50A55-438

Integrated Furnace Control

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.

PART NO. 37-6102B

Replaces 37-6102A

0009

DESCRIPTION

INSTALLATION INSTRUCTIONS

The 50A55-438 is an automatic gas interrupted ignition control
that employs a microprocessor to continually monitor, analyze,
and control the proper operation of the gas burner, inducer, and
fan.

Signals interpreted during continual surveillance of the thermo-
stat and flame sensing element initiate automatic ignition of the
burner, sensing of the flame, and system shut-off during normal
operation.

WHITE-RODGERS

PRECAUTIONS

Operator: Save these instructions for future use!

These controls incorporate system fault analysis for quick gas
flow shut-off, coupled with automatic ignition retry upon sensing
a fault correction.

WARNING

Failure to comply with the following
warnings could result in personal injury
or property damage.

CAUTION

CONTENTS

Description ............................................................. 1
Precautions ............................................................ 1
Specifications ......................................................... 2
Installation .............................................................. 3

Mounting & Wiring

Operation ............................................................... 6
Mounting Hole Template ........................................ 8

Installation should be done by a qualified heating and air
conditioning contractor or licensed electrician.

If in doubt about whether your wiring is millivolt, line, or low
voltage, have it inspected by a qualified heating and air condi-
tioning contractor or licensed electrician.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes and
ordinances.

This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.

Following installation or replacement, follow manufacturer’s
recommended installation/service instructions to ensure proper
operation.

FIRE HAZARD

• Do not exceed the specified voltage.
• Replace existing control with exact model and

dash number.

• Protect the control from direct contact with water

(dripping, spraying, rain, etc.).

• If the control has been in direct contact with water,

replace the control.

• Label all wires before disconnection when servic-

ing controls. Wiring errors can cause improper
and dangerous operation.

• Route and secure wiring away from flame.

SHOCK HAZARD

• Disconnect electric power before servicing.
• Ensure proper earth grounding of appliance.
• Ensure proper connection of line neutral and line

hot wires.

EXPLOSION HAZARD

• Shut off main gas to appliance until installation is

complete.

Do not short out terminals on gas valve or primary
control. Short or incorrect wiring may damage the
thermostat.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SPECIFICATIONS

2 SPECIFICATIONS ELECTRICAL RATINGS [@ 77 ° F (25 ° C)]: Input Voltage: 25 VAC, 50/60 Hz Max. Input Current @ 25 VAC: 0.45 amp Relay Load Ratings: Valve Relay: 1.5 amp @ 25 VAC, 50/60 Hz, 0.6 pfIgnitor Relay: 6.0 amp @120 VAC, 50/60 Hz, (resistive) Flame Current Requirements: Minimum current to insu...

Page 3 - INSTALLATION; WARNING; CAUTION; MOUNTING AND WIRING

3 INSTALLATION WARNING CAUTION FIRE HAZARD • Do not exceed the specified voltage.• Replace existing control with exact model and dash number. • Protect the control from direct contact with water (dripping, spraying, rain, etc.). • Label all wires before disconnection when servic- ing controls. Wirin...

Page 6 - OPERATION; OPTION SWITCHES

6 OPERATION COOL delay- to-fan-off: Set switch #1 COOL delay- to-fan-off: Set switch #2 #3 0 sec. 80 sec. OnOff 60 sec. 100 sec.140 sec.180 sec. On OffOn OnOff OnOff Off OPTION SWITCH POSITIONS OPTION SWITCHES The option switches on the 50A55-438 control are used todetermine the length of the cool d...