White Rodgers 700 - Manual

White Rodgers 700

White Rodgers 700 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
Page: / 6

Table of Contents:

  • Page 2 – MOUNTING AND WIRING; CAUTION; REMOVING OLD THERMOSTAT; CONTINUED FROM FIRST PAGE; WARNING; TERMINAL CROSS REFERENCE CHART; Electric Heat or Single-Stage
  • Page 3 – CHECK THERMOSTAT OPERATION; Figure 2. Typical wiring diagram for; Figure 3. Typical wiring diagram for; Figure 4. Typical wiring diagram for; Figure 5. Typical wiring diagram for; Figure 6. Typical wiring diagram for heat pump; Figure 7. Typical wiring diagram for heat pump; NOTE; Fan Operation; F, DO NOT operate the; Cooling System; CONTINUED FROM SECOND PAGE
  • Page 4 – CONTINUED FROM THIRD PAGE; The Thermostat Buttons and Switches; C CONVERTIBILITY — The factory default setting is
  • Page 5 – No Heat; SPECIFICATIONS; Operating Ambient Temperature Range:; TROUBLESHOOTING
  • Page 6 – CONTINUED FROM FIFTH PAGE
Loading the manual

CONTENTS

Preparations .................................................. 1

Thermostat Details ........................................ 1

Removing Old Thermostat ............................ 1

Mounting and Wiring ..................................... 2

Check Thermostat Operation ........................ 3

Specifications ................................................ 5

Troubleshooting ............................................ 5

PREPARATIONS

THERMOSTAT DETAILS

REMOVING OLD THERMOSTAT

Before removing wires from old thermostat’s switching subbase,
label each wire with the terminal designation it was removed from.

1. Remove Old Thermostat: A standard heat/cool thermostat

consists of three basic parts:

a. The cover, which may be either a snap-on or hinge type.

b. The base, which is removed by loosening all captive screws.

c. The switching subbase, which is removed by unscrewing

the mounting screws that hold it on the wall or adaptor plate.

2. Shut off electricity at the main fuse box until installation is

complete. Ensure that electrical power is disconnected.

3. Remove the front cover of the old thermostat. With wires still

attached, remove wall plate from the wall. If the old thermostat
has a wall mounting plate, remove the thermostat and the wall
mounting plate as an assembly.

4. Identify each wire attached to the old thermostat using the

labels enclosed with the new thermostat.

5. Disconnect the wires from the old thermostat one at a time. DO

NOT LET WIRES FALL BACK INTO THE WALL.

6. Install new thermostat using the following procedures.

To prevent electrical shock and/or equipment damage,
disconnect electrical power to the system at the main
fuse or circuit breaker until installation is complete.

CAUTION

!

Failure to follow and read all instructions carefully
before installing or operating this control could cause
personal injury and/or property damage

Assemble tools required as shown below.

YOUR THERMOSTAT REPLACES

1

2

3

WIRE CUTTER/STRIPPER

W

RH

B

RC

G

O

Y

+

-

+

-

GAS

ELEC

W 904

W 905

Figure 1. Thermostat base

Mounting

hole

Mounting

hole

W905

Clip for

Hydronic

System

W904

Clip for

Celsius Display

Electric/Gas

Switch

HAND OR POWER
DRILL WITH 3/16 INCH
DRILL BIT, IF NEEDED

FLAT BLADE SCREWDRIVER

Installation Instructions for

Digital Heating & Cooling

Model 700

Non-Programmable Thermostat

WHITE-RODGERS
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398
www.white-rodgers.com

PART NO. 37-6318C

Replaces 37-6318B

0435

Description

700

Standard Heat & Cooling Systems – 4 or 5 wires

Yes

Standard Heat Only Systems

Yes

Millivolt Heat Only Systems – Floor or Wall Furnaces

Yes

Standard Central Air Conditioning

Yes

Gas or Oil Heat

Yes

Electric Furnace

Yes

Hydronic (Hot Water) Zone Heat – 2 Wires

Yes

Hydronic (Hot Water) Zone Heat – 3 Wires

No

Heat Pump (No Aux or Emergency Heat)

Yes

Heat Pump (with Aux or Emergency Heat)

No

Baseboard Electric Heating or Line Voltage (120 or 240 volt)

No

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - MOUNTING AND WIRING; CAUTION; REMOVING OLD THERMOSTAT; CONTINUED FROM FIRST PAGE; WARNING; TERMINAL CROSS REFERENCE CHART; Electric Heat or Single-Stage

MOUNTING AND WIRING Take care when securing and routing wires so they donot short to adjacent terminals or rear of thermostat.Personal injury and/or property damage may occur. CAUTION ! ATTENTION! This product does not contain mercury. How-ever, this product may replace a unit which contains mercury...

Page 3 - CHECK THERMOSTAT OPERATION; Figure 2. Typical wiring diagram for; Figure 3. Typical wiring diagram for; Figure 4. Typical wiring diagram for; Figure 5. Typical wiring diagram for; Figure 6. Typical wiring diagram for heat pump; Figure 7. Typical wiring diagram for heat pump; NOTE; Fan Operation; F, DO NOT operate the; Cooling System; CONTINUED FROM SECOND PAGE

CHECK THERMOSTAT OPERATION www.white-rodgers.com 5 RH 24 VAC 120 VAC Hot Neutral THERMOSTAT SYSTEM G W Figure 2. Typical wiring diagram for heat only, 3-wire, single transformer systems TRANSFORMER Heating System Fan Relay Y RC JUMPER WIRE O B For 2-wire Heat only, attach to RH and W NOTE RH Y 24 VA...

Page 4 - CONTINUED FROM THIRD PAGE; The Thermostat Buttons and Switches; C CONVERTIBILITY — The factory default setting is

CHECK THERMOSTAT OPERATION CONTINUED FROM THIRD PAGE www.white-rodgers.com Before you begin using your thermostat, you should be familiarwith its features and with the display and the location andoperation of the thermostat buttons. Your thermostat consists oftwo parts: the thermostat cover and the ...