White Rodgers 37-7237A - Manual
White Rodgers 37-7237A – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Remove Old Thermostat; WIRING CONNECTIONS
- Page 3 – WIRING DIAGRAMS; Heat Pump Connections; Single Stage and Multi-Stage Connections
- Page 4 – THERMOSTAT QUICK REFERENCE; Home Screen Description; Set
- Page 5 – INSTALLER/CONFIGURATION MENU; MENU; Select System Switch Configuration
- Page 7 – OPERATING YOUR THERMOSTAT; Choose the System Setting; Second Stage Time Delay; TROUBLESHOOTING
- Page 8 – Reset Operation; When thermostat is reset, installer configuration menu; Symptom; No Heat
- Page 9 – SOLUCIÓN DE PROBLEMAS; Operación de reajuste; Síntoma; odger
- Page 12 – MENÚ INST ALADOR/DE CONFIGURA
- Page 13 – GUÍA DE REFERENCIA RÁPIDA DEL; Descripción de la pantalla
- Page 14 – DIAGRAMA DE CONEXIONES
- Page 15 – Cómo retirar el termostato viejo; CONEXIONES ELÉCTRICAS
- Page 16 – ¡Conserve estas instrucciones para; APLICACIONES
1
Blue 4” Universal Thermostat with
Automatic Heat/Cool Changeover Option
Single Stage, Multi-Stage or Heat Pump
Installation and Operating Instructions for Model:
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING
THIS CONTROL COULD CAUSE PERSONAL INJURY
AND/OR PROPERTY DAMAGE.
Save these instructions for future use!
APPLICATIONS
SPECIFICATIONS
Electrical Rating:
Battery Power .................................................... mV to 30 VAC, NEC Class II, 50/60 Hz or DC
Input-Hardwire ................................................... 20 to 30 VAC
Terminal Load ........................................................... 1.5 A per terminal, 2.5A maximum all terminals combined
Setpoint Range ......................................................... 45° to 90°F (7° to 32°C)
Rated Differentials: Fast
Med.
Slow
Heat (Single Stage/Multi Stage) ........................ 0.4 °F
0.6 °F
1.7 °F
Cool (Single Stage/Multi Stage) ........................ 0.9 °F
1.2 °F
1.7 °F
Heat Pump ......................................................... 0.9 °F
1.2 °F
1.7 °F
Aux. Heat ........................................................... 0.6 °F
–
1.7 °F
Operating Ambient .................................................... 32° to +105°F (0° to +41°C)
Operating Humidity ................................................... 90% non-condensing max.
Shipping Temperature Range ................................... -40° to +150°F (-40° to +65°C)
Dimensions Thermostat ............................................ 3-7/8”H x 5-1/8”W x 1-1/4”D
1F83-0471 Thermostat
Model
Programming Choice
1F83-0471
Non-Programmable
ATTENTION: MERCURY NOTICE
This product does not contain mercury. However, this product
may replace a product that contains mercury.
Mercury and products containing mercury must not be
discarded in household trash. Do not touch any spilled
mercury. Wearing non-absorbent gloves, clean up any
spilled mercury and place in a sealed container. For proper
disposal of a product containing mercury or a sealed
container of spilled mercury, place it in a suitable shipping
container. Refer to
www.white-rodgers.com
for location to
send product containing mercury.
To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.
CAUTION
!
THERMOSTAT APPLICATION GUIDE
Description
Heat Pump (No Aux. or Emergency Heat)
Yes
Heat Pump (with Aux. or Emergency Heat)
Yes
Systems with up to 2 Stages Heat, 2 Stages Cool
Yes
Heat Only Systems (with optional fan switch)
Yes
Millivolt Heat Only Systems – Floor or Wall Furnaces
Yes
Cool Only Systems
Yes
Gas or Oil Heat
Yes
Electric Furnace
Yes
Hydronic (Hot Water) Zone Heat – 2 Wires
Yes
Hydronic (Hot Water) Zone Heat – 3 Wires
Yes
Compressor with Comfort Alert II Module (1F85CA only)
Yes
Index
Page
Installation
2
Wiring Connections
2
Wiring Diagrams
3
Thermostat Quick Reference
4
Installer Configuration Menu
5
Operating Your Thermostat
7
Troubleshooting
7
www.white-rodgers.com
www.emersonclimate.com
PART NO. 37-7237A
1117
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 INSTALLATION Thermostat installation and all components of the control system shall conform to Class II circuits per the NEC code. WARNING ! Remove Old Thermostat A standard heat/cool thermostat consists of three basic parts:1. The cover, which may be either a snap-on or hinge type.2. The base, wh...
3 WIRING DIAGRAMS Heat Pump Connections If you do not have a heat pump system, refer to figures 4-6. Refer to equipment manufacturers’ instructions for specific system wiring information. You can configure the thermostat for use with the following heat pump systems. Figure 3 – Heat Pump Systems HEAT...
4 Set SYSTEM Heat FAN Auto Menu RoomTemperature SettingTemperature SystemIndicator FanIndicator Displays the power level ofthe 2 “AA” batteries: indicates good power level indicates batteries at abouthalf power. “ Change ” indicates batteries are low and should be replaced with 2 new premium brand “...