White Rodgers 37-7237A - Manual

White Rodgers 37-7237A

White Rodgers 37-7237A – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
Page: / 16

Table of Contents:

  • Page 2 – Remove Old Thermostat; WIRING CONNECTIONS
  • Page 3 – WIRING DIAGRAMS; Heat Pump Connections; Single Stage and Multi-Stage Connections
  • Page 4 – THERMOSTAT QUICK REFERENCE; Home Screen Description; Set
  • Page 5 – INSTALLER/CONFIGURATION MENU; MENU; Select System Switch Configuration
  • Page 7 – OPERATING YOUR THERMOSTAT; Choose the System Setting; Second Stage Time Delay; TROUBLESHOOTING
  • Page 8 – Reset Operation; When thermostat is reset, installer configuration menu; Symptom; No Heat
  • Page 9 – SOLUCIÓN DE PROBLEMAS; Operación de reajuste; Síntoma; odger
  • Page 12 – MENÚ INST ALADOR/DE CONFIGURA
  • Page 13 – GUÍA DE REFERENCIA RÁPIDA DEL; Descripción de la pantalla
  • Page 14 – DIAGRAMA DE CONEXIONES
  • Page 15 – Cómo retirar el termostato viejo; CONEXIONES ELÉCTRICAS
  • Page 16 – ¡Conserve estas instrucciones para; APLICACIONES
Loading the manual

1

Blue 4” Universal Thermostat with

Automatic Heat/Cool Changeover Option

Single Stage, Multi-Stage or Heat Pump

Installation and Operating Instructions for Model:

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING
THIS CONTROL COULD CAUSE PERSONAL INJURY
AND/OR PROPERTY DAMAGE.

Save these instructions for future use!

APPLICATIONS

SPECIFICATIONS

Electrical Rating:

Battery Power .................................................... mV to 30 VAC, NEC Class II, 50/60 Hz or DC

Input-Hardwire ................................................... 20 to 30 VAC
Terminal Load ........................................................... 1.5 A per terminal, 2.5A maximum all terminals combined
Setpoint Range ......................................................... 45° to 90°F (7° to 32°C)
Rated Differentials: Fast

Med.

Slow

Heat (Single Stage/Multi Stage) ........................ 0.4 °F

0.6 °F

1.7 °F

Cool (Single Stage/Multi Stage) ........................ 0.9 °F

1.2 °F

1.7 °F

Heat Pump ......................................................... 0.9 °F

1.2 °F

1.7 °F

Aux. Heat ........................................................... 0.6 °F

1.7 °F

Operating Ambient .................................................... 32° to +105°F (0° to +41°C)
Operating Humidity ................................................... 90% non-condensing max.
Shipping Temperature Range ................................... -40° to +150°F (-40° to +65°C)
Dimensions Thermostat ............................................ 3-7/8”H x 5-1/8”W x 1-1/4”D

1F83-0471 Thermostat

Model

Programming Choice

1F83-0471

Non-Programmable

ATTENTION: MERCURY NOTICE

This product does not contain mercury. However, this product
may replace a product that contains mercury.

Mercury and products containing mercury must not be
discarded in household trash. Do not touch any spilled
mercury. Wearing non-absorbent gloves, clean up any
spilled mercury and place in a sealed container. For proper
disposal of a product containing mercury or a sealed
container of spilled mercury, place it in a suitable shipping
container. Refer to

www.white-rodgers.com

for location to

send product containing mercury.

To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.

CAUTION

!

THERMOSTAT APPLICATION GUIDE

Description

Heat Pump (No Aux. or Emergency Heat)

Yes

Heat Pump (with Aux. or Emergency Heat)

Yes

Systems with up to 2 Stages Heat, 2 Stages Cool

Yes

Heat Only Systems (with optional fan switch)

Yes

Millivolt Heat Only Systems – Floor or Wall Furnaces

Yes

Cool Only Systems

Yes

Gas or Oil Heat

Yes

Electric Furnace

Yes

Hydronic (Hot Water) Zone Heat – 2 Wires

Yes

Hydronic (Hot Water) Zone Heat – 3 Wires

Yes

Compressor with Comfort Alert II Module (1F85CA only)

Yes

Index

Page

Installation

2

Wiring Connections

2

Wiring Diagrams

3

Thermostat Quick Reference

4

Installer Configuration Menu

5

Operating Your Thermostat

7

Troubleshooting

7

www.white-rodgers.com

www.emersonclimate.com

PART NO. 37-7237A

1117

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Remove Old Thermostat; WIRING CONNECTIONS

2 INSTALLATION Thermostat installation and all components of the control system shall conform to Class II circuits per the NEC code. WARNING ! Remove Old Thermostat A standard heat/cool thermostat consists of three basic parts:1. The cover, which may be either a snap-on or hinge type.2. The base, wh...

Page 3 - WIRING DIAGRAMS; Heat Pump Connections; Single Stage and Multi-Stage Connections

3 WIRING DIAGRAMS Heat Pump Connections If you do not have a heat pump system, refer to figures 4-6. Refer to equipment manufacturers’ instructions for specific system wiring information. You can configure the thermostat for use with the following heat pump systems. Figure 3 – Heat Pump Systems HEAT...

Page 4 - THERMOSTAT QUICK REFERENCE; Home Screen Description; Set

4 Set SYSTEM Heat FAN Auto Menu RoomTemperature SettingTemperature SystemIndicator FanIndicator Displays the power level ofthe 2 “AA” batteries: indicates good power level indicates batteries at abouthalf power. “ Change ” indicates batteries are low and should be replaced with 2 new premium brand “...

Other White Rodgers Models

All White Rodgers Other