White Rodgers 829A-845 - Manual

White Rodgers 829A-845

White Rodgers 829A-845 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
Page: / 6

Table of Contents:

  • Page 2 – WIRING; DIAGRAM FOR BOILER WITH DOMESTIC COIL WITH STORAGE TANK; NOTE
  • Page 3 – DIAGRAM FOR BOILER WITH TANKLESS DOMESTIC COIL; If excessive boiler temperature causes high limit to open,; The other terminal then goes to ZR.; DIAGRAM FOR MULTIZONE HYDRONIC HEATING SYSTEM
  • Page 4 – DESCRIPTION; RELAIS; INSTRUCTIONS D’INSTALLATION; PRÉCAUTIONS; ATTENTION; AVERTISSEMENT; SPÉCIFICATIONS
  • Page 5 – SCHÉMA POUR UNE CHAUDIÈRE SANS SERPENTIN DOMESTIQUE
  • Page 6 – systèmes alimentés à gaz; *La borne no 4 ou no 6 peut être reliée à la zone 2; SCHÉMA POUR SYSTÈMES DE CHAUFFAGE HYDRONIQUES À PLUSIEURS ZONES
Loading the manual

WHITE-RODGERS

T

T

1

2

3

4

5

6

Printed in U.S.A.

PART NO. 37-2689D

Replaces 37-2689-3

9512

TYPE 829A-845

RELAY

For Use With Low Voltage Thermostats

INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS RD., ST. LOUIS, MO. 63123
(314) 577-1300,

FAX (314) 577-1517

9999 HWY. 48, MARKHAM, ONT. L3P 3J3
(905) 475-4653, FAX (905) 475-4625

R

DESCRIPTION

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.

Type 829A-845 Relay has double-pole, single-throw
switching action.

This relay is especially suitable for use on hot water
heating installations having forced circulation. It permits
the use of a sensitive low voltage room thermostat to
control the operation of both burner and circulator.

It is equally well suited for use on zoned hot water
installations where a circulator and low voltage thermostat
are used for each zone.

ELECTRICAL DATA
Switch Action:
Double-Pole, Single-Throw, normally open
Input Voltage: Terminals (1 & 2) 120V.A.C., 60Hz
Room Thermostat:

Set adjustable heat anticipator at 0.3 Amps. For fixed
anticipation thermostats, use 0.25 to 0.35 Amp. heater.

Rating:

Terminals (3 & 4 and 5 & 6)

Total load must not exceed 2000 VA.
Motor:
120V.A.C.

10F.L.A.

60L.R.A.

240V.A.C.

6F.L.A.

36L.R.A.

Pilot Duty:50VA @ 24 Volts

SPECIFICATIONS

To prevent electrical shock and/or equipment
damage, disconnect electric power to system, at
main fuse or circuit breaker box, until installation
is complete.

If in doubt about whether your wiring is millivolt, line, or
low voltage, have it inspected by a qualified heating and
air conditioning contractor, electrician, or someone famil-
iar with basic electricity and wiring.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical
codes and ordinances.

This control is a precision instrument, and should be
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.

PRECAUTIONS

CAUTION

Do not use on circuits exceeding specified
voltages. Higher voltages will damage control
and could cause shock or fire hazard.

WARNING

PRINCIPLE OF OPERATION

The 829A-845 relay is provided with a self-contained
transformer with a low voltage secondary output for
energizing the relay coil.

Line voltage lines should be connected to the terminals
marked “1 & 2” for power to reach the transformer.

Closing the thermostat circuit energizes the relay coil which
in turn closes the circuits between terminals 3 and 4 and also
between 5 and 6.

Opening the thermostat circuit de-energizes the relay coil,
breaking the circuits between terminals 3 and 4 and also
between 5 and 6.

DOTTED LINES

INDICATE FIELD

WIRING

Fig. 1

RELAY
COIL

N

LINE

HOT

TO LINE AND LOAD

OR PILOT DUTY

TO LINE AND LOAD

OR PILOT DUTY

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - WIRING; DIAGRAM FOR BOILER WITH DOMESTIC COIL WITH STORAGE TANK; NOTE

2 X X X X T 1 4 2 3 T 5 6 WIRING All wiring should be done in accordance with local and national electrical codes and ordinances. When using this relay to control both line and low voltageloads, wires must be formed so that low voltage wires donot touch line voltage terminals and line voltage wiresm...

Page 3 - DIAGRAM FOR BOILER WITH TANKLESS DOMESTIC COIL; If excessive boiler temperature causes high limit to open,; The other terminal then goes to ZR.; DIAGRAM FOR MULTIZONE HYDRONIC HEATING SYSTEM

3 WIRING CONT. DIAGRAM FOR BOILER WITH TANKLESS DOMESTIC COIL X X T 1 4 2 3 T 5 6 X X TRANS. HIGH LIMIT 24 VAC GAS VALVE Fig. 5a & 6a Diagram for Gas-Fired System THERMOSTAT TYPE 668 OIL BURNER CONTROL (LINE VOLTAGE) HOT LINE N TYPE 11B05 CIRCULATOR CONTROL BURNER MOTOR CIRCULATOR MOTOR IGNITION...

Page 4 - DESCRIPTION; RELAIS; INSTRUCTIONS D’INSTALLATION; PRÉCAUTIONS; ATTENTION; AVERTISSEMENT; SPÉCIFICATIONS

WHITE-RODGERS T T 1 2 3 4 5 6 Imprimé aux É.-U.A. PIÈCE NO 37-2689D Remplace 37-2689-3 9512 WHITE-RODGERS DIVISIONEMERSON ELECTRIC CO.9797 REAVIS RD., ST. LOUIS, MO. 63123(314) 577-1300, Télécopieur (314) 577-1517 9999 HWY. 48, MARKHAM, ONT. L3P 3J3(905) 475-4653, Télécopieur (905) 475-4625 R DESCRI...

Other White Rodgers Models

All White Rodgers Other