ARE TO PERFORM THE FOLLOWING REPAIRS. VACUUM MOTOR REPLACEMENT 1. Turn off all switches and unplug machine. 2. Remove recovery tank. 3. Remove the (2) screws that fasten the solution tank to the frame, and til...
Page 20 - BELT REPLACEMENT; SOLUTION PUMP REPLACEMENT
MAINTENANCE CADET 86038340 04/19/07 4-3ENG ! WARNING: BELT REPLACEMENT 1. Turn off all switches and unplug machine. 2. Remove recovery tank and brush. 3. Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the inside of the frame. 4. Loosen the (4) screws t...
Page 21 - TROUBLESHOOTING CHART; PROBLEM CAUSE
TROUBLESHOOTING CHART CADET 86038340 04/19/07 4-4ENG PROBLEM CAUSE SOLUTION No Power, Nothing Runs 1. Is the cord plugged in. 2. Circuit breaker tripped in building. 3. Faulty switch. 4. Faulty power cord or pigtail. 1. Plug in cord. 2. Reset breaker 3. Call for service. 4. Call for service. Vacuum ...
Page 22 - WIRING DIAGRAM
WIRING DIAGRAM CADET 86038340 04/19/07 4-5ENG 86268750 PRV NO. 88567 86268750 PRV NO. 88567 86268750 PRV NO. 88567 86268750 PRV NO. 88567 86268350 PRV NO. 88270 86003650 PRV NO. 34362 86001240 PRV NO. 14020 86268900 PRV NO. 88655 86268900 PRV NO. 88655 8600 448 0 PRV NO . 41 35 3
Page 23 - NOTES