White Rodgers 758-1 - Manual

White Rodgers 758-1

White Rodgers 758-1 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
Page: / 6

Table of Contents:

  • Page 2 – SETTING THE DIAL; Wiring; INSTALLATION
  • Page 3 – DESCRIPTION; Commande de ventilateur 757-1; INSTRUCTIONS D’INSTALLATION; CARACTÉRISTIQUES ÉLECTRIQUES GÉNÉRALES :; WARNING; AVERTISSEMENT
  • Page 4 – RÉGLAGE DU CADRAN; Branchements
  • Page 5 – DESCRIPCION; Control del Ventilador 757-1; INSTRUCCIONES DE INSTALACION; CAPACIDADES ELECTRICAS:; Operador: ¡Guarde estas instrucciones para usarlas en el futuró!; ADVERTENCIA
  • Page 6 – AJUSTE DEL DIAL; Cableado; INSTALACION
Loading the manual

To prevent electrical shock and/or equipment
damage, disconnect electric power to system at
main fuse or circuit breaker box until installation
is complete.

Label all wires prior to disconnection when ser-
vicing controls. Wiring errors can cause improper
and dangerous operation.

Following installation or replacement, follow
appliance manufacturers’ recommended instal-
lation/service instructions to insure proper op-
eration.

PART NO. 37-5788A

9721

Printed in U.S.A.

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.

DESCRIPTION

WHITE-RODGERS

757-1 Fan Control

758-1 Limit Control

INSTALLATION INSTRUCTIONS

The Fan control is a normally open SPST switch which
closes on a rise in temperature and has an adjustable
temperature setting.

The Limit control is a normally closed SPST switch which
opens on a rise in temperature to limit the maximum
allowable temperature and has an adjustable tempera-
ture setting.

Operator: Save these instructions for future use!

PRECAUTIONS

THIS CONTROL MUST BE INSTALLED BY A QUALI-
FIED INSTALLER.

All wiring must conform to local and national electrical
codes and ordinances.

This control is a precision instrument, and should be
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.

This control has been accurately calibrated at the factory.
Any attempt to re-calibrate this control will void the White-
Rodgers warranty.

Do not use on circuits exceeding specified volt-
ages. Higher voltages will damage control and
could cause shock or fire hazard.

If in doubt about whether your wiring is millivolt,
low or line voltage, have it inspected by a quali-
fied heating and air conditioning contractor or a
licensed electrician.

CAUTION

!

This control is particularly well suited for use where space
limitations are a problem. The small bimetal sensing
element is completely in the air stream to give quick
response. This control has a snap-action switch with
heavy duty contacts.

WARNING

!

SPECIFICATIONS

AC ELECTRICAL RATINGS:

8 Amps at 120 VAC or 4 Amps at 240 VAC
Pilot Duty: 125 VA

Temperature Ratings:

Fan control - Variable 70

°

to 160

°

F (21

°

to 71

°

C).

Fixed differential 25

°

F (14

°

C)

Limit control - Variable 110

°

to 200

°

F (43

°

to 93

°

C).

Fixed differential 25

°

F (14

°

C)

WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SETTING THE DIAL; Wiring; INSTALLATION

SETTING THE DIAL Wiring All wiring must conform to local and national electrical codes and ordinances. Follow the original equipment manufacturer's recommendations for proper wiring. Adjust temperature setting by inserting a screwdriver intoopen slot and turning pointer to desired temperature ondial...

Page 3 - DESCRIPTION; Commande de ventilateur 757-1; INSTRUCTIONS D’INSTALLATION; CARACTÉRISTIQUES ÉLECTRIQUES GÉNÉRALES :; WARNING; AVERTISSEMENT

No. DE PIÈCE 37-5788A 9721 Imprimé aux États-Unis DESCRIPTION WHITE-RODGERS Commande de ventilateur 757-1 Commutateur de seuil 758-1 INSTRUCTIONS D’INSTALLATION La commande de ventilateur est un commutateur-disjoncteur unipolaire ouvert au repos dont la fermetureest déclenchée par une augmentation d...

Page 4 - RÉGLAGE DU CADRAN; Branchements

RÉGLAGE DU CADRAN Branchements Tous les branchements doivent être conformes aux codes et règlements électriques locaux et nationaux. Suivez les recommandations de câblage du fabricant. Ajustez le réglage de température en enfonçant untournevis dans la fente et en tournant l’indicateur jusqu’àla temp...

Other White Rodgers Models